Foot Switch

23 catalogue numbers from 100981J2, listed by Maquet Gmbh, Germany, under Table, Operating-Room, Ac-Powered. 11 manufacturers in China are registered for this product code.

Registry build 21.09.26
11manufacturers in China registered for this device type
23catalogue numbers in this listing
3recalls on this code

Who Else Makes It

Concentrated in Jiangsu (6), Shanghai (1), Anhui (1).

Chinese manufacturers registered for FDA product code FQO
Manufacturer City Province Registered as Device types
Jiangsu Saikang Medical Equipment Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 34
Jiangsu Yongfa Medical Equipment Technology Co., Ltd. Zhangjiagang Jiangsu Manufacturer 33
Shanghai NO. 2 Medical College Duhang Medical Equipment Factory Shanghai Shanghai Contract manufacturer 32
Jiangsu Rooe Medical Technology Co., Ltd. Zhangjiagang Jiangsu Manufacturer 31
Hefei MT Medical Co., Ltd. Hefei Anhui Manufacturer 23
Jiangsu Keling Medical Appliances Co., Ltd. Yangzhou Jiangsu Contract manufacturer 23
Hebei Jiede Medical Equipment Co., Ltd. Hengshui Hebei Contract manufacturer 20
Suzhou Number WIN Medical Technology Co., Ltd. Zhangjiagang Jiangsu Manufacturer 16
Shandong Deman Medical Equipment Group Co., Ltd. Jining Shandong Manufacturer 11
Nanchang Micare Medical Equipment Co., Ltd. Nanchang Jiangxi Manufacturer 8
Nanjing Mindray BIO-Medical Electronics Co., Ltd. Nanjing Jiangsu Manufacturer 2

Record

Regulatory record for Foot switch
Listed by Maquet Gmbh, Germany
FDA product code FQO
Device type Table, Operating-Room, Ac-Powered
Device class Class 1
Regulation 21 CFR 878.4960
Establishment Specification developer, Repacker / relabeller, Manufacturer
Premarket notification Exempt
Record published 2022-09-22

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Foot switch
Catalogue number Size Status
100981J2 In distribution
100981J0 In distribution
100981E3 In distribution
100981F0 In distribution
100981E2 In distribution
100981H1 In distribution
100981D2 In distribution
100981F3 In distribution
100981G1 In distribution
100981G0 In distribution
100981H0 In distribution
100981H2 In distribution
100981F1 In distribution
100982A0 In distribution
100981G2 In distribution
100981J1 In distribution
100981E0 In distribution
100981G3 In distribution
100981D0 In distribution
100981D1 In distribution
100981D4 In distribution
100981D3 In distribution
100981E1 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
HarmonyAIR Steris Corporation 452
Skytron Skytron, LLC 200
Table, Operating-Room, Ac-Powered Steris Corporation 165
iCE boom and Pendant Amico Clinical Solutions 102
Mindray Nanjing Mindray BIO-Medical Electronics Co., Ltd. 95
Amtai Amtai Medical Equipment, Inc. 95
Steris Steris Corporation 72
Alyon Steris Corporation 41
Amsco Steris Corporation 14
Atec A.R.M. Alphatec Spine, Inc. 13
Universal table top Maquet Gmbh 13
Magnus operating table system Maquet Gmbh 8

Showing 12 of 442. All products under Table, Operating-Room, Ac-Powered

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-07-14 Class II Under Investigation by firm Under certain conditions, such as the simultaneous use of the operating table with other medical devices, including high-frequency (HF) surgical equipment, interference may occur that could prevent the device from performing as intended. If 315 units (8 US, 307 OUS)
2008-09-26 Not classified Other During installation or cleaning there is a risk of crushing the finger by handling the head rest in the area of the gas strut while simultaneously actuating the release lever. 88 units in US; 1884 units worldwide 2009-04-16
2008-09-16 Not classified Equipment maintenance Table tilts: The Alphastar Surgical Table piston rod head may break and cause a full inclination of the table top during Trendelenberg positioning if there is insufficient lubrication. 141 in US 2010-01-12

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer