Tandem Mobi Autosoft XC Kit
Tandem Mobi AutoSoft XC Kit is a package of infusion sets for use with Tandem’s Mobi pump. Each AutoSoft XC set uses a flexible soft cannula inserted at a 90-degree angle, with tubing…
Tandem Mobi AutoSoft XC Kit is a package of infusion sets for use with Tandem’s Mobi pump. Each AutoSoft XC set uses a flexible soft cannula inserted at a 90-degree angle, with tubing connecting the set to the pump. An automatic insertion device is part of the set.
A large grip and reversible connector support disconnection, and a built-in needle cover is included. The manufacturer lists cannula lengths of 6 or 9 mm and several tubing options across the AutoSoft XC family; options differ by configuration.
Listed Item
Autosoft XC, 23″/13mm, 14 pack kit
Set Design
AutoSoft XC combines the insertion device, tubing, cannula and connector in one infusion-set design. The connector can be reversed, and the large grip is intended to make disconnection easier.
The listed Mobi kit is a specific package within the family. Its device identity is model 1015599; package-specific labeling determines the precise contents and selected tubing/cannula options.
Who Else Makes It
All of them in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Sanmina | Kunshan | Jiangsu | Contract manufacturer | 15 |
| Steris Sterilization Technologies (Suzhou) Ltd | Suzhou | Jiangsu | Contract manufacturer | 44 |
Record
| Listed by | Tandem Diabetes Care, Inc., United States |
|---|---|
| FDA product code | QFG |
| Device type | Alternate Controller Enabled Insulin Infusion Pump |
| Device class | Class 2 |
| Regulation | 21 CFR 880.5730 |
| Establishment | Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2024-06-21 |
| Record revised | 2025-04-09 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1014120 | In distribution | |
| 1014119 | In distribution | |
| 1013120 | In distribution | |
| 1013119 | In distribution | |
| 1013118 | In distribution | |
| 1018555 | In distribution | |
| 1015599 | In distribution | |
| 1018523 | In distribution | |
| 1018529 | In distribution | |
| 1015595 | In distribution | |
| 1018549 | In distribution | |
| 1015597 | In distribution | |
| 1014118 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| t:slim X2 Insulin Pump with Control-IQ+ Technology | Tandem Diabetes Care, Inc. | 12 |
| t:slim X2 Insulin Pump with Control-IQ | Tandem Diabetes Care, Inc. | 11 |
| t:slim X2 Insulin Pump with Basal-IQ | Tandem Diabetes Care, Inc. | 9 |
| Tandem Mobi | Tandem Diabetes Care, Inc. | 5 |
| MiniMed Flex | Medtronic Minimed | 4 |
| Tandem Mobi Autosoft 30 Kit | Tandem Diabetes Care, Inc. | 4 |
| Omnipod 5 Pod | Insulet Corporation | 3 |
| Tandem Mobi TruSteel Kit | Tandem Diabetes Care, Inc. | 3 |
| Tandem Mobi Cartridge | Tandem Diabetes Care, Inc. | 3 |
| MiniMed Flex Starter Kit | Medtronic, Inc. | 2 |
| Omnipod 5 Controller APP | Insulet Corporation | 2 |
| Tandem t:slim AutoSoft XC Kit | Tandem Diabetes Care, Inc. | 2 |
Showing 12 of 36. All products under Alternate Controller Enabled Insulin Infusion Pump
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K253074 | 2025-11-06 |
| K250792 | 2025-09-24 |
| K241078 | 2024-07-26 |
| K240309 | 2024-03-21 |
| K232380 | 2023-11-03 |
| K233044 | 2023-10-05 |
| K223213 | 2023-07-10 |
| K203234 | 2022-02-15 |
| K201214 | 2020-06-04 |
| DEN180058 | 2019-02-14 |
Recalls
5 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2026-01-30 | Class II | Process change control | The Czech language user guide contained multiple translation errors. The most significant error was that it incorrectly instructs users to verify that the infusion set is connected to the body, when it should instead direct users to confir | 1,380 units |
| 2025-10-06 | Class I | Software design | Insulin pump includes a vibration motor that gives tactile feedback for any alerts, alarms, or malfunctions. Pump may exhibit false vibration motor failure due to a software issue causing Malfunction 12: “Pump cannot operate, the mobile app | 17,745 |
| 2025-08-05 | Class II | Software change control | A software defect in versions 7.9.0.1 and 7.10.1 of the pump software for Tandem t:slim X2 and version 7.9.0.1 of the Tandem Mobi pump with Control-IQ+ technology that are paired with a G7 sensor may result in an unexpected automatic insuli | 122,958 |
| 2025-07-21 | Class I | Nonconforming Material/Component | Insulin pumps manufactured with speakers from Revision A and B may malfunction (“Malfunction 16”) which prevents audible alerts and causes the pumps to become inoperable and stop infusing insulin which could result in a hyperglycemic event, | 171,750 |
| 2025-07-03 | Class II | Software design | an app defect that occurs when the phone is set to a right-to-left language, which causes app-pump pairing issues and graphical defects, which can potentially lead to incorrect therapy decisions and subsequent hypoglycemia or hyperglycemia. | 19 |
| 2025-02-27 | Class I | Software Design Change | A software defect in Version 7.9 of the pump software for Tandem t:slim X2 and Tandem Mobi pumps, when used with Control IQ+ technology, will cause the pump to incorrectly interpolate glucose trends when the Estimated Glucose Value (EGV) is | 85 units |
| 2025-02-27 | Class I | Software Design Change | A software defect in Version 7.9 of the pump software for Tandem t:slim X2 and Tandem Mobi pumps, when used with Control IQ+ technology, will cause the pump to incorrectly interpolate glucose trends when the Estimated Glucose Value (EGV) is | 63 units |
| 2024-03-05 | Class I | Software Design Change | During normal use, the mobile app version 2.7 may crash and be automatically relaunched by the iOS operating system. This cycle intermittently repeats, which leads to excessive Bluetooth communication that may result in pump battery drain a | 85,863 applications |