| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Foosin Medical Supplies Inc.ltd | Weihai | Shandong | Manufacturer | 8 |
Record
| Listed by | Ethicon, Inc., United States |
|---|---|
| FDA product code | GAQ |
| Device type | Suture, Nonabsorbable, Steel, Monofilament And Multifilament, Sterile |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4495 |
| Establishment | Contract manufacturer, Specification developer, Manufacturer, Exporter |
| 510(k) | K946173 |
| Record published | 2015-09-01 |
| Record revised | 2026-04-13 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Packaging | Box of 12, box of 6 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| D10117 | In distribution | |
| RS20 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Ethibond Excel | Ethicon, Inc. | 175 |
| DemeSTEEL | Demetech Corp. | 150 |
| Deknatel | Teleflex Medical LLC | 94 |
| Ethicon | Ethicon, Inc. | 73 |
| Steel | Covidien LP | 44 |
| Acier | Peters Surgical | 43 |
| E-Pack | Ethicon, Inc. | 17 |
| Ethi-PAK | Ethicon, Inc. | 11 |
| Steel Wire | Resorba Medical GmbH | 10 |
| Steelex | B Braun Surgical SA | 7 |
| Valkyrie | Surgical Specialties México, S. de R.L. de C.V. | 6 |
| Fumedica | Surgical Specialties México, S. de R.L. de C.V. | 6 |
Showing 12 of 26. All products under Suture, Nonabsorbable, Steel, Monofilament And Multifilament, Sterile
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K170767 | 2017-11-01 |
| K946173 | 1995-01-09 |
| K931271 | 1994-01-07 |
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Ethicon, Inc. | 510(k) number | 2019-04-19 | Class II | Material/Component Contamination | Possibility that a suture raw material containing high endotoxin levels was used in the manufacturing of this lot | 1296 eaches | 2021-02-05 |
| Ethicon, Inc. | 510(k) number | 2019-04-19 | Class II | Material/Component Contamination | Possibility that a suture raw material containing high endotoxin levels was used in the manufacturing of this lot | 36 eaches | 2021-02-05 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.