Valve XS

VALVE XS Atrium Retractor, complete set, consisting of FC361R, FC362R, FC363R, FC364R, FC365R, FC366R, FC367R, non-sterile, reusable

Registry build 21.09.26
34manufacturers in China registered for this device type
27catalogue numbers in this listing
2recalls on this code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (7), Zhejiang (6). 8 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code GAD
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
B.Braun Medical (Suzhou) Co,.Ltd Suzhou Jiangsu Contract manufacturer 37
Suzhou Microport Orthorecon Co., Ltd. Suzhou Jiangsu Contract manufacturer 31
Xinhua Healthcare Industry Co., Limited Zibo Shandong Contract manufacturer 30
B-ONE Medical (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 23
Shanghai KiNETIC Medical Co Ltd Shanghai Shanghai Contract manufacturer 19
Shanghai Medical Instruments (Group) Ltd. Corp. Shanghai Shanghai Contract manufacturer 235
Xinhua Surgical Instrument Co., Ltd. Zibo Shandong Manufacturer 222
MicroPort Orthopedics Global Supply Center Limited Shanghai Shanghai Contract manufacturer 82
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74

Showing 12 of 34. All 34 manufacturers in China registered for Retractor

Record

Regulatory record for Valve XS
Listed by Aesculap AG, Germany
FDA product code GAD
Device type Retractor
Device class Class 1
Regulation 21 CFR 878.4800
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2020-04-24
Record revised 2023-08-25 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Distribution end date 2021-08-02
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Valve XS
Catalogue number Size Status
FC428R In distribution
FC142R In distribution
FC140R In distribution
FC421R In distribution
FC431R In distribution
FC362R In distribution
FC364R In distribution
FC141R In distribution
FC366R In distribution
FC425R In distribution
FC430R In distribution
FC361R In distribution
FC433R In distribution
FC432R In distribution
FC435R In distribution
FC145R In distribution
FC143R In distribution
FC365R In distribution
FC367R In distribution
FC429R In distribution
FC426R In distribution
FC434R In distribution
FC427R In distribution
FC420R In distribution
FC424R In distribution
FC363R In distribution
FC360R Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Thompson Thompson Surgical Instruments, Inc. 4,354
Millennium Avalign Technologies, Inc. 2,128
Surtex Surtex Instruments Ltd 1,318
Life Instruments Life Instrument Corp. 1,135
Innomed, Inc. Innomed, Inc. 1,017
Aesculap Aesculap AG 1,013
RZ Medizintechnik GmbH RZ Medizintechnik Gmbh 973
Elmed Elmed, Inc. 919
Medtronic Reusable Instruments Medtronic Sofamor Danek, Inc. 891
Boss Instruments Boss Instruments, Ltd. 799
gSource Gsource, LLC. 753
Sklar® Sklar Corporation 753

Showing 12 of 2,238. All products under Retractor

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2015-11-17 Class II Mixed-up of materials/components AAG received a customer complaint that corrosion had been found by a hospitals central sterile service department on the ball joint of an FC424R blade. Investigation revealed that the corrosion was due to incorrect material used in the manu 41 2016-10-13
2013-07-16 Class II Process change control Changes were implemented to the UNITRAC instructions for use to ensure safe use and potentially extend the life of the product. This included recommending the use of Sterile Cover JG901 and new Quick Release Coupling RT02OR to eliminate the 217 2014-08-26

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer