Wet-Field®
Single Use Bipolar Cable
Who Else Makes It
Concentrated in Guangdong (24), Zhejiang (13), Shanghai (10). 23 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Hangzhou Kangji Medical Instrument Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 27 |
| Modern Medical Equipment Manufacturing Ltd. | Heng Li, Dongguan | Guangdong | Contract manufacturer | 26 |
| Amphenol Alden Products Company | Shenzhen | Guangdong | Contract manufacturer | 24 |
| Hangzhou Endo Medical Instrument Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 19 |
| Hong Qiangxing (Shen Zhen) Electronics Limited | Shenzhen | Guangdong | Contract manufacturer | 19 |
| Shenzhen MED-Link Electronics Tech Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 18 |
| Sanbor Medical Xiamen, Inc. | Xiamen | Fujian | Contract manufacturer | 16 |
| ATL Technology DG,Ltd. | Dongguan | Guangdong | Contract manufacturer | 14 |
| Jiangyin Sinbon Electronics Co Ltd | Jiangyin | Jiangsu | Contract manufacturer | 13 |
| Guangzhou Huada Biotechnology Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 9 |
Showing 12 of 65. All 65 manufacturers in China registered for Electrosurgical, Cutting & Coagulation & Accessories
Record
| Listed by | Beaver-Visitec International, Ltd, United Kingdom |
|---|---|
| FDA product code | GEI |
| Device type | Electrosurgical, Cutting & Coagulation & Accessories |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4400 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| Record published | 2016-09-21 |
| Record revised | 2023-04-04 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Ethylene Oxide |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Storage | Special storage condition: Store in a dry place. |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 221208 | In distribution | ||
| 221211 | In distribution | ||
| 221206 | In distribution | ||
| 221270 | 5 | In distribution | |
| 22135050 | 50 | In distribution | |
| 221209 | In distribution | ||
| 221207 | In distribution | ||
| 221204 | In distribution | ||
| 22155010 | 10 | In distribution | |
| 22135010 | 10 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Surgical Direct | Surgical Direct, Inc. | 5,729 |
| Speedlock | National Advanced Endoscopy Devices, Inc. | 5,212 |
| Stingray Surgical Products | Stingray Surgical Products L.L.C. | 4,647 |
| Kirwan | Kirwan Surgical Products, LLC. | 1,901 |
| Millennium | Avalign Technologies, Inc. | 1,779 |
| DANmed | Dannoritzer Medizintechnik GmbH & Co. KG | 1,590 |
| Elmed | Elmed, Inc. | 1,519 |
| Symmetry Olsen | Aspen Surgical Products, Inc. | 1,219 |
| Guenter Bissinger Medizintechnik GmbH | Günter Bissinger Medizintechnik GmbH | 1,117 |
| Ambler Surgical | Ambler Surgical, LLC | 756 |
| V. Mueller | Steris Corporation | 661 |
| Aesculap | Aesculap AG | 544 |
Showing 12 of 2,922. All products under Electrosurgical, Cutting & Coagulation & Accessories
Recalls Naming This Product
1 recall names this product by its own identifier, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Beaver-Visitec International, Ltd | UDI-DI | 2018-02-26 | Class II | Process control | Incorrect tip was used during manufacturing of the Osher Thermodot Marker. The markers have a needle tip instead of the proper flat tip. | 110 total products | 2019-01-28 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2022-04-26 | Class II | Under Investigation by firm | Boxes labeled as Wet-Field Eraser, 18GA Blunt Tip, 45Deg., were shipped containing incorrect product a Wet-Field Eraser, 18GA Bevel Tip, Straight, Part Number: 221250 | 660 units | |
| 2018-02-26 | Class II | Labeling mix-ups | Products were packaged with incorrect labeling, | 1025 | 2019-10-30 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.