System/Device, Pharmacy Compounding

Vented Solution Transfer Set, Large Bore Tubing and Two Spike Connectors

Registry build 21.09.26
2manufacturers in China registered for this device type
9catalogue numbers in this listing
8recalls on this code

Who Else Makes It

All of them in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code NEP
Manufacturer City Province Registered as Device types
Yangzhou Xingwei Medical Technology Co., Ltd. Yangzhou Jiangsu Contract manufacturer 5
Yangzhou Weideli Trading Co., Ltd. Yangzhou Jiangsu Contract manufacturer 10

Record

Regulatory record for System/Device, Pharmacy Compounding
Listed by Baxter Healthcare Corporation, United States
FDA product code NEP
Device type System/Device, Pharmacy Compounding
Device class Class 2
Regulation 21 CFR 880.5440
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2016-09-24
Record revised 2023-07-21 (version 9)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Packaging Case of 48
Distribution end date 2023-12-31

Catalogue Numbers

Catalogue numbers for System/Device, Pharmacy Compounding
Catalogue number Size Per pack Status
1C8592 In distribution
2C0430 In distribution
1C8189 In distribution
1C8624 In distribution
2C0415 In distribution
2B8045 1,000 Withdrawn
2C0426 Withdrawn
2C0463 Withdrawn
2B8044 1,000 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Exactamix Baxter Healthcare Corporation 27
ICU Medical, Inc. ICU Medical, Inc 16
Apex™ B. Braun Medical Inc. 15
Pinnacle® B. Braun Medical Inc. 13
DianaTM Compounding Workflow System ICU Medical, Inc 9
Repeater Baxter Healthcare Corporation 8
DianaTM Automated Drug Compounding System ICU Medical, Inc 5
Single Lead High Volume Pump Chamber SET MPS Pharma & Medical, Inc. 4
Abacus Baxter Healthcare Corporation 4
Apoteca AEA SRL 3
GRI-BAG Laboratorios Grifols SA 3
Exactamix Baxter Corporation Englewood 3

Showing 12 of 35. All products under System/Device, Pharmacy Compounding

Recalls

5 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-04-22 Class II Under Investigation by firm Affected lots may contain incorrect 0.8-micron filters. Use of a 0.8-micron filter in place of the validated 3-micron filter may lead to reduced flow efficiency, incomplete or slower transfers of ingredients, or system alarms. This issue ma 105675
2022-06-22 Class I Software design There is a potential risk of medication error when using specific Abacus Order Entry & Calculation software. 9 units 2024-10-09
2015-11-30 Class II Under Investigation by firm Potential for dark loose particulate matter (400 microns or smaller) on the spike of the spike adapter or solution set. 77,136 units 2016-10-30
2013-11-08 Class II Nonconforming Material/Component Following a retrospective review for Baxter Daytona Complaint CR-954, it was identified that the IntelliFill i.v. Pharmacy Compounding Device (PCD) (product code: IFIV) has the potential to continue to run and fill syringes with the HEPA fi 28 devices 2015-03-23
2012-07-13 Class I Device Design After fluid ingress into the keypad of the AUTOMIX Compounder’s (AUTOMIX) control module, the AUTOMIX may generate an incorrect device response to an AUTOMIX operator’s key press. Also, the AUTOMIX system may experience an intermittent ele 950 units 2017-08-11
2012-07-13 Class I Device Design After fluid ingress into the keypad of the AUTOMIX Compounder’s (AUTOMIX) control module, the AUTOMIX may generate an incorrect device response to an AUTOMIX operator’s key press. Also, the AUTOMIX system may experience an intermittent ele 3106 units 2017-08-11
2012-07-13 Class I Device Design After fluid ingress into the keypad of the AUTOMIX Compounder’s (AUTOMIX) control module, the AUTOMIX may generate an incorrect device response to an AUTOMIX operator’s key press. Also, the AUTOMIX system may experience an intermittent ele 270 units 2017-08-11
2012-07-13 Class I Device Design After fluid ingress into the keypad of the AUTOMIX Compounder’s (AUTOMIX) control module, the AUTOMIX may generate an incorrect device response to an AUTOMIX operator’s key press. Also, the AUTOMIX system may experience an intermittent ele 840 units 2017-08-11

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.