PowerGlide ST

3 catalogue numbers from PCK00013, listed by Bard Access Systems, Inc., United States, under Midline Catheter. 1 manufacturer in China is registered for this product code.

Registry build 21.09.26
1manufacturer
3catalogue numbers in this listing
3recalls on this code

Who Else Makes It

Registered in Zhejiang.

Chinese manufacturers registered for FDA product code PND
Manufacturer City Province Registered as Device types
Terumo Medical Products (Hangzhou) Co., Ltd. Hangzhou Zhejiang Contract manufacturer 7

Record

Regulatory record for PowerGlide ST
Listed by Bard Access Systems, Inc., United States
FDA product code PND
Device type Midline Catheter
Device class Class 2
Regulation 21 CFR 880.5200
Establishment Specification developer, Complaint-file establishment, Manufacturer, Exporter
Record published 2023-07-05

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date
Storage Storage environment temperature 20 to 25 °C
Packaging Case of 6
Sizes Needle gauge 18 to 20 G; length 8 to 10 cm

Catalogue Numbers

Catalogue numbers for PowerGlide ST
Catalogue number Size Status
PCK00013 Needle Gauge 18 G In distribution
PCK00015 Length 8 cm In distribution
PCK00014 Needle Gauge 18 G In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Midline Catheter Kit Bard Access Systems, Inc. 68
PowerMidline Bard Access Systems, Inc. 57
Vygon Vygon Corp. 36
Arrow Teleflex Medical LLC 33
Provena Midline Bard Access Systems, Inc. 31
Peripheral Catheter Insertion Kit Bard Access Systems, Inc. 20
primeMIDLINE PFM Medical, Inc 6
Provena Bard Access Systems, Inc. 5
BioFlo Navilyst Medical, Inc. 4
CT Midline Catheter Medical Components Inc 3
20G 8CM Stiletto Extended Dwell Catheter Avia Vascular 1
Arch-FLO CT Midlinearch-FLO CT Midline Medical Components Inc 1

Showing 12 of 14. All products under Midline Catheter

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2026-05-21 Class II Nonconforming Material/Component Due to lidocaine ampoules being manufactured under deficient manufacturing practices by manufacturer, lidocaine ampoules are currently being recalled by supplier. 24,348
2026-05-21 Class II Nonconforming Material/Component Due to lidocaine ampoules being manufactured under deficient manufacturing practices by manufacturer, lidocaine ampoules are currently being recalled by supplier. 16,887
2026-05-21 Class II Nonconforming Material/Component Due to lidocaine ampoules being manufactured under deficient manufacturing practices by manufacturer, lidocaine ampoules are currently being recalled by supplier. 2,844

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer