Safeline®
NF1500M3HP Univ IV Admin. SET 118
Who Else Makes It
Concentrated in Jiangsu (18), Zhejiang (9), Guangdong (3). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Conod Medical Co., Limited | Changshu | Jiangsu | Contract manufacturer | 48 |
| Principle & Will Biotech (Pinghu) Co., Ltd. | Pinghu | Zhejiang | Contract manufacturer | 39 |
| Ningbo Luke Medical Devices Co., Ltd. | Yuyao | Zhejiang | Contract manufacturer | 27 |
| Conod Medical Shuyang Co., Ltd. | Shuyang | Jiangsu | Contract manufacturer | 22 |
| Changzhou DSB Medical Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 16 |
| Alleva Medical (D.G.) Ltd | Dongguan | Guangdong | Contract manufacturer | 13 |
| Boen Healthcare Co., Ltd. | Suzhou | Jiangsu | Specification developer | 263 |
| Jiangsu NEW Pentastar Medical Products Co., Ltd. | Changzhou | Jiangsu | Exporter | 146 |
| Huzhou Junda Industry Co., Ltd. | Anji | Zhejiang | Contract manufacturer | 129 |
| GRI Medical & Electronic Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 71 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
| Guangzhou Nuoning Medical Supplies Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 62 |
Showing 12 of 33. All 33 manufacturers in China registered for Accessories, Catheter
Record
| Listed by | B. Braun Medical Inc., United States |
|---|---|
| FDA product code | KGZ |
| Device type | Accessories, Catheter |
| Device class | Class 1 |
| Regulation | 21 CFR 878.4200 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| Record published | 2016-09-23 |
| Record revised | 2020-07-07 (version 5) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Distribution end date | 2020-06-01 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 490021 | 24 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| MedDrain | Armm, Inc. | 77 |
| Silicone Drainage Tube | Fortune Medical Instrument Corp. | 74 |
| Typenex Wound Drainage | Typenex Medical, LLC | 56 |
| Cook | Cook Incorporated | 49 |
| Marina Medical | Marina Medical Instruments, Inc. | 48 |
| Curaplex | Bound Tree Medical, LLC | 36 |
| Mediplus | Mediplus Ltd. | 29 |
| AlliedSil™ Silicone Tubing | Implantech Associates, Inc. | 24 |
| Arrow | Teleflex Medical LLC | 23 |
| Silicone Thoracic Catheters | Atrium Medical Corporation | 21 |
| Neff | Cook Incorporated | 18 |
| Silhouette | Cook Incorporated | 16 |
Showing 12 of 111. All products under Accessories, Catheter
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2025-10-29 | Class II | Process control | Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). | 15,250 units |
| 2025-10-29 | Class II | Process control | Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). | 63,192 units |
| 2025-10-29 | Class II | Process control | Potential for backflow of medication from secondary (piggyback) IV containers into primary IV containers and the inability to prime (occlusion). | 12,200 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.