T-180 Derm Drape Fenestrated
Drape Derm 1PLY 48X72 Misty - W/1 PLY & 11"FENESTRATED(SR 10690)
Who Else Makes It
Concentrated in Jiangsu (14), Zhejiang (6), Guangdong (6). 21 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| GRI Medical & Electronic Technology Co., Ltd. | Jiaxing | Zhejiang | Contract manufacturer | 71 |
| Suzhou Meccan Import and Export Corp. | Suzhou | Jiangsu | Contract manufacturer | 71 |
| Principle & Will Biotech (Pinghu) Co., Ltd. | Pinghu | Zhejiang | Contract manufacturer | 39 |
| Dongguan Shin YI Healthcare Products Factory | Dong Guan | Guangdong | Contract manufacturer | 30 |
| Exact Medical Manufacturing, Inc. | Changzhou | Jiangsu | Contract manufacturer | 17 |
| Jiangsu Likang Medical Products Co., Ltd. | Wujiang | Jiangsu | Contract manufacturer | 17 |
| Changzhou Holymed Products Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 16 |
| Xiantao Daoqi Plastic Co., Ltd. | Xiantao | Hubei | Contract manufacturer | 16 |
| Heyuan Hong DE Medical Products Co., Ltd. | Heyuan | Guangdong | Contract manufacturer | 13 |
| Wuhan Huaxin Nonwoven Co., Ltd. | Wuhan | Hubei | Contract manufacturer | 13 |
| Foshan Nanhai Plus Medical Co Ltd | Foshan | Guangdong | Contract manufacturer | 12 |
| Kunshan Jiehong Nonwoven Product Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 12 |
Showing 12 of 39. All 39 manufacturers in China registered for Drape, Surgical, Antimicrobial
Record
| Listed by | Standard Textile Co., Inc., United States |
|---|---|
| FDA product code | KKX |
| Device type | Drape, Surgical, Antimicrobial |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4370 |
| Establishment | Specification developer, Repacker / relabeller, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2018-01-29 |
| Record revised | 2023-07-06 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Over the counter | Yes |
| Label carries | lot or batch number |
| Distribution end date | 2018-01-29 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 95889482 | 72 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Microtek | Microtek Medical LLC | 994 |
| Exact Medical Manufacturing, Inc. | Exact Medical Manufacturing, Inc. | 819 |
| Halyard | O&M Halyard, Inc. | 800 |
| Medline | Medline Industries, Inc. | 517 |
| Convertors | Cardinal Health 200, LLC | 392 |
| Medline Industries, Inc. | Medline Industries, Inc. | 274 |
| TIDIShield | Tidi Products, LLC | 187 |
| DeRoyal | Deroyal Industries, Inc. | 118 |
| Cardinal Health | Cardinal Health 200, LLC | 111 |
| Angiosystems Drape | Angiosystems, Inc. | 109 |
| ComPel Surgical Drape | Standard Textile Co., Inc. | 101 |
| Drape, Surgical, Antimicrobial | Welmed, Inc. | 95 |
Showing 12 of 329. All products under Drape, Surgical, Antimicrobial
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K012807 | 2001-10-11 |
| K980183 | 1998-02-26 |
| K944863 | 1995-02-28 |
| K923811 | 1993-02-23 |
| K860447 | 1986-02-19 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.