Olympus
TFL Fiber Stripper 550 Micron Non-Sterile, Single Use Soltive
Who Else Makes It
Concentrated in Beijing (28), Guangdong (21), Hebei (13). 11 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Sanbor Medical Xiamen, Inc. | Xiamen | Fujian | Contract manufacturer | 16 |
| Beijing Winkonlaser Technology Limited | Beijing | Beijing | Contract manufacturer | 14 |
| Changsha Gomecy Electronics Co., Ltd. | Changsha | Hunan | Contract manufacturer | 9 |
| Gymmax Technology Shenzhen Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Guangzhou Niansheng Beauty Equipment Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 7 |
| Beijing Syntech Laser Co., Ltd. | Beijing | Beijing | Contract manufacturer | 5 |
| VTech Communications Ltd | Dongguan | Guangdong | Contract manufacturer | 5 |
| Wuhan Dimed Laser Technology Co., Ltd. | Wuhan | Hubei | Contract manufacturer | 3 |
| Chengdu Vantron Technology Co., Ltd. | Chengdu | Sichuan | Contract manufacturer | 1 |
| Shanghai Shengguang Science & Technology Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 1 |
| Guilin Woodpecker Medical Instrument Co., Ltd. | Guilin | Guangxi | Manufacturer | 25 |
Showing 12 of 92. All 92 manufacturers in China registered for Powered Laser Surgical Instrument
Record
| Listed by | Gyrus Acmi, Inc., United States |
|---|---|
| FDA product code | GEX |
| Device type | Powered Laser Surgical Instrument |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4810 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K242191 |
| Record published | 2025-02-24 |
| Record revised | 2026-04-27 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Packaging | Pack of 5 |
| Distribution end date | 2026-03-25 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| TFL-AFS550-NS | In distribution | ||
| TFL-FBX940RE | In distribution | ||
| TFL-FBX150RE | In distribution | ||
| TFL-AFS150-NS | In distribution | ||
| TFL-FBX940SE | In distribution | ||
| TFL-FBX200BSE | In distribution | ||
| TFL-AFS200-NS | In distribution | ||
| TFL-FBX365SE | In distribution | ||
| TFL-FBX550RE | In distribution | ||
| TFL-AFS365-NS | In distribution | ||
| TFL-FBX200RE | In distribution | ||
| TFL-AFS940-NS | In distribution | ||
| TFL-FBX365RE | In distribution | ||
| TFL-AFC-NS | 5 | In distribution | |
| TFL-FBX150SE | In distribution | ||
| TFL-FBX550SE | In distribution | ||
| TFL-FBX150BSE | In distribution | ||
| 3998-100 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Accu-Beam | Transamerican Technologies International | 181 |
| Powered Laser Surgical Instrument | Weinert Fiber Optics Inc. | 117 |
| Waterlase Laser Tips | Biolase Technology, Inc. | 112 |
| ProFlex™ | Innovaquartz LLC | 109 |
| Dornier MedTech | Dornier Medtech America, Inc. | 91 |
| Powered Laser Surgical Instrument | Ophthalmed LLC | 90 |
| Optilite | Convergent Laser Technologies | 87 |
| Reusable Surgical Optical Fiber | Quanta System Spa | 78 |
| Single use Surgical Optical Fiber | Quanta System Spa | 70 |
| Powered Laser Surgical Instrument | Lutronic Corporation | 57 |
| Waterlase iPlus Dental Laser System | Biolase Technology, Inc. | 53 |
| Leoni™ | Weinert Fiber Optics Inc. | 49 |
Showing 12 of 2,654. All products under Powered Laser Surgical Instrument
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K221306 | 2023-01-27 |
| K211401 | 2021-06-03 |
Recalls Naming This Product
7 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Olympus Corporation of the Americas | 510(k) number | 2026-02-27 | Class II | Process control | Following a complaint investigation, Olympus identified a potential defect in the 24V power supply module in some SOLTIVE laser units which may cause the system to become inoperable. Additionally, smoke or a burning smell may occur. By desi | 408 units |
| Olympus Corporation of the Americas | 510(k) number | 2026-02-27 | Class II | Process control | Following a complaint investigation, Olympus identified a potential defect in the 24V power supply module in some SOLTIVE laser units which may cause the system to become inoperable. Additionally, smoke or a burning smell may occur. By desi | 32 units |
| Olympus Corporation of the Americas | 510(k) number | 2025-05-06 | Class II | Under Investigation by firm | Potential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or contributes to, these thermal incidents. | 201 units (100 US, 101 OUS) |
| Olympus Corporation of the Americas | 510(k) number | 2025-05-06 | Class II | Under Investigation by firm | Potential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or contributes to, these thermal incidents. | 1549 units (1025 US, 524 OUS) |
| Olympus Corporation of the Americas | 510(k) number | 2025-05-06 | Class II | Under Investigation by firm | Potential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or contributes to, these thermal incidents. | 551,154 units (417859 US, 133710 OUS) |
| Olympus Corporation of the Americas | 510(k) number | 2025-05-06 | Class II | Under Investigation by firm | Potential for thermal incident including an unexpected occurrence of smoke, sparks, burning, or unsteady flames during clinical use. The fracturing of the fiber is the cause of, or contributes to, these thermal incidents. | 2,675 units (190 US, 2485 OUS) |
| Olympus Corporation of the Americas | 510(k) number | 2025-04-04 | Class II | Unknown/Undetermined by firm | Preset treatment parameters are not consistently being used in accordance with the IFU. | 189 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.