Standop Volista®

VST60DF: Volista Sandop

Registry build 21.09.26
5manufacturers in China registered for this device type
50catalogue numbers in this listing
3recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Shandong (1), Jiangxi (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code FSY
Manufacturer City Province Registered as Device types
Shenzhen Kaiyan Medical Equipment Co., Ltd. Shenzhen Guangdong Contract manufacturer 17
Beijing Aeonmed Co., Ltd. Sanhe Hebei Contract manufacturer 7
Guangdong Kareway Medical Technology Co., Ltd. Foshan Guangdong Manufacturer 16
Shandong Deman Medical Equipment Group Co., Ltd. Jining Shandong Manufacturer 11
Nanchang Micare Medical Equipment Co., Ltd. Nanchang Jiangxi Manufacturer 8

Record

Regulatory record for Standop Volista®
Listed by Maquet Gmbh, Germany
FDA product code FSY
Device type Light, Surgical, Ceiling Mounted
Device class Class 2
Regulation 21 CFR 878.4580
Establishment Specification developer, Repacker / relabeller, Manufacturer
510(k) K130513
Record published 2017-01-31
Record revised 2024-12-16 (version 7)

Specifications

Specifications
MRI safety MR Unsafe
Label carries manufacturing date, serial number
Storage Handling environment atmospheric pressure 50 to 106 KiloPascal; Storage environment atmospheric pressure 50 to 106 KiloPascal; Handling environment humidity 20 to 75 % RH; Storage environment humidity 20 to 75 % RH; Handling environment temperature -10 to 60 °C; Storage environment temperature -10 to 60 °C
Distribution end date 2024-10-09

Catalogue Numbers

Catalogue numbers for Standop Volista®
Catalogue number Size Status
ARDSAT209021A Withdrawn
ARDSAT209018A Withdrawn
ARDVST229018A Withdrawn
ARDSAT209013A Withdrawn
ARDSAT209037A Withdrawn
ARDSAT209036A Withdrawn
ARDSAT209040A Withdrawn
ARDVST229010A Withdrawn
ARDVST229027A Withdrawn
ARDSAT209031A Withdrawn
ARDSAT209030A Withdrawn
ARDVST229019A Withdrawn
ARDVST229026A Withdrawn
ARDVST228002A Withdrawn
ARDVST229011A Withdrawn
ARDVST229004A Withdrawn
ARDVST229039A Withdrawn
ARDVST229002A Withdrawn
ARDSAT209019A Withdrawn
ARD2STP00200A Withdrawn
ARDSAT209024A Withdrawn
ARDSAT209016A Withdrawn
ARDVST229049A Withdrawn
ARDVST229014A Withdrawn
ARDVST229023A Withdrawn
ARDSAT209027A Withdrawn
ARDSAT209025A Withdrawn
ARDVST229013A Withdrawn
ARDVST229030A Withdrawn
ARDSAT209012A Withdrawn
ARDVST229008A Withdrawn
ARDVST229005A Withdrawn
ARDSAT209032A Withdrawn
ARDVST229032A Withdrawn
ARDVST228000A Withdrawn
ARDVST229007A Withdrawn
ARDSAT209029A Withdrawn
ARDVST229009A Withdrawn
ARDSAT209028A Withdrawn
ARDSAT209023A Withdrawn
ARDVST229006A Withdrawn
ARDSAT209020A Withdrawn
ARDVST229003A Withdrawn
ARDVST229000A Withdrawn
ARDSAT209039A Withdrawn
ARDVST229022A Withdrawn
ARDVST229001A Withdrawn
ARDVST229036A Withdrawn
ARDSAT209017A Withdrawn
ARDSAT209033A Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
HarmonyAIR Steris Corporation 1,344
Volista Maquet Gmbh 677
iCE Surgical Light Amico Clinical Solutions 599
Powerled TM Maquet Gmbh 287
Devon Cardinal Health 70
Light, Surgical, Ceiling Mounted Maquet Gmbh 68
Alyon Steris Corporation 64
Medical Boom Amico Clinical Solutions 56
Amtai Amtai Medical Equipment, Inc. 45
Mira Minor Surgery Light Amico Lights Corporation 24
MI Product Line Medical Illumination International, Inc 20
Kenex Kenex (Electro-Medical) Ltd. 18

Showing 12 of 191. All products under Light, Surgical, Ceiling Mounted

Recalls Naming This Product

19 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Standop Volista®
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Getinge Usa Sales Inc 510(k) number 2023-11-08 Class II Equipment maintenance A potential for a light system to fall in the operating room. 236793 units in total
Getinge Usa Sales Inc 510(k) number 2022-05-06 Class II Process change control Paint particles may detach and fall in the operating field. In the worst case scenario, infection, organ irritation, hypersensitivity reaction, and tissue granuloma may result if paint particles fall during surgical operation into the patie 337 (US); 8594 (OUS)
Maquet Cardiovascular Us Sales, Llc 510(k) number 2019-05-28 Class II Device Design Potential that the coating of the light head forks on the VOLISTA Surgical Lights may crack, posing the risk
of particles falling into the surgical field during surgery that may result in patient infection
2 units 2023-07-10
Maquet Cardiovascular Us Sales, Llc 510(k) number 2019-05-28 Class II Device Design Potential that the coating of the light head forks on the VOLISTA Surgical Lights may crack, posing the risk
of particles falling into the surgical field during surgery that may result in patient infection
11 units 2023-07-10
Maquet Cardiovascular Us Sales, Llc 510(k) number 2019-05-28 Class II Device Design Potential that the coating of the light head forks on the VOLISTA Surgical Lights may crack, posing the risk
of particles falling into the surgical field during surgery that may result in patient infection
65 units 2023-07-10
Maquet Cardiovascular Us Sales, Llc 510(k) number 2019-05-28 Class II Device Design Potential that the coating of the light head forks on the VOLISTA Surgical Lights may crack, posing the risk
of particles falling into the surgical field during surgery that may result in patient infection
46 units 2023-07-10
Maquet Cardiovascular Us Sales, Llc 510(k) number 2019-05-28 Class II Device Design Potential that the coating of the light head forks on the VOLISTA Surgical Lights may crack, posing the risk
of particles falling into the surgical field during surgery that may result in patient infection
7 units 2023-07-10
Maquet Cardiovascular Us Sales, Llc 510(k) number 2019-05-28 Class II Device Design Potential that the coating of the light head forks on the VOLISTA Surgical Lights may crack, posing the risk
of particles falling into the surgical field during surgery that may result in patient infection
2 units 2023-07-10
Maquet Cardiovascular Us Sales, Llc 510(k) number 2019-05-28 Class II Device Design Potential that the coating of the light head forks on the VOLISTA Surgical Lights may crack, posing the risk
of particles falling into the surgical field during surgery that may result in patient infection
6 units 2023-07-10
Maquet Cardiovascular Us Sales, Llc 510(k) number 2019-05-28 Class II Device Design Potential that the coating of the light head forks on the VOLISTA Surgical Lights may crack, posing the risk
of particles falling into the surgical field during surgery that may result in patient infection
12 units 2023-07-10
Maquet Cardiovascular Us Sales, Llc 510(k) number 2019-05-28 Class II Device Design Potential that the coating of the light head forks on the VOLISTA Surgical Lights may crack, posing the risk
of particles falling into the surgical field during surgery that may result in patient infection
11 units 2023-07-10
Maquet Cardiovascular Us Sales, Llc 510(k) number 2019-05-28 Class II Device Design Potential that the coating of the light head forks on the VOLISTA Surgical Lights may crack, posing the risk
of particles falling into the surgical field during surgery that may result in patient infection
5 units 2023-07-10
Maquet Cardiovascular Us Sales, Llc 510(k) number 2019-05-28 Class II Device Design Potential that the coating of the light head forks on the VOLISTA Surgical Lights may crack, posing the risk
of particles falling into the surgical field during surgery that may result in patient infection
2 units 2023-07-10
Maquet Cardiovascular Us Sales, Llc 510(k) number 2019-05-28 Class II Device Design Potential that the coating of the light head forks on the VOLISTA Surgical Lights may crack, posing the risk
of particles falling into the surgical field during surgery that may result in patient infection
9 units 2023-07-10
Maquet Cardiovascular Us Sales, Llc 510(k) number 2019-05-28 Class II Device Design Potential that the coating of the light head forks on the VOLISTA Surgical Lights may crack, posing the risk
of particles falling into the surgical field during surgery that may result in patient infection
10 units 2023-07-10
Maquet S.A.S. 510(k) number 2018-06-14 Class II Process control Certain VOLISTA StandOP Surgical Lights have been identified as having a potential light head detachment issue. Improper assembly of the bracket that connects the light head to the axle fork could result in the light head bracket breaking, 151 2022-06-23
Maquet S.A.S. 510(k) number 2018-04-19 Class II Device Design Potential keypad failure on VOLISTA StandOP Surgical Lights. 187 2020-11-18
Getinge US Sales LLC 510(k) number 2018-02-07 Class II Component design/selection The manufacturer received complaints indicating that the device’s central handle holder detaches easily from the handle holder ring on the light head during clinical use. In the event of such detachment, particles from the handle holder rin 5214 2021-09-02
Maquet Cardiovascular Us Sales, Llc 510(k) number 2015-05-29 Class II Device Design Maquet Suspension Arms used with PowerLED/X-TEN/Volista Surgical Light Systems may grind at the junction of the suspension arms which can cause paint chips or particles to fall into the surgical field, when the suspension arms are mounted a 646 units 2017-04-07

Recalls

The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2009-10-07 Not classified Device Design Several reports have been received regarding one model of spring arm (Acrobat 200 series) in combination with surgical light from various Manufacturers. All incidents pertain to a crack on the front joint of the Acrobat arm. 54 2012-06-04
2009-10-07 Not classified Device Design Several reports have been received regarding one model of spring arm (Acrobat 200 series) in combination with surgical light from various Manufacturers. All incidents pertain to a crack on the front joint of the Acrobat arm. 346 2012-06-04
2009-10-07 Not classified Device Design Several reports have been received regarding one model of spring arm (Acrobat 200 series) in combination with surgical light from various Manufacturers. All incidents pertain to a crack on the front joint of the Acrobat arm. 331 2012-06-04

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer