RenovaRP

The Laborie RenovaRP® Centesis Kit is intended to be used in conjunction with the RenovaRP Pump, the RenovaRP Tube Set and the RenovaRP Fluid Drainage Bags to remove ascitic fluid from the…

Registry build 21.09.26

The Laborie RenovaRP® Centesis Kit is intended to be used in conjunction with the RenovaRP Pump, the RenovaRP Tube Set and the RenovaRP Fluid Drainage Bags to remove ascitic fluid from the abdominal cavity for paracentesis, and remove pleural effusion from the thoracic cavity for thoracentesis. The RenovaRP Centesis Kit is intended to be used by medically trained healthcare professionals knowledgeable about paracentesis and thoracentesis.

24manufacturers in China registered for this device type
4catalogue numbers in this listing
1510(k) clearance
1recall

Who Else Makes It

Concentrated in Jiangsu (11), Anhui (6), Zhejiang (4). 9 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LRO
Manufacturer City Province Registered as Device types
Conod Medical Co., Limited Changshu Jiangsu Contract manufacturer 48
Principle & Will Biotech (Pinghu) Co., Ltd. Pinghu Zhejiang Contract manufacturer 39
Sino Protection (Hefei) Medical Products Co., Ltd. Hefei Anhui Contract manufacturer 18
Changzhou Holymed Products Co., Ltd. Changzhou Jiangsu Contract manufacturer 16
Donghai Xingchen NON-Woven Products Co., Ltd. North Donghai Development Zone, Lianyungang Jiangsu Contract manufacturer 7
Fengyang Jiehong Nonwoven Product Co., Ltd. Chuzhou Anhui Contract manufacturer 7
3A Medical Products Co., Ltd. Liu An Anhui Contract manufacturer 6
Cobes Industries (Jinzhai) Co., Ltd. Luan Anhui Contract manufacturer 6
Lianyungang Aiyeh Non-woven Products Co., Ltd. Lianyungang Jiangsu Contract manufacturer 6
Jiangsu NEW Pentastar Medical Products Co., Ltd. Changzhou Jiangsu Exporter 146
Ningbo Greetmed Medical Instruments Co., Ltd. Ningbo Zhejiang Specification developer 75
GRI Medical & Electronic Technology Co., Ltd. Jiaxing Zhejiang Contract manufacturer 71

Showing 12 of 24. All 24 manufacturers in China registered for General Surgery Tray

Record

Regulatory record for RenovaRP
Listed by GI Supply, United States
FDA product code LRO
Device type General Surgery Tray
Device class Class 2
Regulation 21 CFR 878.4370
Establishment Specification developer, Complaint-file establishment, Manufacturer
Premarket notification Exempt
Record published 2021-07-08
Record revised 2024-01-15 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Contains natural rubber latex
Label carries lot or batch number, expiry date, manufacturing date
Storage Storage environment temperature 15 to 30 °C
Packaging Kit of 5, box of 20 of 20, box of 5

Catalogue Numbers

Catalogue numbers for RenovaRP
Catalogue number Size Status
GIS-31 In distribution
GIS-29 In distribution
GIS-32 In distribution
GIS-30 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Cardinal Health Cardinal Health 200, LLC 67,931
Medline Industries, Inc. Medline Industries, Inc. 54,362
Avid TruCustom Avid Medical, Inc. 13,498
Halyard Avid Medical, Inc. 12,802
ACS American Contract Systems, Inc. 10,337
SurgiTrack Owens & Minor Distribution, Inc. 5,575
Aligned Medical Solutions Aligned Medical Solutions 3,490
SurgiTrackSM Owens & Minor Distribution, Inc. 3,364
DeRoyal Deroyal Industries, Inc. 2,770
Medline Medline Industries, Inc. 1,960
Henry Schein Henry Schein, Inc. 729
Stradis Stradis Healthcare 685

Showing 12 of 113. All products under General Surgery Tray

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K970187 1997-02-14

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2016-01-28 Class II Nonconforming Material/Component Customers have reported that the pinch clamp on the RP Bag was missing. Ascetic fluid from the abdominal cavity may splash User if bag is not clamped prior to removal. 390 Kits 2016-12-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer