The Iridex® 532 (532, green) Laser Console is a solid-state laser that is used to deliver laser energy in Continuous-Wave for ear, nose and throat (ENT) applications, and in Continuous-Wave…

Registry build 21.09.26

The Iridex® 532 (532, green) Laser Console is a solid-state laser that is used to deliver laser energy in Continuous-Wave for ear, nose and throat (ENT) applications, and in Continuous-Wave and MicroPulse® modes for ophthalmic applications.

92manufacturers in China registered for this device type
1catalogue number
14510(k) clearances naming this product code
1recall

Who Else Makes It

Concentrated in Beijing (28), Guangdong (21), Hebei (13). 11 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code GEX
Manufacturer City Province Registered as Device types
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31
Sanbor Medical Xiamen, Inc. Xiamen Fujian Contract manufacturer 16
Beijing Winkonlaser Technology Limited Beijing Beijing Contract manufacturer 14
Changsha Gomecy Electronics Co., Ltd. Changsha Hunan Contract manufacturer 9
Gymmax Technology Shenzhen Co., Ltd. Shenzhen Guangdong Contract manufacturer 8
Guangzhou Niansheng Beauty Equipment Co., Ltd. Guangzhou Guangdong Contract manufacturer 7
Beijing Syntech Laser Co., Ltd. Beijing Beijing Contract manufacturer 5
VTech Communications Ltd Dongguan Guangdong Contract manufacturer 5
Wuhan Dimed Laser Technology Co., Ltd. Wuhan Hubei Contract manufacturer 3
Chengdu Vantron Technology Co., Ltd. Chengdu Sichuan Contract manufacturer 1
Shanghai Shengguang Science & Technology Co., Ltd. Shanghai Shanghai Contract manufacturer 1
Guilin Woodpecker Medical Instrument Co., Ltd. Guilin Guangxi Manufacturer 25

Showing 12 of 92. All 92 manufacturers in China registered for Powered Laser Surgical Instrument

Record

Regulatory record for Iridex 532 Laser
Listed by Iridex Corporation, United States
FDA product code GEX
Device type Powered Laser Surgical Instrument
Device class Class 2
Regulation 21 CFR 878.4810
Establishment Repacker / relabeller, Manufacturer
510(k) K230228
Record published 2024-01-18
Record revised 2025-05-22 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Handling environment temperature 10 to 35 °C; Storage environment temperature -20 to 55 °C; Storage environment atmospheric pressure 500 to 1060 millibar; Handling environment humidity 20 to 80 % RH

Catalogue Numbers

Catalogue numbers for Iridex 532 Laser
Catalogue number Size Status
23000 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Accu-Beam Transamerican Technologies International 181
Powered Laser Surgical Instrument Weinert Fiber Optics Inc. 117
Waterlase Laser Tips Biolase Technology, Inc. 112
ProFlex™ Innovaquartz LLC 109
Dornier MedTech Dornier Medtech America, Inc. 91
Powered Laser Surgical Instrument Ophthalmed LLC 90
Optilite Convergent Laser Technologies 87
Reusable Surgical Optical Fiber Quanta System Spa 78
Single use Surgical Optical Fiber Quanta System Spa 70
Powered Laser Surgical Instrument Lutronic Corporation 57
Waterlase iPlus Dental Laser System Biolase Technology, Inc. 53
Leoni™ Weinert Fiber Optics Inc. 49

Showing 12 of 2,654. All products under Powered Laser Surgical Instrument

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K181662 2018-09-05
K170718 2017-05-03
K162416 2016-09-29
K143154 2015-01-02
K121475 2012-11-28
K071687 2008-08-07
K062369 2006-11-08
K060905 2006-05-31
K050562 2005-04-14
K041930 2004-09-10
K022228 2002-10-08
K020849 2002-05-20
K992298 1999-12-09
K982031 1998-09-08

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-02-27 Class II Device Design It was discovered that the laser energy was not going where intended to put it, resulting in focal cataracts and iris burns. US – 58 OUS – 46 2023-09-22

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer