Vicryl

Violet Monofilament (Polyglactin 910), Synthetic Absorbable Surgical Suture

Registry build 21.09.26
4manufacturers in China registered for this device type
36catalogue numbers in this listing
27510(k) clearances naming this product code
21recalls on this code

Who Else Makes It

Concentrated in Shanghai (1), Shandong (1), Beijing (1).

Chinese manufacturers registered for FDA product code GAM
Manufacturer City Province Registered as Device types
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Foosin Medical Supplies Inc.ltd Weihai Shandong Manufacturer 8
ARC Medical Supplies (Beijing) Co., Ltd. Beijing Beijing Manufacturer 7
Sichuan Innovation Technology Co., Ltd. Chengdu Sichuan Contract manufacturer 2

Record

Regulatory record for Vicryl
Listed by Ethicon, Inc., United States
FDA product code GAM
Device type Suture, Absorbable, Synthetic, Polyglycolic Acid
Device class Class 2
Regulation 21 CFR 878.4493
Establishment Contract manufacturer, Specification developer, Manufacturer, Exporter
510(k) K022269
Record published 2015-09-01
Record revised 2023-05-26 (version 8)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Storage Storage environment temperature up to 30 °C; Storage environment temperature up to 86 °F
Packaging Box of 12, box of 36, box of 24

Catalogue Numbers

Catalogue numbers for Vicryl
Catalogue number Size Status
D8760 In distribution
J5465G In distribution
VCPB752D In distribution
VCP381H In distribution
D5165 In distribution
V448G In distribution
V5495G In distribution
JJ42D In distribution
J1910T In distribution
VCP48G In distribution
VCP523H In distribution
VCP5749T In distribution
VCP693H In distribution
VCP541H In distribution
VCP385H In distribution
VCP895H In distribution
V966G In distribution
D7498 In distribution
D5792 In distribution
V950G In distribution
VCP47H In distribution
JB259H In distribution
V960G In distribution
VCP644T In distribution
VCP4849G In distribution
V402G In distribution
V449G In distribution
D9011 In distribution
J785D In distribution
VCP455H In distribution
V980G In distribution
VCP649G In distribution
J783D In distribution
VCP650G In distribution
V450G In distribution
D7329 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Novosyn B Braun Surgical SA 2,286
DemeCRYL Demetech Corp. 2,092
DemeSORB Demetech Corp. 1,625
Safil B Braun Surgical SA 1,613
Monosyn B Braun Surgical SA 1,096
E-Pack Ethicon, Inc. 967
Coated Vicryl Ethicon, Inc. 933
DemeQUICK Demetech Corp. 732
Polysorb Covidien LP 732
DemeCAPRONE Demetech Corp. 707
Wego-PGA Absorbable Surgical Suture With Needle Foosin Medical Supplies Inc.ltd 554
Safil Quick+ B Braun Surgical SA 414

Showing 12 of 463. All products under Suture, Absorbable, Synthetic, Polyglycolic Acid

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K253394 2026-06-25
K253852 2026-02-06
K252743 2025-12-22
K221744 2022-11-15
K201996 2020-12-21
K192580 2019-12-18
K183183 2019-06-27
K181652 2018-09-28
K161726 2016-07-12
K153611 2016-06-03
K151200 2015-08-13
K142822 2015-03-26
K132580 2014-02-28
K050845 2005-06-29
K033746 2003-12-18
K032420 2003-10-22
K022715 2002-12-19
K022269 2002-09-13
K974299 1998-02-13
K970317 1997-04-25
K964345 1996-12-16
K962480 1996-08-02
K946271 1995-06-15
K944110 1995-01-18
K930772 1994-01-07
K930360 1993-12-17
K915835 1992-03-23

Recalls Naming This Product

8 recalls name this product by its own identifiers, the UDI on its label or the 510(k) it is cleared under.

Recalls naming the identifiers of Vicryl
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Ethicon, Inc. 510(k) number 2024-09-25 Class II Under Investigation by firm Complaints were received regarding needle pull-off and suture degradation. Analysis on returned product from this lot confirmed that some sutures were visually degraded in the package. 31,032 units
Ethicon, Inc. 510(k) number 2024-05-10 Class II Under Investigation by firm Issue on a specific packaging machine resulted in a hole in the primary packaging, product sterility compromised and could result in infection. 341532 units
Ethicon, Inc. 510(k) number 2024-05-10 Class II Under Investigation by firm Issue on a specific packaging machine resulted in a hole in the primary packaging, product sterility compromised and could result in infection. 55296 units
Ethicon, Inc. 510(k) number 2024-05-10 Class II Under Investigation by firm Issue on a specific packaging machine resulted in a hole in the primary packaging, product sterility compromised and could result in infection. 56952 units
Ethicon, Inc. UDI-DI 2020-09-09 Class II Packaging process control Product in the foil package for VICRYL V960 may not match the foil label and sales unit carton. The correct VICRYL suture is size 10-0, 4 inches (10 cm) in length, has monofilament construction, and a single needle. The incorrect VICRYL sut 1,032 eaches (OUS only) 2023-11-07
Ethicon, Inc. 510(k) number 2020-01-03 Class II Process control Some sutures in the lot may exhibit a small section of braid fraying, which can lead to reduced tensile strength at that point. 23688 units 2021-08-13
Ethicon, Inc. 510(k) number 2009-02-02 Not classified Process control Sterility Issue: The firm decided to remove the product because it cannot assure the sterility of the products due to a failure in the sterilization process. 1,758,360 total 2009-10-21
Ethicon, Inc. 510(k) number 2006-05-04 Not classified Other Misalignment of packaging sealing platform created open seals and/or open channels in the packaging seal causing degradation of the sutures. 1157 dozens 2007-12-17

Recalls

6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-05-10 Class II Under Investigation by firm Issue on a specific packaging machine resulted in a hole in the primary packaging, product sterility compromised and could result in infection. 287892 units
2024-03-08 Class II Under Investigation by firm Degraded and unusable upon removal from the foil pouch due to exposed environmental conditions during transit and storage, compromising sterility 395 units
2022-09-20 Class II Under Investigation by firm Packages may contain a PS-1 cutting edge needle and not the intended SH taper point needle may result in more tissue trauma than is anticipated for taper point needles, which may necessitate repair 2,280 eaches
2022-03-24 Class II Employee error Affected product lots may contain the incorrect needle type/size and suture length due to component mix-up. 2808 (all OUS)
2019-03-12 Class II Packaging process control VICRYL Suture, VICRYL Plus Suture, PDS Suture- may contain product that does not match the sales unit carton and foil label. 550,681 eaches (WW) Total 2020-07-17
2017-08-17 Class II Equipment maintenance On August 17, 2017, Ethicon had decided to initiate a medical device recall
(removal) of the twenty-five (25) lots of VICRYL RAPIDETM (Polyglactin 910) Suture
that were distributed to the field. During finished goods testing, a suture damag
129,372 Eaches (Internationally) 2019-05-08
2010-04-20 Not classified Other Channels in the packaging seal that can lead to suture degradation and loss of packaging integrity. Recall Z-0021-2009 was initiated in 2008. Ethicon had decided to recall all sutures product during the may to June 2007 timeframe. 118332 eaches were sent to the US Distribution Center, of wh 2011-07-19
2009-02-02 Not classified Process control Sterility Issue: The firm decided to remove the product because it cannot assure the sterility of the products due to a failure in the sterilization process. 1,758,360 total 2009-10-21
2009-02-02 Not classified Process control Sterility Issue: The firm decided to remove the product because it cannot assure the sterility of the products due to a failure in the sterilization process. 1,758,360 total 2009-10-21
2009-02-02 Not classified Process control Sterility Issue: The firm decided to remove the product because it cannot assure the sterility of the products due to a failure in the sterilization process. 1,758,360 total 2009-10-21
2009-02-02 Not classified Process control Sterility Issue: The firm decided to remove the product because it cannot assure the sterility of the products due to a failure in the sterilization process. 1,758,360 total 2009-10-21
2008-08-11 Not classified Packaging Package defect compromised the integrity of the primary seal, which could lead to premature suture degradation and/or impair the sterile barrier of the product. 6912 2012-06-05
2006-02-16 Not classified Other The unique absorption profile of Panacryl in the suture could act as a foreign body so that surgeons should consider its use in specific situations. 1,061,712 sutures 2006-12-07

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P840051 1989-06-07 MAXON(TM) POLYGLYCONATE MONOFILAMENT ABSORBABLE SU Davis & Geck, Inc.
N18387 1987-06-18 PDS(TM) SUTURE (CLEAR) Ethicon, Inc.
N16881 1981-12-04 DEXON Davis & Geck, Inc.

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer