RhinAer Stylus

The RhinAer Stylus (FG1393) is indicated for ENT surgery to destroy soft tissue in the nasal airway, including posterior nasal nerve regions in patients with chronic rhinitis. The FDA form…

Registry build 21.09.26

The RhinAer Stylus (FG1393) is indicated for ENT surgery to destroy soft tissue in the nasal airway, including posterior nasal nerve regions in patients with chronic rhinitis.

The FDA form marks the device for prescription use. The indication specifies the nasal-airway tissue target, procedure specialty and chronic-rhinitis population.

Listed Item

The RhinAer Stylus is a disposable handheld device capable of delivering bipolar radiofrequency energy to tissue. The RhinAer Stylus consists of a handle, shaft and treatment tip. An array of bipolar electrodes is positioned on a non-conductive tip which is attached to a handle via a non-conductive shaft. A temperature sensor is located on the tip to monitor tissue temperature. The Stylus is attached to a temperature-controlled radiofrequency generator via a flexible cable. The RhinAer Stylus treats symptoms of chronic rhinitis by modifying the tissues of the nasal airway through the use of low doses of radiofrequency energy to destroy tissue in the posterior nasal nerve regions. The low-power radiofrequency energy generates heat within the submucosal tissue, destroying local tissue, mucous cells, and glands, and creating a coagulation lesion. This destruction of tissue in posterior nasal nerve regions improves symptoms of chronic rhinitis. The RhinAer Stylus tip is temporarily inserted into the nose to access the treatment area. The procedure requires local anesthesia only.

Indicated Use

The FDA letter identifies the trade name RhinAer Stylus (FG1393), manufacturer Aerin Medical Inc. and product code GEI. The form marks the device for prescription use.

65manufacturers in China registered for this device type
3catalogue numbers in this listing
9510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Guangdong (24), Zhejiang (13), Shanghai (10). 23 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code GEI
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Hangzhou Kangji Medical Instrument Co., Ltd. Hangzhou Zhejiang Contract manufacturer 27
Modern Medical Equipment Manufacturing Ltd. Heng Li, Dongguan Guangdong Contract manufacturer 26
Amphenol Alden Products Company Shenzhen Guangdong Contract manufacturer 24
Hangzhou Endo Medical Instrument Co., Ltd. Hangzhou Zhejiang Contract manufacturer 19
Hong Qiangxing (Shen Zhen) Electronics Limited Shenzhen Guangdong Contract manufacturer 19
Shenzhen MED-Link Electronics Tech Co., Ltd. Shenzhen Guangdong Contract manufacturer 18
Sanbor Medical Xiamen, Inc. Xiamen Fujian Contract manufacturer 16
ATL Technology DG,Ltd. Dongguan Guangdong Contract manufacturer 14
Jiangyin Sinbon Electronics Co Ltd Jiangyin Jiangsu Contract manufacturer 13
Guangzhou Huada Biotechnology Co., Ltd. Guangzhou Guangdong Contract manufacturer 9

Showing 12 of 65. All 65 manufacturers in China registered for Electrosurgical, Cutting & Coagulation & Accessories

Record

Regulatory record for RhinAer Stylus
Listed by Aerin Medical Inc., United States
FDA product code GEI
Device type Electrosurgical, Cutting & Coagulation & Accessories
Device class Class 2
Regulation 21 CFR 878.4400
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K221907
Record published 2020-02-03
Record revised 2025-10-22 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Storage Storage environment temperature -18 to 60 °C; Storage environment humidity 15 to 90 % RH
Distribution end date 2025-10-01

Catalogue Numbers

Catalogue numbers for RhinAer Stylus
Catalogue number Size Status
FG2258 In distribution
FG1393 In distribution
FG815 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Surgical Direct Surgical Direct, Inc. 5,729
Speedlock National Advanced Endoscopy Devices, Inc. 5,212
Stingray Surgical Products Stingray Surgical Products L.L.C. 4,647
Kirwan Kirwan Surgical Products, LLC. 1,901
Millennium Avalign Technologies, Inc. 1,779
DANmed Dannoritzer Medizintechnik GmbH & Co. KG 1,590
Elmed Elmed, Inc. 1,519
Symmetry Olsen Aspen Surgical Products, Inc. 1,219
Guenter Bissinger Medizintechnik GmbH Günter Bissinger Medizintechnik GmbH 1,117
Ambler Surgical Ambler Surgical, LLC 756
V. Mueller Steris Corporation 661
Aesculap Aesculap AG 544

Showing 12 of 2,922. All products under Electrosurgical, Cutting & Coagulation & Accessories

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K260522 2026-05-18
K242630 2024-12-10
K221907 2022-07-29
K200300 2020-04-13
K192471 2019-12-20
K172529 2017-12-05
K162810 2017-01-11
K161994 2016-09-22
K150637 2015-11-19

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2024-11-12 Class II Under Investigation by firm Some units in a single production lot were programmed incorrectly which will result in the VivAer Stylus being incorrectly recognized as RhinAer Stylus when connected to the Aerin Console. 479 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer