Coated Vicryl
Coated Vicryl (Polyglactin 910) Suture, Violet Braided, Sterile, Synthetic Absorbable Suture
Who Else Makes It
Concentrated in Shanghai (1), Shandong (1), Beijing (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Foosin Medical Supplies Inc.ltd | Weihai | Shandong | Manufacturer | 8 |
| ARC Medical Supplies (Beijing) Co., Ltd. | Beijing | Beijing | Manufacturer | 7 |
| Sichuan Innovation Technology Co., Ltd. | Chengdu | Sichuan | Contract manufacturer | 2 |
Record
| Listed by | Johnson & Johnson Medical GmbH, Germany |
|---|---|
| FDA product code | GAM |
| Device type | Suture, Absorbable, Synthetic, Polyglycolic Acid |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4493 |
| Establishment | Contract manufacturer, Manufacturer |
| Record published | 2015-09-01 |
| Record revised | 2026-05-27 (version 12) |
Specifications
| MRI safety | MR Safe |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Packaging | Box of 36, box of 12 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| J486H | In distribution | |
| J335H | In distribution | |
| J364H | In distribution | |
| J365H | In distribution | |
| J977H | In distribution | |
| J474H | In distribution | |
| J587H | In distribution | |
| J945H | In distribution | |
| J316H | In distribution | |
| J418H | In distribution | |
| J870H | In distribution | |
| J341H | In distribution | |
| J359H | In distribution | |
| J944H | In distribution | |
| J519H | In distribution | |
| J917H | In distribution | |
| J467H | In distribution | |
| J306H | In distribution | |
| J321H | In distribution | |
| J958H | In distribution | |
| J347H | In distribution | |
| J345H | In distribution | |
| J232H | In distribution | |
| J317H | In distribution | |
| J497H | In distribution | |
| J329H | In distribution | |
| J352H | In distribution | |
| J946H | In distribution | |
| J9441G | In distribution | |
| J461H | In distribution | |
| J344H | In distribution | |
| JV1069H | In distribution | |
| J1036H | In distribution | |
| J333H | In distribution | |
| J978H | In distribution | |
| J322H | In distribution | |
| J586H | In distribution | |
| J473H | In distribution | |
| J468H | In distribution | |
| J479H | In distribution | |
| J485H | In distribution | |
| J260H | In distribution | |
| J269H | In distribution | |
| J517H | In distribution | |
| J340H | In distribution | |
| J323H | In distribution | |
| J363H | In distribution | |
| J330H | In distribution | |
| J496H | In distribution | |
| J338H | In distribution | |
| J518H | In distribution | |
| J370H | In distribution | |
| J459H | In distribution | |
| J371H | In distribution | |
| J216H | In distribution | |
| J497G | In distribution | |
| J959H | In distribution | |
| J261H | In distribution | |
| J346H | In distribution | |
| J417H | In distribution | |
| J453H | In distribution | |
| J267H | In distribution | |
| J339H | In distribution | |
| J460H | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Novosyn | B Braun Surgical SA | 2,286 |
| DemeCRYL | Demetech Corp. | 2,092 |
| DemeSORB | Demetech Corp. | 1,625 |
| Safil | B Braun Surgical SA | 1,613 |
| Monosyn | B Braun Surgical SA | 1,096 |
| E-Pack | Ethicon, Inc. | 967 |
| Coated Vicryl | Ethicon, Inc. | 933 |
| DemeQUICK | Demetech Corp. | 732 |
| Polysorb | Covidien LP | 732 |
| DemeCAPRONE | Demetech Corp. | 707 |
| Wego-PGA Absorbable Surgical Suture With Needle | Foosin Medical Supplies Inc.ltd | 554 |
| Safil Quick+ | B Braun Surgical SA | 414 |
Showing 12 of 463. All products under Suture, Absorbable, Synthetic, Polyglycolic Acid
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K944937 | 1995-05-19 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P840051 | 1989-06-07 | MAXON(TM) POLYGLYCONATE MONOFILAMENT ABSORBABLE SU | Davis & Geck, Inc. |
| N18387 | 1987-06-18 | PDS(TM) SUTURE (CLEAR) | Ethicon, Inc. |
| N16881 | 1981-12-04 | DEXON | Davis & Geck, Inc. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.