Aesculap
CHALLENGER TI-P Clip Applier Forceps, pneumatic, multi-fire, (260 mm), diam. 10 mm, consisting of PL520R, PL538R, reusable, reposable, to be used with: PL575SU, PL579T
Who Else Makes It
Concentrated in Shanghai (1), Beijing (1), Zhejiang (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Hangzhou Kangji Medical Instrument Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 27 |
| Jiangsu Bana Medical Technology Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 4 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Beijing Zksk Technology Co., Ltd. | Beijing | Beijing | Contract manufacturer | 38 |
Record
| Listed by | Aesculap AG, Germany |
|---|---|
| FDA product code | FZP |
| Device type | Clip, Implantable |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4300 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2016-09-23 |
| Record revised | 2022-11-28 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 0 to 50 °C |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| PL575SU | 3 | In distribution | |
| PL475SU | Material : titanium | 12 | In distribution |
| PL468SU | Material : titanium | 12 | In distribution |
| PL608R | Working length (mm) : 260.000 MM | In distribution | |
| PL574T | Material : titanium | 12 | In distribution |
| PL579T | Material : titanium | 12 | In distribution |
| PL603R | Working length (mm) : 205.000 MM | In distribution | |
| PL471SU | Material : titanium | 12 | In distribution |
| PL462SU | Material : titanium | 15 | In distribution |
| PL452SU | Material : titanium | 6 | In distribution |
| PL465SU | Material : titanium | 15 | In distribution |
| PL459SU | Material : titanium | 15 | In distribution |
| PL569T | Material : titanium | 12 | In distribution |
| PL453SU | Material : titanium | 15 | In distribution |
| PL606R | Working length (mm) : 370.000 MM | In distribution | |
| PL506R | Diameter (mm) : 10.000 MM | In distribution | |
| PL450SU | Material : titanium | 15 | In distribution |
| PL572T | Material : titanium | 12 | In distribution |
| PL520R | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Weck | Teleflex Medical LLC | 321 |
| Teleflex | Teleflex Medical LLC | 57 |
| AtriClip™ LAA Exclusion System | Atricure, Inc. | 40 |
| Medline | Medline Industries, Inc. | 15 |
| AtriClip Flex•v | Atricure, Inc. | 12 |
| E-Pack | Ethicon, Inc. | 12 |
| AtriClip® Pro•v™ LAA Exclusion System | Atricure, Inc. | 12 |
| Titanium Ligation Clip | Vesocclude Medical, LLC | 11 |
| SLS-Clip | Vitalitec Surgical | 10 |
| SLS-Clip Vitalitec | Peters Surgical | 10 |
| MirusTM Ligating Clip | Meril Endo Surgery PVT. Ltd. | 10 |
| Clip 9 Vitalitec | Peters Surgical | 10 |
Showing 12 of 70. All products under Clip, Implantable
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K202124 | 2020-09-02 |
| K102081 | 2010-08-06 |
| K081031 | 2008-05-05 |
| K080753 | 2008-04-02 |
Recalls
4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2021-04-16 | Class II | Under Investigation by firm | Malfuncton-Implant did not deploy successfully may necessitate the need for an additional medical intervention for patients which would result in a potential delay in surgery | 350 units | 2023-01-18 |
| 2021-04-16 | Class II | Under Investigation by firm | Malfuncton-Implant did not deploy successfully may necessitate the need for an additional medical intervention for patients which would result in a potential delay in surgery | 80 units | 2023-01-18 |
| 2018-01-22 | Class II | Labeling design | Added a contraindication to IFU: Do not use the DS clips for living donor nephrectomies. Added other contraindications. A publication from 2017 recommended Aesculap DS Clips for kidney transplantation with living donors. The information f | 9621 | 2019-09-24 |
| 2018-01-22 | Class II | Labeling design | Added a contraindication to IFU: Do not use the DS clips for living donor nephrectomies. Added other contraindications. Updated cleaning and sterilization instructions. | 270 | 2019-09-24 |