Paradigm®

Pump MMT-715LNAS Rohs Prdgm 2.3 SK EN LN

Registry build 21.09.26
7manufacturers in China registered for this device type
1catalogue number
15510(k) clearances naming this product code
19recalls on this code

Who Else Makes It

Concentrated in Jiangsu (3), Guangdong (3), Shanghai (1). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LZG
Manufacturer City Province Registered as Device types
Sanmina Kunshan Jiangsu Contract manufacturer 15
Providence Enterprise Limited Shenzhen Guangdong Contract manufacturer 9
Flextronics Industrial (Shenzhen) Co., Ltd. Shenzhen Guangdong Contract manufacturer 5
Advance Technology Ltd Shenzhen Guangdong Contract manufacturer 3
Sterigenics Shanghai ETO Ltd. Shanghai Shanghai Contract manufacturer 65
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Viant Medical Suzhou EPZ Co., Ltd. Jiangsu Jiangsu Contract manufacturer 3

Record

Regulatory record for Paradigm®
Listed by Medtronic Minimed, United States
FDA product code LZG
Device type Pump, Infusion, Insulin
Device class Class 2
Regulation 21 CFR 880.5725
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
510(k) K040676
Record published 2020-11-16

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries serial number

Catalogue Numbers

Catalogue numbers for Paradigm®
Catalogue number Size Status
MMT-715LNAS In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
OneTouch Ping Animas Corp. 12
Easy Release Sooil Development Co., Ltd. 9
V-Go Disposable Insulin Delivery Mannkind Corporation 6
Accu-Chek Combo Roche Diabetes Care, Inc. 5
Superline Sooil Development Co., Ltd. 4
t:slim Cartridge, t:lock, 10 Pack Tandem Diabetes Care, Inc. 3
Dana Diabecare Sooil Development Co., Ltd. 3
Accu-Chek Spirit Cartridge Roche Diabetes Care, Inc. 2
t:slim X2 Insulin Pump Tandem Diabetes Care, Inc. 2
Omnipod Insulet Corporation 2
Soft-Release-ST Sooil Development Co., Ltd. 2
t:slim Insulin Pump, Replacement Tandem Diabetes Care, Inc. 1

Showing 12 of 53. All products under Pump, Infusion, Insulin

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K241622 2024-07-02
K210714 2022-04-06
K120206 2012-03-29
K073356 2008-04-25
K053177 2006-01-31
K041318 2004-07-19
K041317 2004-07-19
K040676 2004-05-21
K032164 2003-10-23
K993012 1999-11-15
K990801 1999-06-08
K972107 1997-08-15
K963948 1997-04-08
K960001 1996-04-30
K901588 1990-07-02

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Paradigm®
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Medtronic Minimed 510(k) number 2026-02-13 Class II Device Design All Medtronic MiniMed infusion pumps (Paradigm series, 600 series, and BLE 700 series) were found to be affected by unintended over- and under-delivery of insulin when the pump is elevated or lowered relative to the infusion site, respectiv 73,656
Medtronic Minimed 510(k) number 2007-04-27 Not classified Other Exposure to Magnetic Resonance Imaging (MRI) has resulted in damage to the component that monitors and controls movement of the motor in the MiniMed Paradigm insulin infusion pump. Although there were alarms as a result of the damage, some 334,000 Paradigm insulin pumps (approx) 2012-09-19

Recalls

2 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-01-31 Class II Device Design All Medtronic MiniMed pumps (Paradigm series, Minimed 530G, 6XX series, and 7XX series) were found to have the potential for abnormal insulin delivery due to changes in air pressure, which can be found during airplane take-off or landing. 20,760 units
2019-06-27 Class II Device Design The action is being initiated due to potential cybersecurity vulnerabilities related to a series of insulin pumps that are designed to communicate using a wireless radio frequency (RF). An unauthorized person could potentially connect wirel 73,028
2019-06-27 Class II Device Design The action is being initiated due to potential cybersecurity vulnerabilities related to a series of insulin pumps that are designed to communicate using a wireless radio frequency (RF). An unauthorized person could potentially connect wirel 30,479
2019-06-27 Class II Device Design The action is being initiated due to potential cybersecurity vulnerabilities related to a series of insulin pumps that are designed to communicate using a wireless radio frequency (RF). An unauthorized person could potentially connect wirel 34,777
2019-06-27 Class II Device Design The action is being initiated due to potential cybersecurity vulnerabilities related to a series of insulin pumps that are designed to communicate using a wireless radio frequency (RF). An unauthorized person could potentially connect wirel 64,174 units
2019-06-27 Class II Device Design The action is being initiated due to potential cybersecurity vulnerabilities related to a series of insulin pumps that are designed to communicate using a wireless radio frequency (RF). An unauthorized person could potentially connect wirel 74,496
2019-06-27 Class II Device Design The action is being initiated due to potential cybersecurity vulnerabilities related to a series of insulin pumps that are designed to communicate using a wireless radio frequency (RF). An unauthorized person could potentially connect wirel 36,143
2018-08-07 Class I Software design There is a potential security vulnerability related to the use of the remote controller accessories with the insulin pumps. 90,213 2024-03-29
2018-08-07 Class I Software design There is a potential security vulnerability related to the use of the remote controller accessories with the insulin pumps. 141,519 2024-03-29
2014-11-10 Class III Software design The firm is informing customers of a software error that might result in an inaccurate display of the Temp Basal time and duration in CareLink Clinical reports with data uploaded from the MiniMed 620G or 640G insulin pump. 5 CareLink Pro 4.0 CD ROMs 2015-03-10
2005-04-27 Not classified Other The text description of how to perform insulin sensitivity testing and associated worksheet included in the booklet that is shipped with the Paradigm 515 and Paradigm 715 insulin pumps contained a basic flaw in that the blood glucose after Approximately 14,560 2007-03-20
2004-09-14 Not classified Other Several complaints of pumps exhibiting A47 alarms were received. Investigation revealed the alarms occurred when the pump attempted to display text that exceeded the maximum display length of the pump screen. The investigation revealed thi 10,600 2005-03-03
2004-09-14 Not classified Other Several complaints of pumps exhibiting A47 alarms were received. Investigation revealed the alarms occurred when the pump attempted to display text that exceeded the maximum display length of the pump screen. The investigation revealed thi 2005-03-03
2004-01-28 Not classified Other A minor software anomaly results in an error in the calculation of the average glucose range that appears on one of the reports available in the model 7311 software. 2005-01-18
2003-11-19 Not classified Other Accessory software fails to report certain reports following download of data from 712 pump. 1020 2005-03-03
2003-09-09 Not classified Other Non delivery of insulin by pump after electrostatic discharge. 17,000 2005-09-02
2003-08-29 Not classified Other Water ingresses into the device when in prolonged contact with water causing device to malfunction. Approximately 61,000 patients 2005-09-02

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer