Lucea LED®
LCA50 Upgrade Wall Mounted
Who Else Makes It
Concentrated in Guangdong (2), Shanghai (2), Jiangsu (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shanghai Huifeng Medical Instrument Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 4 |
| Dragon Medical Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 48 |
| Shenzhen Comen Medical Instruments Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 24 |
| HI-Life Technology (Hebei) Co., Ltd. | Bazhou | Hebei | Manufacturer | 11 |
| Shenzhen Youmay Electronics Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 10 |
| Shanghai PAX Medical Instrument Co., Ltd. | Shanghai | Shanghai | Manufacturer | 7 |
Record
| Listed by | Maquet Gmbh, Germany |
|---|---|
| FDA product code | FTD |
| Device type | Lamp, Surgical |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4580 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| 510(k) | K113679 |
| Record published | 2016-09-15 |
| Record revised | 2024-11-18 (version 7) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Label carries | manufacturing date, serial number |
| Storage | Storage environment humidity 20 to 75 % RH; Handling environment temperature -10 to 60 °C; Handling environment humidity 20 to 75 % RH; Storage environment temperature -10 to 60 °C; Handling environment atmospheric pressure 50 to 106 KiloPascal; Storage environment atmospheric pressure 50 to 106 KiloPascal |
| Distribution end date | 2024-10-14 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| ARDLCA109007A | Withdrawn | |
| ARDLCA506007A | Withdrawn | |
| ARDLCA109005A | Withdrawn | |
| ARDLCA506004A | Withdrawn | |
| ARDLCA109004A | Withdrawn | |
| ARDLCA506005A | Withdrawn | |
| ARDLCA506003A | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Maquet PowerLED II | Maquet Gmbh | 1,930 |
| S300 Series | Dentis Co., Ltd. | 41 |
| Standop Volista® | Maquet Gmbh | 32 |
| L400 Series | Dentis Co., Ltd. | 24 |
| M400 Series (Ceiling, Mobile) | Dentis Co., Ltd. | 24 |
| Lamp, Surgical | Maquet Gmbh | 18 |
| Maquet Ezea | Maquet Gmbh | 18 |
| Maisilide | Shandong Deman Medical Equipment Group Co., Ltd. | 15 |
| S250 Series(Ceiling, Mobile) | Dentis Co., Ltd. | 11 |
| StarTrol | Huot Instruments, LLC | 7 |
| Rolite Volista Standop | Maquet Gmbh | 5 |
| Lewin | Shandong Lewin Medical Equipment Co., Ltd. | 5 |
Showing 12 of 52. All products under Lamp, Surgical
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Getinge Usa Sales Inc | 510(k) number | 2023-11-08 | Class II | Equipment maintenance | A potential for a light system to fall in the operating room. | 236793 units in total |
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2009-10-07 | Not classified | Device Design | Several reports have been received regarding one model of spring arm (Acrobat 200 series) in combination with surgical light from various Manufacturers. All incidents pertain to a crack on the front joint of the Acrobat arm. | 39 | 2012-06-04 |
| 2009-10-07 | Not classified | Device Design | Several reports have been received regarding one model of spring arm (Acrobat 200 series) in combination with surgical light from various Manufacturers. All incidents pertain to a crack on the front joint of the Acrobat arm. | 3 | 2012-06-04 |
| 2009-10-07 | Not classified | Device Design | Several reports have been received regarding one model of spring arm (Acrobat 200 series) in combination with surgical light from various Manufacturers. All incidents pertain to a crack on the front joint of the Acrobat arm. | 1 | 2012-06-04 |
| 2009-10-07 | Not classified | Device Design | Several reports have been received regarding one model of spring arm (Acrobat 200 series) in combination with surgical light from various Manufacturers. All incidents pertain to a crack on the front joint of the Acrobat arm. | 166 | 2012-06-04 |
| 2009-02-23 | Not classified | Device Design | The screws holding the Prismatic triple surgical lights may break due to dynamic multidirectional bending stress. The firm has received one complaint report. | 54 of all units, both article numbers | 2009-09-29 |
| 2009-02-23 | Not classified | Device Design | The screws holding the Prismatic triple surgical lights may break due to dynamic multidirectional bending stress. The firm has received one complaint report. | 54 of all units, both article numbers | 2009-09-29 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.