Salvin Dental Specialties
Individual 1001 Salvin Sterile Gown/Towel Pack
Who Else Makes It
Concentrated in Jiangsu (16), Hubei (13), Anhui (10). 28 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GRI Medical & Electronic Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 71 |
| Suzhou Meccan Import and Export Corp. | Suzhou | Jiangsu | Contract manufacturer | 71 |
| Principle & Will Biotech (Pinghu) Co., Ltd. | Pinghu | Zhejiang | Contract manufacturer | 39 |
| Henan Yadu Industrial Co., Ltd. | Changyuan | Henan | Contract manufacturer | 35 |
| Jiangsu JianYu Health Medical Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 35 |
| Sino Protection (Hefei) Medical Products Co., Ltd. | Hefei | Anhui | Contract manufacturer | 18 |
| Exact Medical Manufacturing, Inc. | Changzhou | Jiangsu | Contract manufacturer | 17 |
| Kingstar Medical (Xianning) Co., Ltd. | Xianning | Hubei | Contract manufacturer | 17 |
| Changzhou Holymed Products Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 16 |
| Weihai Dishang Medical Technology Co., Ltd. | Weihai | Shandong | Contract manufacturer | 16 |
| Lianyungang Bronson Non-woven Products Co., Ltd. | Lianyungang | Jiangsu | Contract manufacturer | 16 |
| Heyuan Hong DE Medical Products Co., Ltd. | Heyuan | Guangdong | Contract manufacturer | 13 |
Showing 12 of 68. All 68 manufacturers in China registered for Gown, Surgical
Record
| Listed by | Salvin Dental Specialties, LLC, United States |
|---|---|
| FDA product code | FYA |
| Device type | Gown, Surgical |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4040 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer, Exporter |
| 510(k) | K964142 |
| Record published | 2025-11-11 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Packaging | Inner pack of 10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1001 | In distribution | |
| 1034 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Medline | Medline Industries, Inc. | 453 |
| Halyard | O&M Halyard, Inc. | 248 |
| Novo Health Services, LLC | Novo Health Services, LLC | 222 |
| Alleset | GRI Medical & Electronic Technology Co., Ltd. | 214 |
| Convertors | Cardinal Health 200, LLC | 184 |
| Lac-Mac | LAC-MAC Limited | 157 |
| Invenio | GRI Medical & Electronic Technology Co., Ltd. | 126 |
| Exact Medical Manufacturing, Inc. | Exact Medical Manufacturing, Inc. | 107 |
| ComPel Surgical Gown | Standard Textile Co., Inc. | 67 |
| Halyard | GRI Medical & Electronic Technology Co., Ltd. | 55 |
| ComPel MLR Surgical Gown | Standard Textile Co., Inc. | 38 |
| Medline Industries, Inc. | Medline Industries, Inc. | 35 |
Showing 12 of 172. All products under Gown, Surgical
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Principle & Will Biotech (Pinghu) Co., Ltd. | 510(k) number | 2017-06-01 | Class II | Other | The sleeve seam of the breathable material was found to have inconsistent sealing, which has the potential to allow fluid to flow pass through the protective seam. | 2,160 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.