V.A.C.® Granufoam™ Silver™

Vac Granufoam Silver Dressing Medium Featuring Sensatrac Technology

Registry build 21.09.26
8manufacturers in China registered for this device type
3catalogue numbers in this listing
26510(k) clearances naming this product code
17recalls on this code

Who Else Makes It

Concentrated in Jiangsu (4), Zhejiang (2), Guangdong (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code OMP
Manufacturer City Province Registered as Device types
Forefront Medical Technology (Jiangsu) Co., Ltd. Changzhou Jiangsu Contract manufacturer 14
Alleva Medical (D.G.) Ltd Dongguan Guangdong Contract manufacturer 13
Shanghai ISO Medical Products Co., Ltd. Shanghai Shanghai Contract manufacturer 8
Zhejiang Longterm Medical Technology Co., Ltd. Huzhou Zhejiang Contract manufacturer 26
VR Medical Technology Co., Ltd. Kunshan Jiangsu Contract manufacturer 13
Devon Medical Products (Jiangsu) Ltd Nantong Jiangsu Repacker / relabeller 12
Nantong MedTech Medical Products Co., Ltd. Nantong Jiangsu Contract manufacturer 6
Lightstone Medical Products (Ningbo) Co Ltd Ningbo Zhejiang Specification developer 3

Record

Regulatory record for V.A.C.® Granufoam™ Silver™
Listed by KCI USA, Inc., United States
FDA product code OMP
Device type Negative Pressure Wound Therapy Powered Suction Pump
Device class Class 2
Regulation 21 CFR 878.4780
Establishment Specification developer, Complaint-file establishment, Manufacturer
Record published 2016-09-05
Record revised 2020-09-09 (version 4)

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Packaging 5 pack of 5, 10 pack of 10

Catalogue Numbers

Catalogue numbers for V.A.C.® Granufoam™ Silver™
Catalogue number Size Status
M8275096/5 M8275096/10 In distribution
M8275098/5 M8275098/10 In distribution
M8275099/5 M8275099/10 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Cardinal Health Cardinal Health 200, LLC 57
Pico Smith & Nephew, Inc. 57
Negative Pressure Wound Therapy Powered Suction Pump Carilex Medical, Inc. 43
DeRoyal Deroyal Industries, Inc. 34
extriCARE Oakwell Distribution, Inc. 32
Renasys Smith & Nephew, Inc. 27
MicroDoc Npwt System Pensar Medical 26
ExtriCARE Alleva Medical Ltd 22
Vcare Alpha I.V.T. Medical Ltd 19
V.A.C.® Granufoam™ KCI USA, Inc. 19
Avance Mölnlycke Health Care AB 18
Avance® Solo Mölnlycke Health Care AB 17

Showing 12 of 284. All products under Negative Pressure Wound Therapy Powered Suction Pump

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K241134 2024-05-23
K201571 2020-07-08
K200390 2020-05-18
K190697 2019-11-22
K181505 2019-03-28
K183543 2019-03-20
K181507 2019-02-15
K180855 2018-06-01
K173426 2018-03-09
K173447 2018-03-02
K160487 2016-12-09
K153199 2016-02-29
K150006 2015-11-06
K133276 2013-11-19
K132741 2013-11-15
K123507 2013-04-04
K120033 2012-05-31
K111280 2011-07-21
K100821 2010-06-11
K091585 2009-12-29
K083357 2009-03-04
K063740 2007-06-07
K063692 2007-06-07
K063590 2007-01-25
K063426 2006-12-13
K053627 2006-02-06

Recalls

14 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2025-01-17 Class II Device Design Due to increase in complaints related to leak alarms 2,169
2024-11-05 Class II Use error Due to potential system error alarm and the inability to initiate therapy as a result of broken occlusion sensors. 83,721 devices
2020-06-08 Class II Under Investigation by firm The device may power off without notification to the user resulting in a stoppage of negative pressure wound therapy. 5,823 units 2023-02-07
2017-04-28 Class II Packaging process control Potential sterile barrier breach 5,385 cases 2018-02-01
2015-11-25 Class II Package design/selection There is potential for small holes, the size of a pin, to develop in the pouches of the ActiV.A.C. Sterile Canisters. 12,728 units 2016-11-17
2014-09-18 Class II Error in labeling A portion of the V.A.C. GranuFoam Silver Dressing M8275099/10 lot 50775977 was incorrectly manufactured with an incorrect expiry date on the sterile pouch. The correct expiry date of 2015-11 is on the case label, however the pouch label id 1090 pouches (109 boxes) 2015-07-24
2014-01-30 Class II Nonconforming Material/Component Prevena Incisional Management System Kit/Dressing Connector – the male connector on the tubing is difficult to connect to the female connector on the Prevena canister tubing 20,850 units total 2015-04-06
2014-01-30 Class II Nonconforming Material/Component Prevena Incisional Management System Kit/Dressing Connector – the male connector on the tubing is difficult to connect to the female connector on the Prevena canister tubing 20,850 units total 2015-04-06
2014-01-30 Class II Nonconforming Material/Component Prevena Incisional Management System Kit/Dressing Connector – the male connector on the tubing is difficult to connect to the female connector on the Prevena canister tubing 20,850 units total 2015-04-06
2014-01-30 Class II Nonconforming Material/Component Prevena Incisional Management System Kit/Dressing Connector – the male connector on the tubing is difficult to connect to the female connector on the Prevena canister tubing 20,850 units total 2015-04-06
2014-01-30 Class II Nonconforming Material/Component Prevena Incisional Management System Kit/Dressing Connector – the male connector on the tubing is difficult to connect to the female connector on the Prevena canister tubing 20,850 units total 2015-04-06
2014-01-30 Class II Nonconforming Material/Component Prevena Incisional Management System Kit/Dressing Connector – the male connector on the tubing is difficult to connect to the female connector on the Prevena canister tubing 20,850 units total 2015-04-06
2014-01-30 Class II Nonconforming Material/Component Prevena Incisional Management System Kit/Dressing Connector – the male connector on the tubing is difficult to connect to the female connector on the Prevena canister tubing 20,850 units total 2015-04-06
2014-01-30 Class II Nonconforming Material/Component Prevena Incisional Management System Kit/Dressing Connector – the male connector on the tubing is difficult to connect to the female connector on the Prevena canister tubing 20,850 units total 2015-04-06
2009-11-04 Not classified Nonconforming Material/Component Power cords may crack and fail inside plug with potential for fire hazard. 24,640 2011-01-21
2009-11-04 Not classified Nonconforming Material/Component Power cords may crack and fail inside plug with potential for fire hazard. 649 2011-01-21
2009-11-04 Not classified Nonconforming Material/Component Power cords may crack and fail inside plug with potential for fire hazard. 37,437 2011-01-21

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer