Pharos
A mains electricity (AC-powered) Light Amplification by Stimulated Emission of Radiation (LASER) device assembly in which input energy is used to excite dimers (typically rare gas…
A mains electricity (AC-powered) Light Amplification by Stimulated Emission of Radiation (LASER) device assembly in which input energy is used to excite dimers (typically rare gas monohalides such as argon fluoride, xenon chloride) as the active medium to emit a beam of intense, coherent, monochromatic electromagnetic (EM) radiation (UVA and/or UVB) for dermal phototherapy. It typically includes a light source, delivery/positioning device(s), and controls/foot-switch. It is typically intended to treat disorders such as psoriasis, vitiligo, atopic dermatitis, and leukoderma
Who Else Makes It
Concentrated in Beijing (28), Guangdong (21), Hebei (13). 11 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Jabil Circuit (Shanghai) Ltd. | Shanghai | Shanghai | Contract manufacturer | 31 |
| Sanbor Medical Xiamen, Inc. | Xiamen | Fujian | Contract manufacturer | 16 |
| Beijing Winkonlaser Technology Limited | Beijing | Beijing | Contract manufacturer | 14 |
| Changsha Gomecy Electronics Co., Ltd. | Changsha | Hunan | Contract manufacturer | 9 |
| Gymmax Technology Shenzhen Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Guangzhou Niansheng Beauty Equipment Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 7 |
| Beijing Syntech Laser Co., Ltd. | Beijing | Beijing | Contract manufacturer | 5 |
| VTech Communications Ltd | Dongguan | Guangdong | Contract manufacturer | 5 |
| Wuhan Dimed Laser Technology Co., Ltd. | Wuhan | Hubei | Contract manufacturer | 3 |
| Chengdu Vantron Technology Co., Ltd. | Chengdu | Sichuan | Contract manufacturer | 1 |
| Shanghai Shengguang Science & Technology Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 1 |
| Guilin Woodpecker Medical Instrument Co., Ltd. | Guilin | Guangxi | Manufacturer | 25 |
Showing 12 of 92. All 92 manufacturers in China registered for Powered Laser Surgical Instrument
Record
| Listed by | Catheter Precision, Incorporated, United States |
|---|---|
| FDA product code | GEX |
| Device type | Powered Laser Surgical Instrument |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4810 |
| Establishment | Specification developer, Complaint-file establishment, Manufacturer |
| 510(k) | K062963 |
| Record published | 2017-05-04 |
| Record revised | 2025-07-02 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| EX-308 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Accu-Beam | Transamerican Technologies International | 181 |
| Powered Laser Surgical Instrument | Weinert Fiber Optics Inc. | 117 |
| Waterlase Laser Tips | Biolase Technology, Inc. | 112 |
| ProFlex™ | Innovaquartz LLC | 109 |
| Dornier MedTech | Dornier Medtech America, Inc. | 91 |
| Powered Laser Surgical Instrument | Ophthalmed LLC | 90 |
| Optilite | Convergent Laser Technologies | 87 |
| Reusable Surgical Optical Fiber | Quanta System Spa | 78 |
| Single use Surgical Optical Fiber | Quanta System Spa | 70 |
| Powered Laser Surgical Instrument | Lutronic Corporation | 57 |
| Waterlase iPlus Dental Laser System | Biolase Technology, Inc. | 53 |
| Leoni™ | Weinert Fiber Optics Inc. | 49 |
Showing 12 of 2,654. All products under Powered Laser Surgical Instrument
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Ra Medical Systems,Inc | 510(k) number | 2019-08-23 | Class II | Software change control | At doses of less than 100 mJ, in custom and auto repeat modes, a software error in the excimer laser phototherapy system causes the device to fail to cease firing as long as the foot pedal or handpiece switch is depressed. This malfunction | 10 | 2021-05-05 |
| Ra Medical Systems,Inc | 510(k) number | 2014-06-30 | Class II | Error in labeling | RA Medical Systems is recalling the PHAROS EX-308 Excimer Laser because there is a possibility that the laser may calibrate with the iris closed. | 435 units | 2014-09-09 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.