EEA
Black Extra Thick XL Circular Stapler with Tri-Staple Technology
Who Else Makes It
Concentrated in Shanghai (5), Jiangsu (5), Zhejiang (2). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Hangzhou Fushan Medical Appliance Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 44 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Zhangjiagang Municipal Cnnc Huakang Radiation Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 17 |
| Covidien Medical Products (Shanghai) Manufacturing LLC | Shanghai | Shanghai | Contract manufacturer | 8 |
| Beijing Biosis Healing Biological Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 7 |
| B.j.zh.f.panther Medical Equipment Co., Ltd. | Beijing | Beijing | Manufacturer | 6 |
| Touchstone International Medical Science Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 5 |
| Sinolinks Medical Innovation, Inc. | Changzhou | Jiangsu | Complaint-file establishment | 5 |
| Victor Medical Instruments Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 5 |
| Lucky Star Lrradiation Science Co., Ltd. Shanghai | Shanghai | Shanghai | Contract manufacturer | 5 |
| Fengh Medical Co., Ltd. | Jiangyin | Jiangsu | Manufacturer | 4 |
| Medtronic (Shanghai) Medical Technology Co., Ltd. | Min Hang District | Shanghai | Specification developer | 4 |
Showing 12 of 16. All 16 manufacturers in China registered for Staple, Implantable
Record
| Listed by | Covidien LP, United States |
|---|---|
| FDA product code | GDW |
| Device type | Staple, Implantable |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4750 |
| 510(k) | K221771 |
| Record published | 2024-05-03 |
| Record revised | 2025-06-24 (version 13) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Handling environment temperature up to 130 °F |
| Packaging | Case of 3, pack_or_inner_pack of 3, case of 6 |
| Sizes | Outer diameter 21 to 33 mm; height 3.5 to 4.8 mm; length 21 to 28 mm; width 25 mm |
| Distribution end date | 2026-03-03 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| TRIEEA21XT | Outer Diameter 21 mm | In distribution |
| TRIEEAXL33MT | Outer Diameter 33 mm | In distribution |
| TRIEEAXL21XTORVIL | Outer Diameter 21 mm | In distribution |
| EEAXL31 | Length,XL,N/A; | In distribution |
| EEAXL2835 | Outer Diameter 28 mm | In distribution |
| TRIEEA25MT | Width 25 mm | In distribution |
| TRIEEA31MT | Medium/Thick; | In distribution |
| TRIEEAXL21MT | Outer Diameter 21 mm | In distribution |
| TRIEEA28MT | Medium/Thick; | In distribution |
| TRIEEAXL25MTORVIL | 25mm; | In distribution |
| TRIEEAXL28MT | Outer Diameter 28 mm | In distribution |
| TRIEEA33MT | Outer Diameter 33 mm | In distribution |
| EEAXL2535 | Outer Diameter 25 mm | In distribution |
| EEA2535 | Length 25 mm | In distribution |
| EEA33 | Outer Diameter 33 mm | In distribution |
| EEAXL21 | Height 4.8 mm | In distribution |
| EEAXL33 | Length,XL,N/A; | In distribution |
| TRIEEA25XT | Width 25 mm | In distribution |
| HEM3335 | Height 3.5 mm | In distribution |
| EEAXL28 | Height 4.8 mm | In distribution |
| EEA25 | Length 25 mm | In distribution |
| EEA28 | Length 28 mm | In distribution |
| TRIEEAXL25XT | Width 25 mm | In distribution |
| TRIEEAXL25XTORVIL | 25mm; | In distribution |
| TRIEEAXL31MT | Outer Diameter 31 mm | In distribution |
| TRIEEAXL21XT | Outer Diameter 21 mm | In distribution |
| EEA2135 | Height 3.5 mm | In distribution |
| EEA21 | Length 21 mm | In distribution |
| EEA31 | Height 4.8 mm | In distribution |
| TRIEEAXL25MT | Width 25 mm | In distribution |
| EEAXL2135 | Outer Diameter 21 mm | In distribution |
| EEA2835 | Height 3.5 mm | In distribution |
| EEAXL25 | Height 4.8 mm | In distribution |
| 110276L | Outer Diameter 31 mm | Withdrawn |
| HEM3348 | Outer Diameter 33 mm | Withdrawn |
| 110238L | Outer Diameter 28 mm | Withdrawn |
| 110214L | Outer Diameter 25 mm | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Endo GIA | Covidien LP | 51 |
| Aeon | Lexington Medical, Inc. | 48 |
| Proximate | Ethicon Endo-Surgery, Inc. | 42 |
| Tri-Staple 2.0 | Covidien LP | 42 |
| Echelon Endopath | Ethicon Endo-Surgery, Inc. | 33 |
| Reloading Unit for Endo Linear Cutter Stapler | B.j.zh.f.panther Medical Equipment Co., Ltd. | 28 |
| GIA | Covidien LP | 24 |
| easyEndoTM Universal Linear Cutting Stapler and Loading Units for Single Use | Ezisurg Medical Co., Ltd. | 23 |
| Circular Stapler | B.j.zh.f.panther Medical Equipment Co., Ltd. | 23 |
| Endopath | Ethicon Endo-Surgery, Inc. | 22 |
| Signia | Covidien LP | 19 |
| Staple, Implantable | Ethicon Endo-Surgery, Inc. | 18 |
Showing 12 of 105. All products under Staple, Implantable
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Covidien | 510(k) number | 2018-08-17 | Class II | Process design | The firm identified the potential for a device to have an incorrect tissue gap. Use of a device with an incorrect tissue gap may result in incomplete staple formation and/or the inability to remove the device from tissue following applicati | 1,902 | 2020-04-10 |
| Covidien | 510(k) number | 2018-04-09 | Class II | Nonconforming Material/Component | There is a potential for improper welding of the yellow staple guide to the instrument. Use of a device with an improperly welded staple guide may result in improper staple formation potentially leading to bleeding or anastomotic leak. | 5547 | 2020-05-12 |
| Covidien | 510(k) number | 2018-04-09 | Class II | Nonconforming Material/Component | There is a potential for improper welding of the yellow staple guide to the instrument. Use of a device with an improperly welded staple guide may result in improper staple formation potentially leading to bleeding or anastomotic leak. | 475 | 2020-05-12 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.