iLED7 Surgical Light

iLED 7 Mobile

Registry build 21.09.26
1manufacturer
1catalogue number

Who Else Makes It

Registered in Guangdong. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code FSS
Manufacturer City Province Registered as Device types
Shenzhen Kaiyan Medical Equipment Co., Ltd. Shenzhen Guangdong Contract manufacturer 17

Record

Regulatory record for iLED7 Surgical Light
Listed by Baxter Medical Systems GmbH + Co. KG, Germany
FDA product code FSS
Device type Light, Surgical, Floor Standing
Device class Class 2
Regulation 21 CFR 878.4580
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2023-01-05
Record revised 2025-06-27 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries manufacturing date, serial number
Distribution end date 2025-04-28

Catalogue Numbers

Catalogue numbers for iLED7 Surgical Light
Catalogue number Size Status
4068120 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Maquet Rolite Maquet Gmbh 35
StarTrol Huot Instruments, LLC 9
HarmonyAIR Steris Corporation 6
Aesculap Aesculap AG 5
Lucea LED® Maquet Gmbh 4
Amtai Amtai Medical Equipment, Inc. 4
Nico Myriad-LX Nico Corporation 3
Sunoptic Technologies Sunoptic Technologies, LLC 3
Aurora Surgical Light Series Skytron, LLC 2
Maxx Luxx LED 160 Avante 2
MS Sim.LED OpL wDB S.i.m.e.o.n. Medical GMBH & Co.KG 2
STARLED3 NX Acem SPA 2

Showing 12 of 37. All products under Light, Surgical, Floor Standing

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of iLED7 Surgical Light
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Baxter Healthcare Corporation UDI-DI 2024-06-04 Class II Under Investigation by firm Baxter Healthcare Corporation is issuing an Urgent Medical Device Correction due to customer reports of thermal skin injuries when using the iLED 7 surgical light
system products listed below. Specific VidiaPort and Trulight product codes a
6243 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker