Advantage Power Plus
ADVNATAGE G 110V (ADVANTAGE laser console)
Who Else Makes It
Concentrated in Beijing (28), Guangdong (21), Hebei (13). 11 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Sanbor Medical Xiamen, Inc. | Xiamen | Fujian | Contract manufacturer | 16 |
| Beijing Winkonlaser Technology Limited | Beijing | Beijing | Contract manufacturer | 14 |
| Changsha Gomecy Electronics Co., Ltd. | Changsha | Hunan | Contract manufacturer | 9 |
| Gymmax Technology Shenzhen Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Guangzhou Niansheng Beauty Equipment Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 7 |
| Beijing Syntech Laser Co., Ltd. | Beijing | Beijing | Contract manufacturer | 5 |
| VTech Communications Ltd | Dongguan | Guangdong | Contract manufacturer | 5 |
| Wuhan Dimed Laser Technology Co., Ltd. | Wuhan | Hubei | Contract manufacturer | 3 |
| Chengdu Vantron Technology Co., Ltd. | Chengdu | Sichuan | Contract manufacturer | 1 |
| Shanghai Shengguang Science & Technology Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 1 |
| Guilin Woodpecker Medical Instrument Co., Ltd. | Guilin | Guangxi | Manufacturer | 25 |
Showing 12 of 92. All 92 manufacturers in China registered for Powered Laser Surgical Instrument
Record
| Listed by | Lutronic Corporation, South Korea |
|---|---|
| FDA product code | GEX |
| Device type | Powered Laser Surgical Instrument |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4810 |
| Establishment | Manufacturer, Exporter |
| Record published | 2016-09-09 |
| Record revised | 2023-06-19 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | serial number |
| Storage | Storage environment temperature 10 to 40 °C; Storage environment humidity 30 to 70 % RH; Handling environment temperature 20 to 30 °C; Handling environment humidity 30 to 70 % RH |
| Packaging | Carton case |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| ADVNATAGE G 110V | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Accu-Beam | Transamerican Technologies International | 181 |
| Powered Laser Surgical Instrument | Weinert Fiber Optics Inc. | 117 |
| Waterlase Laser Tips | Biolase Technology, Inc. | 112 |
| ProFlex™ | Innovaquartz LLC | 109 |
| Dornier MedTech | Dornier Medtech America, Inc. | 91 |
| Powered Laser Surgical Instrument | Ophthalmed LLC | 90 |
| Optilite | Convergent Laser Technologies | 87 |
| Reusable Surgical Optical Fiber | Quanta System Spa | 78 |
| Single use Surgical Optical Fiber | Quanta System Spa | 70 |
| Powered Laser Surgical Instrument | Lutronic Corporation | 57 |
| Waterlase iPlus Dental Laser System | Biolase Technology, Inc. | 53 |
| Leoni™ | Weinert Fiber Optics Inc. | 49 |
Showing 12 of 2,654. All products under Powered Laser Surgical Instrument
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K213569 | 2022-02-04 |
| K203788 | 2021-03-26 |
| K183566 | 2019-06-14 |
| K173700 | 2018-06-19 |
| K171009 | 2017-06-23 |
| K163196 | 2017-05-24 |
| K141555 | 2014-11-06 |
| K130199 | 2013-11-22 |
| K113502 | 2012-04-05 |
| K113588 | 2012-02-22 |
| K103455 | 2011-04-28 |
| K101573 | 2010-09-23 |
| K091115 | 2009-10-30 |
| K091320 | 2009-08-19 |
| K082096 | 2008-10-08 |
| K080496 | 2008-07-07 |
| K080932 | 2008-06-09 |
| K080248 | 2008-04-23 |
| K073436 | 2007-12-28 |
| K070392 | 2007-07-13 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2026-08-06 | Not classified | Device Design | Utilizing higher fluences at 1064nm wavelength with current cryogen parameters may result in a spark/loud noise during treatment, potentially resulting in patient burn. | 1065 |
| 2026-01-27 | Class II | Device Design | Reports of devices sparking/popping and potentially burning patients. | 1,525 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.