Light, Surgical, Accessories
The STERIS Sterile Camera Handle Covers are designed for HarmonyAIR surgical lights, and provide sterile Control that allow for increasing and decreasing illumination through seven…
The STERIS Sterile Camera Handle Covers are designed for HarmonyAIR surgical lights, and provide sterile Control that allow for increasing and decreasing illumination through seven intensity Levels. They are compatible with all Harmony and HarmonyAIR in-light cameras.
Who Else Makes It
Concentrated in Jiangsu (7), Zhejiang (6), Guangdong (4). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Suzhou Meccan Import and Export Corp. | Suzhou | Jiangsu | Contract manufacturer | 71 |
| Zhejiang Gongdong Medical Technology Co., Ltd. | Taizhou | Zhejiang | Contract manufacturer | 40 |
| Vincent Medical (Dong Guan) Manufacturing Co., Ltd. | Dong Guan | Guangdong | Contract manufacturer | 29 |
| Suzhou Jinsheng Plastic Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Henso Medical (Hangzhou) Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 19 |
| Suzhou Jingle Polymer Medical Apparatus Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Rongxing Plastic Jurong Co., Ltd. | Zhenjiang | Jiangsu | Contract manufacturer | 8 |
| Shanghai Everpure Plastics Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 7 |
| Boen Healthcare Co., Ltd. | Suzhou | Jiangsu | Specification developer | 263 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| GRI Medical & Electronic Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 71 |
| Gcmedica Enterprise Ltd.(Wuxi) | Wuxi | Jiangsu | Contract manufacturer | 55 |
Showing 12 of 21. All 21 manufacturers in China registered for Light, Surgical, Accessories
Record
| Listed by | Steris Corporation, United States |
|---|---|
| FDA product code | FTA |
| Device type | Light, Surgical, Accessories |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4580 |
| Establishment | Contract manufacturer, Contract steriliser, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2020-05-14 |
| Record revised | 2022-11-09 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Over the counter | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Keep dry and keep from sunlight |
| Packaging | Case of 100, case of 30, case of 4, box of 30 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| LB82 | 2 | In distribution | |
| LB83 | In distribution | ||
| LB85 | In distribution | ||
| Sterile Camera Handle Cover | In distribution | ||
| Sterile Lighthandle Cover | In distribution | ||
| LB84 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Aspen® Flexible Light Handle Adapter | Aspen Surgical Products, Inc. | 290 |
| Litex | Litex Manufacturing, Inc. | 226 |
| DeRoyal | Deroyal Industries, Inc. | 215 |
| Aspen® Rigid Light Handle Adapter | Aspen Surgical Products, Inc. | 212 |
| Light, Surgical, Accessories | Maquet Gmbh | 72 |
| Medical Action Industries | Medical Action Industries, Inc. | 42 |
| Olympus | Gyrus Acmi, Inc. | 37 |
| Aspen® Flexible Light Handle Cover | Aspen Surgical Products, Inc. | 14 |
| Helion | Videomed SRL | 14 |
| Cardinal Health | Cardinal Health 200, LLC | 13 |
| Alleset | GRI Medical & Electronic Technology Co., Ltd. | 8 |
| Aspen® Rigid Light Handle Cover | Aspen Surgical Products, Inc. | 6 |
Showing 12 of 74. All products under Light, Surgical, Accessories
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Steris Corporation | UDI-DI | 2023-03-17 | Class II | Under Investigation by firm | Light handle covers may separate from the light handle (detach and fall off) during use, this could result in a procedure delay and/or impact the sterile field which could result in an injury to the patient | 1,358,520 covers |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2023-03-17 | Class II | Under Investigation by firm | Light handle covers may separate from the light handle (detach and fall off) during use, this could result in a procedure delay and/or impact the sterile field which could result in an injury to the patient | 263,280 covers |