Vasoview Hemopro 3 Endoscopic Vessel Harvesting System

Vasoview Hemopro 3 is an endoscopic vessel-harvesting system designed to work with a 7 mm endoscope. Its harvesting cannula contains channels for the endoscope, C-ring, lens-washer tube and…

Registry build 21.09.26

Vasoview Hemopro 3 is an endoscopic vessel-harvesting system designed to work with a 7 mm endoscope. Its harvesting cannula contains channels for the endoscope, C-ring, lens-washer tube and harvesting tool.

The filing lists system models VH-6000 and VH-6001, plus power supply VH-6010. It describes the harvesting tool as cutting and cauterizing vessel branches, with the power supply specified for use with the system.

Listed Item

The Vasoview Hemopro 3 Endoscopic Vessel Harvesting System is designed for use in conjunction with the 7 mm Endoscope. The Harvesting Cannula has four lumens which house the Endoscope, C-Ring, distal lens washer tube and Vasoview Hemopro 3 Harvesting Tool for cutting and cauterization of vessel branches. The C-Ring with the built-in distal lens washer is independently controlled by a C-Ring Slider on the handle of the Harvesting Cannula. The C-Ring cradles the vessel and delivers the saline that washes the distal tip of the Endoscope. The Harvesting Tool can be inserted, removed, rotated, extended, and retracted from the main Harvesting Cannula through the Tool Adapter Port. The Harvesting Tool is powered by direct current (DC) only; it does not utilize RF (radio frequency) energy. The Harvesting Tool cuts and cauterizes through a process of heat and pressure. The Harvesting Tool has two curved Jaws. One of the Jaws contains the heating elements for branch cutting and cauterization and spot cautery. There are three heating elements: two cauterization elements and a cutting element between them. Both Jaws have insulation protecting the adjacent tissue. The concave side of the Jaws has a larger buffer of insulation and therefore should be positioned toward sensitive tissue during Jaw activation. An area near the tip of the convex side of the Jaw can be used for spot cautery to cauterize tissue contacted by that area of the Jaw. The Activation Toggle is used to control the Jaws and to activate the heating elements. Positioning of the device, cutting, and cauterization are performed under endoscopic visualization. This device is intended for specific use with the Vasoview Hemopro Power Supply and Vasoview Hemopro 3 Power Adapter.

System Components

The filing lists VH-6000 and VH-6001 harvesting systems and VH-6010 as the associated power supply.

65manufacturers in China registered for this device type
2catalogue numbers in this listing
8510(k) clearances naming this product code
23recalls on this code

Who Else Makes It

Concentrated in Guangdong (24), Zhejiang (13), Shanghai (10). 23 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code GEI
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Hangzhou Kangji Medical Instrument Co., Ltd. Hangzhou Zhejiang Contract manufacturer 27
Modern Medical Equipment Manufacturing Ltd. Heng Li, Dongguan Guangdong Contract manufacturer 26
Amphenol Alden Products Company Shenzhen Guangdong Contract manufacturer 24
Hangzhou Endo Medical Instrument Co., Ltd. Hangzhou Zhejiang Contract manufacturer 19
Hong Qiangxing (Shen Zhen) Electronics Limited Shenzhen Guangdong Contract manufacturer 19
Shenzhen MED-Link Electronics Tech Co., Ltd. Shenzhen Guangdong Contract manufacturer 18
Sanbor Medical Xiamen, Inc. Xiamen Fujian Contract manufacturer 16
ATL Technology DG,Ltd. Dongguan Guangdong Contract manufacturer 14
Jiangyin Sinbon Electronics Co Ltd Jiangyin Jiangsu Contract manufacturer 13
Guangzhou Huada Biotechnology Co., Ltd. Guangzhou Guangdong Contract manufacturer 9

Showing 12 of 65. All 65 manufacturers in China registered for Electrosurgical, Cutting & Coagulation & Accessories

Record

Regulatory record for Vasoview Hemopro 3 Endoscopic Vessel Harvesting System
Listed by Maquet Cardiovascular LLC, United States
FDA product code GEI
Device type Electrosurgical, Cutting & Coagulation & Accessories
Device class Class 2
Regulation 21 CFR 878.4400
Establishment Specification developer, Manufacturer
510(k) K251238
Record published 2024-05-21
Record revised 2025-06-20 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Vasoview Hemopro 3 Endoscopic Vessel Harvesting System
Catalogue number Size Status
VH-6000 In distribution
VH-6001 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Surgical Direct Surgical Direct, Inc. 5,729
Speedlock National Advanced Endoscopy Devices, Inc. 5,212
Stingray Surgical Products Stingray Surgical Products L.L.C. 4,647
Kirwan Kirwan Surgical Products, LLC. 1,901
Millennium Avalign Technologies, Inc. 1,779
DANmed Dannoritzer Medizintechnik GmbH & Co. KG 1,590
Elmed Elmed, Inc. 1,519
Symmetry Olsen Aspen Surgical Products, Inc. 1,219
Guenter Bissinger Medizintechnik GmbH Günter Bissinger Medizintechnik GmbH 1,117
Ambler Surgical Ambler Surgical, LLC 756
V. Mueller Steris Corporation 661
Aesculap Aesculap AG 544

Showing 12 of 2,922. All products under Electrosurgical, Cutting & Coagulation & Accessories

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K251238 2025-05-30
K243918 2025-02-26
K233879 2024-02-27
K191947 2019-09-17
K153194 2016-04-19
K132743 2013-12-03
K101274 2010-06-11
K091733 2009-08-28

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Vasoview Hemopro 3 Endoscopic Vessel Harvesting System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Maquet Cardiovascular LLC 510(k) number 2025-08-06 Class II Under Investigation by firm Reports of out-of-box failures discovered during the limited launch phase. Failure modes included angled deformity at the attachment site of the Harvesting Tool Jaws and the distal end of the Harvesting Tool Shaft, jaws not fully closed out 98 units

Recalls

3 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-06-02 Class II Under Investigation by firm Getinge identified that Vasoview Hemopro 2 devices from Lot 3000547797 were exposed to an out-of-specification sterilization dose during a gamma sterilization run (Run ID 1183-28782A) performed by STERIS at its Whippany, NJ facility between 205 units
2025-03-20 Class II Under Investigation by firm There have been at least 12 complaints from users as of March 3, 2025, reporting that they identified the ceramic C-Ring to be broken in half during use of the device. The ceramic C-Ring has a potential to break while in use. Maquet/Getinge 22,244 units
2025-03-10 Class II Under Investigation by firm Incorrect resistor utilized in the VH-3010 Power Supply, which may cause the jaws of the HemoPro 2 to not adequately heat up. 110 units
2024-12-09 Class I Device Design Potential for two issues:
1. Bent or detached heater wire;
2. Silicone peeling or detaching from the Jaws of the Harvesting Tool
11,101 units US
2024-12-09 Class I Device Design Potential for two issues:
1. Bent or detached heater wire;
2. Silicone peeling or detaching from the Jaws of the Harvesting Tool
418,076 units (326,608 US, 91,468 OUS)
2024-09-20 Class I Device Design There were reports of the silicone detaching from the Jaws of the Harvesting Tool during use. 28,809 units
2024-05-31 Class II Under Investigation by firm There were 27 complaints between March 22, 2024, and April 30, 2024, related to VH-3500 and VH-4000, reporting that the C-Ring wire was straightened (due to insufficient bend radius) and that the distance between C-Ring and Harvesting Tool 2463 units units US /330 units OUS
2024-05-31 Class II Under Investigation by firm There were 27 complaints between March 22, 2024, and April 30, 2024, related to VH-3500 and VH-4000, reporting that the C-Ring wire was straightened (due to insufficient bend radius) and that the distance between C-Ring and Harvesting Tool 600 units
2024-05-17 Class II Device Design Potential for there to be a fluid ingress into the handle of the harvesting tool, which may lead to the device not providing cautery or providing cautery when not intended. 430,037 units
2024-05-17 Class II Device Design Potential for there to be a fluid ingress into the handle of the harvesting tool, which may lead to the device not providing cautery or providing cautery when not intended. 37,186 units
2023-12-01 Class II Component design/selection Risk of polyimide particulate matter being present on the endoscopic harvesting vessel system. This issue may result in polyimide particulate matter being introduced into the arterial conduit for patients undergoing a coronary artery bypas 38,094 units (US)
2023-12-01 Class II Component design/selection Risk of polyimide particulate matter being present on the endoscopic harvesting vessel system. This issue may result in polyimide particulate matter being introduced into the arterial conduit for patients undergoing a coronary artery bypas 554 units (OUS)
2023-09-19 Class II Under Investigation by firm Device packaged inside an incorrect outer box; displaying artwork & illustrations for a different device.
2023-03-06 Class II Process control Some batches of product were not sterilized to their minimum sterilization specification. 900 units
2023-03-06 Class II Process control Some batches of product were not sterilized to their minimum sterilization specification. 235 units
2023-03-06 Class II Process control Some batches of product were not sterilized to their minimum sterilization specification. 2300 units
2022-12-22 Class II Under Investigation by firm Ink on the Vasoshield syringe Maquet logo may chip resulting in an unreasonable risk of harm to the patient. Potential harms may include foreign body reaction, coronary embolic event, and peripheral embolic event. 9817 devices
2017-01-27 Class II Under Investigation by firm Maquet has received several complaints involving the VASOVIEW HEMOPRO VH-3500 which involve the device exhibiting the failure mode of intermittent or no power. 4283 units 2018-04-12
2013-10-30 Class II Component design/selection Maquet has received an increase in the number of complaints for “self-activated/remains activated/overheats” for the Hemopro VH-30000, “Hemopro 1” 12,259 units 2015-04-24
2009-12-17 Not classified Nonconforming Material/Component During routine production quality monitoring process, it was found that UV curing adhesive was not used in a limited number of devices. 72 units 2011-09-21
2009-12-17 Not classified Nonconforming Material/Component During routine production quality monitoring process, it was found that UV curing adhesive was not used in a limited number of devices. 141 units 2011-09-21
2009-12-17 Not classified Nonconforming Material/Component During routine production quality monitoring process, it was found that UV curing adhesive was not used in a limited number of devices. 177 units 2011-09-21

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer