Powered Laser Surgical Instrument-Diode Laser Model

The DLH-06 Diode Laser is a dermatological laser system for hair removal and permanent hair reduction. It delivers 808 nm infrared laser energy through a handpiece, with a footswitch used…

Registry build 21.09.26

The DLH-06 Diode Laser is a dermatological laser system for hair removal and permanent hair reduction. It delivers 808 nm infrared laser energy through a handpiece, with a footswitch used to activate emission. Its intended skin range includes Fitzpatrick types I through VI, including tanned skin.

Melanin in the hair and follicle absorbs the laser energy, converting it to heat. The handpiece’s sapphire contact surface provides cooling during treatment. The system combines a power supply, central controls, cooling and laser delivery components.

Treatment Modes

The system offers Standard and FHR modes for hair removal and reduction. FHR uses shorter, more frequent pulses, while Standard mode allows a wider pulse-duration range. The handpiece has a 1.2 cm² treatment spot.

92manufacturers in China registered for this device type
1catalogue number
3510(k) clearances naming this product code
8recalls on this code

Who Else Makes It

Concentrated in Beijing (28), Guangdong (21), Hebei (13). 11 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code GEX
Manufacturer City Province Registered as Device types
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31
Sanbor Medical Xiamen, Inc. Xiamen Fujian Contract manufacturer 16
Beijing Winkonlaser Technology Limited Beijing Beijing Contract manufacturer 14
Changsha Gomecy Electronics Co., Ltd. Changsha Hunan Contract manufacturer 9
Gymmax Technology Shenzhen Co., Ltd. Shenzhen Guangdong Contract manufacturer 8
Guangzhou Niansheng Beauty Equipment Co., Ltd. Guangzhou Guangdong Contract manufacturer 7
Beijing Syntech Laser Co., Ltd. Beijing Beijing Contract manufacturer 5
VTech Communications Ltd Dongguan Guangdong Contract manufacturer 5
Wuhan Dimed Laser Technology Co., Ltd. Wuhan Hubei Contract manufacturer 3
Chengdu Vantron Technology Co., Ltd. Chengdu Sichuan Contract manufacturer 1
Shanghai Shengguang Science & Technology Co., Ltd. Shanghai Shanghai Contract manufacturer 1
Guilin Woodpecker Medical Instrument Co., Ltd. Guilin Guangxi Manufacturer 25

Showing 12 of 92. All 92 manufacturers in China registered for Powered Laser Surgical Instrument

Record

Regulatory record for Powered Laser Surgical Instrument-Diode Laser Model
Listed by Beijing Syntech Laser Co., Ltd., China
FDA product code GEX
Device type Powered Laser Surgical Instrument
Device class Class 2
Regulation 21 CFR 878.4810
Establishment Contract manufacturer, Manufacturer
510(k) K123483
Record published 2017-06-29
Record revised 2025-05-22 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Powered Laser Surgical Instrument-Diode Laser Model
Catalogue number Size Status
DLH-06 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Accu-Beam Transamerican Technologies International 181
Powered Laser Surgical Instrument Weinert Fiber Optics Inc. 117
Waterlase Laser Tips Biolase Technology, Inc. 112
ProFlex™ Innovaquartz LLC 109
Dornier MedTech Dornier Medtech America, Inc. 91
Powered Laser Surgical Instrument Ophthalmed LLC 90
Optilite Convergent Laser Technologies 87
Reusable Surgical Optical Fiber Quanta System Spa 78
Single use Surgical Optical Fiber Quanta System Spa 70
Powered Laser Surgical Instrument Lutronic Corporation 57
Waterlase iPlus Dental Laser System Biolase Technology, Inc. 53
Leoni™ Weinert Fiber Optics Inc. 49

Showing 12 of 2,654. All products under Powered Laser Surgical Instrument

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K123483 2013-04-21
K113018 2012-12-14
K110434 2011-04-19

Recalls

8 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2017-07-03 Class II Nonconforming Material/Component The noncompliance is that the certification label was not affixed on the product, with statement “Complies with 21 CFR 1040.10 and
1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007″.
3
2017-07-03 Class II Nonconforming Material/Component The noncompliance is that the certification label was not affixed on the product, with statement “Complies with 21 CFR 1040.10 and
1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007″.
92
2017-07-03 Class II Nonconforming Material/Component The noncompliance is that the certification label was not affixed on the product, with statement “Complies with 21 CFR 1040.10 and
1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007″.
199
2017-07-03 Class II Nonconforming Material/Component The noncompliance is that the certification label was not affixed on the product, with statement “Complies with 21 CFR 1040.10 and
1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007″.
11
2017-07-03 Class II Nonconforming Material/Component The noncompliance is that the certification label was not affixed on the product, with statement “Complies with 21 CFR 1040.10 and
1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007″.
13
2017-07-03 Class II Nonconforming Material/Component The noncompliance is that the certification label was not affixed on the product, with statement “Complies with 21 CFR 1040.10 and
1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007″.
38
2017-07-03 Class II Nonconforming Material/Component The noncompliance is that the certification label was not affixed on the product, with statement “Complies with 21 CFR 1040.10 and
1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007″.
6
2017-07-03 Class II Nonconforming Material/Component The noncompliance is that the certification label was not affixed on the product, with statement “Complies with 21 CFR 1040.10 and
1040.11 except for deviations pursuant to Laser Notice No. 50, dated June 24, 2007″.
7

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer