Integra®
Integra® Silicone-Coated Brain Retractor Self-Retaining Model
Who Else Makes It
Concentrated in Jiangsu (10), Shanghai (7), Zhejiang (6). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| B.Braun Medical (Suzhou) Co,.Ltd | Suzhou | Jiangsu | Contract manufacturer | 37 |
| Suzhou Microport Orthorecon Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 31 |
| Xinhua Healthcare Industry Co., Limited | Zibo | Shandong | Contract manufacturer | 30 |
| B-ONE Medical (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Shanghai KiNETIC Medical Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Shanghai Medical Instruments (Group) Ltd. Corp. | Shanghai | Shanghai | Contract manufacturer | 235 |
| Xinhua Surgical Instrument Co., Ltd. | Zibo | Shandong | Manufacturer | 222 |
| MicroPort Orthopedics Global Supply Center Limited | Shanghai | Shanghai | Contract manufacturer | 82 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
Showing 12 of 34. All 34 manufacturers in China registered for Retractor
Record
| Listed by | Integra Lifesciences Corporation, United States |
|---|---|
| FDA product code | GAD |
| Device type | Retractor |
| Device class | Class 1 |
| Regulation | 21 CFR 878.4800 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2016-06-20 |
| Record revised | 2023-04-18 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| NL7702703 | Width: 15.9mm, Blade Length: 76mm, Total Length: 127mm | In distribution |
| NL8700214 | 22mm width x 20cm length | In distribution |
| NL8700200 | One set of each of 5 sizes: 6mm width x 20cm length; 9.5 mm width x 20cm length; 13mm width x 20cm length; 16mm width x 20cm length; 22mm width x 20cm length | In distribution |
| NL7702702 | Width: 12.7mm, Blade Length: 76mm, Total Length: 127mm | In distribution |
| NL8700210 | 16mm width x 20cm length | In distribution |
| NL8700208 | 13mm width x 20cm length | In distribution |
| NL8700204 | 6mm width x 20cm length | In distribution |
| NL8700206 | 9.5 mm width x 20cm length | In distribution |
| NL7702707 | Width: 20mm, Blade Length: 95mm, Total Length: 146mm | In distribution |
| NL7702708 | Width: 25mm, Blade Length: 75mm, Total Length: 127mm | In distribution |
| NL7702701 | Width: 9.5mm, Blade Length: 76mm, Total Length: 127mm | In distribution |
| NL7702705 | Width: 15mm, Blade Length: 70mm, Total Length: 122mm | In distribution |
| NL7702704 | Width: 22.2mm, Blade Length: 76mm, Total Length: 127mm | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Thompson | Thompson Surgical Instruments, Inc. | 4,354 |
| Millennium | Avalign Technologies, Inc. | 2,128 |
| Surtex | Surtex Instruments Ltd | 1,318 |
| Life Instruments | Life Instrument Corp. | 1,135 |
| Innomed, Inc. | Innomed, Inc. | 1,017 |
| Aesculap | Aesculap AG | 1,013 |
| RZ Medizintechnik GmbH | RZ Medizintechnik Gmbh | 973 |
| Elmed | Elmed, Inc. | 919 |
| Medtronic Reusable Instruments | Medtronic Sofamor Danek, Inc. | 891 |
| Boss Instruments | Boss Instruments, Ltd. | 799 |
| gSource | Gsource, LLC. | 753 |
| Sklar® | Sklar Corporation | 753 |
Showing 12 of 2,238. All products under Retractor
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2026-06-05 | Class II | Labeling design | The current Omni-Tract Surgical Retractor System IFU states a dry time of 30 minutes. Integra LifeSciences has identified that the dry time needs to be extended to 90 minutes, 110 minutes, or 120 minutes depending on the sterilization cycle | 633 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.