Invia Foam Dressing Kit
The Invia Foam Dressing Kit with FitPad is the dressing-side component set for Invia Motion and Invia Liberty negative-pressure wound therapy systems. Each kit combines foam, a FitPad…
The Invia Foam Dressing Kit with FitPad is the dressing-side component set for Invia Motion and Invia Liberty negative-pressure wound therapy systems. Each kit combines foam, a FitPad suction interface and transparent adhesive film.
The foam is a flexible, reticulated, polyether-based polyurethane material with hydrophobic properties. FitPad connects the dressing to the system’s canister tubing through a quick-connect interface, carrying the suction connection between the dressing and therapy unit.
Listed Item
Invia Foam Dressing Kit with Fitpad – Medium Sales number: 087.6222 3 PCs / 087.6226 15 pcs
Kit Options and Supply
Four foam-kit sizes are available, with one or more film pieces depending on kit size. The filed medium kit is one configuration. Components are packaged sterile for single use. These foam kits are intended specifically for the compatible Invia Motion and Invia Liberty therapy units.
Who Else Makes It
Concentrated in Jiangsu (4), Zhejiang (2), Guangdong (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Forefront Medical Technology (Jiangsu) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 14 |
| Alleva Medical (D.G.) Ltd | Dongguan | Guangdong | Contract manufacturer | 13 |
| Shanghai ISO Medical Products Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 8 |
| Zhejiang Longterm Medical Technology Co., Ltd. | Huzhou | Zhejiang | Contract manufacturer | 26 |
| VR Medical Technology Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 13 |
| Devon Medical Products (Jiangsu) Ltd | Nantong | Jiangsu | Repacker / relabeller | 12 |
| Nantong MedTech Medical Products Co., Ltd. | Nantong | Jiangsu | Contract manufacturer | 6 |
| Lightstone Medical Products (Ningbo) Co Ltd | Ningbo | Zhejiang | Specification developer | 3 |
Record
| Listed by | Medela LLC, United States |
|---|---|
| FDA product code | OMP |
| Device type | Negative Pressure Wound Therapy Powered Suction Pump |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4780 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K170088 |
| Record published | 2017-06-07 |
| Record revised | 2025-09-18 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Packaging | Pack of 3, pack of 15 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 200.8906 | In distribution | |
| 200.8905 | In distribution | |
| 200.8907 | In distribution | |
| 200.8908 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Cardinal Health | Cardinal Health 200, LLC | 57 |
| Pico | Smith & Nephew, Inc. | 57 |
| Negative Pressure Wound Therapy Powered Suction Pump | Carilex Medical, Inc. | 43 |
| DeRoyal | Deroyal Industries, Inc. | 34 |
| extriCARE | Oakwell Distribution, Inc. | 32 |
| Renasys | Smith & Nephew, Inc. | 27 |
| MicroDoc Npwt System | Pensar Medical | 26 |
| ExtriCARE | Alleva Medical Ltd | 22 |
| Vcare Alpha | I.V.T. Medical Ltd | 19 |
| V.A.C.® Granufoam™ | KCI USA, Inc. | 19 |
| Avance | Mölnlycke Health Care AB | 18 |
| Avance® Solo | Mölnlycke Health Care AB | 17 |
Showing 12 of 284. All products under Negative Pressure Wound Therapy Powered Suction Pump
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K223388 | 2023-07-07 |
| K214112 | 2022-07-26 |
| K182191 | 2019-02-01 |
| K180415 | 2018-11-02 |
| K172145 | 2018-05-09 |
| K170088 | 2017-04-06 |
| K161128 | 2016-12-01 |
| K151261 | 2015-10-07 |
| K142626 | 2015-06-12 |
| K141926 | 2014-12-19 |
| K113678 | 2012-10-01 |
| K080357 | 2008-07-24 |
| K061435 | 2006-06-08 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Medela LLC | 510(k) number | 2019-12-02 | Class II | Packaging | Invia Foam Dressing Kit with FitPad could have holes in the sterile packaging. | 331 | 2020-11-02 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2018-02-07 | Class II | Device Design | Device may display a battery missing error. | 778 units | 2018-12-04 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.