KG-2 Koplight Light Handle (Infrared Cut-off Model)

Catalogue number KG-2, listed by Yasui Co., Ltd., Japan, under Retractor. 34 manufacturers in China are registered for this product code.

Registry build 21.09.26
34manufacturers in China registered for this device type
1catalogue number

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (7), Zhejiang (6). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code GAD
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
B.Braun Medical (Suzhou) Co,.Ltd Suzhou Jiangsu Contract manufacturer 37
Suzhou Microport Orthorecon Co., Ltd. Suzhou Jiangsu Contract manufacturer 31
Xinhua Healthcare Industry Co., Limited Zibo Shandong Contract manufacturer 30
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Shanghai KiNETIC Medical Co Ltd Shanghai Shanghai Contract manufacturer 19
Shanghai Medical Instruments (Group) Ltd. Corp. Shanghai Shanghai Contract manufacturer 235
Xinhua Surgical Instrument Co., Ltd. Zibo Shandong Manufacturer 222
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74

Showing 12 of 34. All 34 manufacturers in China registered for Retractor

Record

Regulatory record for KG-2 koplight light handle (Infrared cut-off model)
Listed by Yasui Co., Ltd., Japan
FDA product code GAD
Device type Retractor
Device class Class 1
Regulation 21 CFR 878.4800
Establishment Contract manufacturer, Manufacturer
Premarket notification Exempt
Record published 2024-08-19
Record revised 2025-09-05 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Hydrogen Peroxide, Ethylene Oxide
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, manufacturing date
Storage Storage environment temperature 0 to 40 °C; Handling environment temperature 0 to 40 °C; Storage environment humidity 30 to 90 % RH; Handling environment humidity 30 to 90 % RH; Storage environment atmospheric pressure 70 to 106 KiloPascal; Handling environment atmospheric pressure 70 to 106 KiloPascal
Sizes Outer diameter 15 mm; length 155 mm

Catalogue Numbers

Catalogue numbers for KG-2 koplight light handle (Infrared cut-off model)
Catalogue number Size Status
KG-2 Outer Diameter 15.0 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Thompson Thompson Surgical Instruments, Inc. 4,354
Millennium Avalign Technologies, Inc. 2,128
Surtex Surtex Instruments Ltd 1,318
Life Instruments Life Instrument Corp. 1,135
Innomed, Inc. Innomed, Inc. 1,017
Aesculap Aesculap AG 1,013
RZ Medizintechnik GmbH RZ Medizintechnik Gmbh 973
Elmed Elmed, Inc. 919
Medtronic Reusable Instruments Medtronic Sofamor Danek, Inc. 891
Boss Instruments Boss Instruments, Ltd. 799
gSource Gsource, LLC. 753
Sklar® Sklar Corporation 753

Showing 12 of 2,238. All products under Retractor

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer