Click’X
Holding Sleeve FOR Click'x® Preassembled Screws
Who Else Makes It
Concentrated in Jiangsu (10), Zhejiang (5), Guangdong (4). 14 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Well Lead Medical Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 46 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Xinhua Healthcare Industry Co., Limited | Zibo | Shandong | Contract manufacturer | 30 |
| Guangzhou Aquila Precise Tools Limited | Guangzhou | Guangdong | Contract manufacturer | 28 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Turnxon Precision Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 17 |
| Beilun Plastech Inc | Ningbo | Zhejiang | Contract manufacturer | 13 |
Showing 12 of 26. All 26 manufacturers in China registered for Guide, Surgical, Instrument
Record
| Listed by | Synthes Gmbh, Switzerland |
|---|---|
| FDA product code | FZX |
| Device type | Guide, Surgical, Instrument |
| Device class | Class 1 |
| Regulation | 21 CFR 878.4800 |
| Establishment | Specification developer, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2016-12-31 |
| Record revised | 2022-04-27 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 388.367 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| DJO Surgical | Encore Medical, L.P. | 2,141 |
| Guide, Surgical, Instrument | Synthes Gmbh | 727 |
| DJO Surgical | DJO, LLC | 284 |
| Apex Knee System | Omni Life Science, Inc. | 272 |
| Medtronic Reusable Instruments | Medtronic Sofamor Danek, Inc. | 223 |
| Motoband CP | Crossroads Extremity Systems LLC | 221 |
| Advance® | Microport Orthopedics Inc. | 199 |
| NexGen® | Zimmer, Inc. | 194 |
| Evolution® | Microport Orthopedics Inc. | 173 |
| Innomed, Inc. | Innomed, Inc. | 172 |
| Newclip Instruments | Newclip Technics SAS | 144 |
| Guide, Surgical, Instrument | Zimmer, Inc. | 135 |
Showing 12 of 1,788. All products under Guide, Surgical, Instrument
Recalls
4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2017-08-07 | Class II | Process design | May have difficulty attaching the drill sleeve to the plate. If the drill sleeve will not connect to the plate intraoperatively, surgical delay could occur. If the pilot hole is drilled without the drill sleeve, the pilot hole could be off- | 567 units | 2018-07-25 |
| 2015-05-28 | Class II | Component design/selection | Certain affected parts and lots of the Pull Reduction Devices may have been manufactured to an incorrect hardness specification which could result in intraoperative breakage. | 3747 US, 19 Foreign | 2016-08-22 |
| 2015-02-17 | Class II | Process control | For certain lots, the incorrect raw material of annealed 17-4PH Stainless Steel was used instead of the correct material of heat-treated 304 Stainless Steel. This may lead to stress-corrosion cracking, which can lead to surgical delay or u | 183 | 2016-08-26 |
| 2014-01-27 | Class II | Process control | One lot of Matrix Mandible Short Threaded Drill Guides (part No. 03.503.043) has a gray colored band instead of a green colored band as pictured in the Technique Guide. | 12 | 2015-07-20 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.