Venclose Maven Catheter

The Venclose Maven Catheter delivers radiofrequency energy inside veins with perforator or tributary reflux. It is used with the digiRF generator for endovascular coagulation. Heating the…

Registry build 21.09.26

The Venclose Maven Catheter delivers radiofrequency energy inside veins with perforator or tributary reflux. It is used with the digiRF generator for endovascular coagulation. Heating the vein wall denatures collagen and closes the treated vessel as part of the ablation procedure.

The catheter has a 6 French shaft, a 40 centimetre insertable length and a 0.5 centimetre heating coil. An integrated cable connects it to the generator, which supplies temperature controlled energy and sets the treatment parameters automatically.

Listed Item

Venclose Perforator Catheter

Single Use Catheter

The catheter is supplied sterile and is discarded after one use. Its shaft, handle and integrated connector cable form the patient contacting delivery component, while the reusable generator supplies energy and controls.

65manufacturers in China registered for this device type
1catalogue number
4510(k) clearances naming this product code

Who Else Makes It

Concentrated in Guangdong (24), Zhejiang (13), Shanghai (10). 23 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code GEI
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Hangzhou Kangji Medical Instrument Co., Ltd. Hangzhou Zhejiang Contract manufacturer 27
Modern Medical Equipment Manufacturing Ltd. Heng Li, Dongguan Guangdong Contract manufacturer 26
Amphenol Alden Products Company Shenzhen Guangdong Contract manufacturer 24
Hangzhou Endo Medical Instrument Co., Ltd. Hangzhou Zhejiang Contract manufacturer 19
Hong Qiangxing (Shen Zhen) Electronics Limited Shenzhen Guangdong Contract manufacturer 19
Shenzhen MED-Link Electronics Tech Co., Ltd. Shenzhen Guangdong Contract manufacturer 18
Sanbor Medical Xiamen, Inc. Xiamen Fujian Contract manufacturer 16
ATL Technology DG,Ltd. Dongguan Guangdong Contract manufacturer 14
Jiangyin Sinbon Electronics Co Ltd Jiangyin Jiangsu Contract manufacturer 13
Guangzhou Huada Biotechnology Co., Ltd. Guangzhou Guangdong Contract manufacturer 9

Showing 12 of 65. All 65 manufacturers in China registered for Electrosurgical, Cutting & Coagulation & Accessories

Record

Regulatory record for Venclose Maven Catheter
Listed by Venclose, Inc., United States
FDA product code GEI
Device type Electrosurgical, Cutting & Coagulation & Accessories
Device class Class 2
Regulation 21 CFR 878.4400
Establishment Manufacturer
510(k) K211806
Record published 2021-09-01
Record revised 2024-04-11 (version 2)

Specifications

Specifications
MRI safety MR Unsafe
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Packaging Box of 5, box of 10

Catalogue Numbers

Catalogue numbers for Venclose Maven Catheter
Catalogue number Size Status
VC056F In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Surgical Direct Surgical Direct, Inc. 5,729
Speedlock National Advanced Endoscopy Devices, Inc. 5,212
Stingray Surgical Products Stingray Surgical Products L.L.C. 4,647
Kirwan Kirwan Surgical Products, LLC. 1,901
Millennium Avalign Technologies, Inc. 1,779
DANmed Dannoritzer Medizintechnik GmbH & Co. KG 1,590
Elmed Elmed, Inc. 1,519
Symmetry Olsen Aspen Surgical Products, Inc. 1,219
Guenter Bissinger Medizintechnik GmbH Günter Bissinger Medizintechnik GmbH 1,117
Ambler Surgical Ambler Surgical, LLC 756
V. Mueller Steris Corporation 661
Aesculap Aesculap AG 544

Showing 12 of 2,922. All products under Electrosurgical, Cutting & Coagulation & Accessories

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252316 2025-08-19
K250068 2025-02-04
K211806 2021-08-03
K160754 2016-09-09

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Venclose Maven Catheter
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Bard Peripheral Vascular, Inc. 510(k) number 2025-08-21 Class II Software Design Change Software version 3.35 of the Venclose digiRF Generator incorporates a catheter verification feature specifically designed to detect internal wiring anomalies in Venclose EVSRF Ablation Catheters prior to clinical use. This automated diagnos 1,725

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer