Vbeam Delivery System Assembly, Japan

Catalogue number 0800-00-1095, listed by Candela Corporation, United States, under Powered Laser Surgical Instrument. 92 manufacturers in China are registered for this product code.

Registry build 21.09.26
92manufacturers in China registered for this device type
1catalogue number
53510(k) clearances naming this product code
5recalls on this code

Who Else Makes It

Concentrated in Beijing (28), Guangdong (21), Hebei (13). 11 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code GEX
Manufacturer City Province Registered as Device types
Jabil Circuit (Shanghai) Ltd. Shanghai Shanghai Contract manufacturer 31
Sanbor Medical Xiamen, Inc. Xiamen Fujian Contract manufacturer 16
Beijing Winkonlaser Technology Limited Beijing Beijing Contract manufacturer 14
Changsha Gomecy Electronics Co., Ltd. Changsha Hunan Contract manufacturer 9
Gymmax Technology Shenzhen Co., Ltd. Shenzhen Guangdong Contract manufacturer 8
Guangzhou Niansheng Beauty Equipment Co., Ltd. Guangzhou Guangdong Contract manufacturer 7
Beijing Syntech Laser Co., Ltd. Beijing Beijing Contract manufacturer 5
VTech Communications Ltd Dongguan Guangdong Contract manufacturer 5
Wuhan Dimed Laser Technology Co., Ltd. Wuhan Hubei Contract manufacturer 3
Chengdu Vantron Technology Co., Ltd. Chengdu Sichuan Contract manufacturer 1
Shanghai Shengguang Science & Technology Co., Ltd. Shanghai Shanghai Contract manufacturer 1
Guilin Woodpecker Medical Instrument Co., Ltd. Guilin Guangxi Manufacturer 25

Showing 12 of 92. All 92 manufacturers in China registered for Powered Laser Surgical Instrument

Record

Regulatory record for Vbeam Delivery System Assembly, Japan
Listed by Candela Corporation, United States
FDA product code GEX
Device type Powered Laser Surgical Instrument
Device class Class 2
Regulation 21 CFR 878.4810
Establishment Specification developer, Complaint-file establishment, Manufacturer
510(k) K230990
Record published 2016-09-23
Record revised 2024-05-17 (version 9)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Distribution end date 2024-05-16

Catalogue Numbers

Catalogue numbers for Vbeam Delivery System Assembly, Japan
Catalogue number Size Status
0800-00-1095 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Accu-Beam Transamerican Technologies International 181
Powered Laser Surgical Instrument Weinert Fiber Optics Inc. 117
Waterlase Laser Tips Biolase Technology, Inc. 112
ProFlex™ Innovaquartz LLC 109
Dornier MedTech Dornier Medtech America, Inc. 91
Powered Laser Surgical Instrument Ophthalmed LLC 90
Optilite Convergent Laser Technologies 87
Reusable Surgical Optical Fiber Quanta System Spa 78
Single use Surgical Optical Fiber Quanta System Spa 70
Powered Laser Surgical Instrument Lutronic Corporation 57
Waterlase iPlus Dental Laser System Biolase Technology, Inc. 53
Leoni™ Weinert Fiber Optics Inc. 49

Showing 12 of 2,654. All products under Powered Laser Surgical Instrument

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K230990 2023-06-01
K220853 2022-10-13
K212492 2021-12-20
K201111 2020-05-26
K191685 2019-09-16
K183452 2019-02-01
K150326 2015-04-16
K140732 2014-11-07
K140122 2014-05-09
K133283 2013-12-26
K112715 2011-10-05
K111144 2011-07-18
K081324 2008-06-17
K073534 2008-04-03
K071469 2007-08-15
K063800 2007-02-05
K063074 2006-12-27
K063072 2006-12-20
K063073 2006-12-20
K051359 2005-07-13
K050673 2005-06-13
K043251 2005-02-09
K041242 2004-11-22
K033461 2004-01-16
K033331 2004-01-16
K030834 2003-12-03
K033172 2003-10-30
K030846 2003-09-16
K024371 2003-03-31
K024260 2003-03-21
K022923 2003-03-13
K024335 2003-03-12
K022951 2003-01-27
K022884 2003-01-22
K023193 2002-12-20
K014128 2002-10-04
K021180 2002-07-02
K020958 2002-06-21
K013825 2002-02-15
K013748 2002-02-11
K013043 2001-10-11
K011092 2001-07-09
K010104 2001-04-11
K002421 2000-11-03
K001093 2000-09-19
K001589 2000-08-18
K994260 2000-05-26
K993671 2000-01-24
K984601 1999-02-04
K981351 1998-07-13
K974381 1998-02-10
K972767 1997-12-04
K861179 1986-11-20

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-09-10 Class II Other The canister neck bushing may become loose and separate from the body of the canister during use. The issue occurs only when the canisters are used in Candela legacy devices that utilize screw-in or threaded interface type DCD modules in total 7,560 canisters (3240 additional as of 2/5/20) 2020-10-20
2019-09-10 Class II Other The canister neck bushing may become loose and separate from the body of the canister during use. The issue occurs only when the canisters are used in Candela legacy devices that utilize screw-in or threaded interface type DCD modules in total 7,560 canisters (3240 additional as of 2/5/20) 2020-10-20
2019-09-10 Class II Other The canister neck bushing may become loose and separate from the body of the canister during use. The issue occurs only when the canisters are used in Candela legacy devices that utilize screw-in or threaded interface type DCD modules 386 cases ( 15 pack canister/ case) (216 additional cases as 2020-10-20
2019-09-10 Class II Other The canister neck bushing may become loose and separate from the body of the canister during use. The issue occurs only when the canisters are used in Candela legacy devices that utilize screw-in or threaded interface type DCD modules in total 7,560 canisters (3240 additional as of 2/5/20) 2020-10-20
2013-11-06 Class II Software design Unintended single pulse maybe emitted to handpiece prior to pressing of trigger or footswitch and cause injury. 1258 units 2015-06-08

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer