Covidien™
Intraoperative Probe Cover, 14 cm x 244 cm (6 in x 96 in)
Who Else Makes It
Concentrated in Jiangsu (28), Guangdong (17), Hubei (14). 43 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Allmed Medical Products Co., Ltd. | Zhijiang | Hubei | Contract manufacturer | 43 |
| Principle & Will Biotech (Pinghu) Co., Ltd. | Pinghu | Zhejiang | Contract manufacturer | 39 |
| BH Medical Products Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 37 |
| Henan Yadu Industrial Co., Ltd. | Changyuan | Henan | Contract manufacturer | 35 |
| Jiangsu JianYu Health Medical Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 35 |
| Jiangsu Guangda Medical Material Group Co., Ltd. | Haian | Jiangsu | Contract manufacturer | 32 |
| Yadu Medical (Henan) Co., Ltd. | Changyuan | Henan | Contract manufacturer | 30 |
| Jingmen Huasheng Asia Dynamics Sanitary Products Co., Ltd. | Jingmen | Hubei | Contract manufacturer | 23 |
| Suzhou Jinsheng Plastic Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 23 |
| Sino Protection (Hefei) Medical Products Co., Ltd. | Hefei | Anhui | Contract manufacturer | 18 |
| Exact Medical Manufacturing, Inc. | Changzhou | Jiangsu | Contract manufacturer | 17 |
| Jiangsu Likang Medical Products Co., Ltd. | Wujiang | Jiangsu | Contract manufacturer | 17 |
Showing 12 of 107. All 107 manufacturers in China registered for Drape, Surgical, Exempt
Record
| Listed by | Microtek Medical LLC, United States |
|---|---|
| FDA product code | PUI |
| Device type | Drape, Surgical, Exempt |
| Device class | Class 2 |
| Regulation | 21 CFR 878.4370 |
| Establishment | Contract manufacturer, Specification developer, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2026-01-27 |
| Record revised | 2025-02-05 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Ethylene Oxide |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date |
| Packaging | Pack of 20, case |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Probe Covers | In distribution | |
| PC-6X96 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Convertors | Cardinal Health 200, LLC | 1,573 |
| Halyard | O&M Halyard, Inc. | 826 |
| Medline-Microtek | Microtek Medical LLC | 512 |
| Alleset | GRI Medical & Electronic Technology Co., Ltd. | 493 |
| Invenio | GRI Medical & Electronic Technology Co., Ltd. | 434 |
| Medline | Medline Industries, Inc. | 368 |
| Cardinal Health | Cardinal Health 200, LLC | 241 |
| Beaver Visitec Inter | GRI Medical & Electronic Technology Co., Ltd. | 179 |
| Steri-Drape™ | 3M Company | 177 |
| Halyard | Owens & Minor Distribution, Inc. | 136 |
| Microtek | Microtek Medical LLC | 101 |
| Medline Industries, Inc. | Medline Industries, Inc. | 87 |
Showing 12 of 305. All products under Drape, Surgical, Exempt
Recalls
8 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2025-04-13 | Class II | Labeling Change Control | Due to non-sterile products being labeled as sterile | 2,024 boxes | |
| 2023-06-23 | Class II | Under Investigation by firm | Certain lots of the products have a Naphthalene odor. | 9,293 cases/68,070 units for all products | |
| 2022-04-08 | Class II | Under Investigation by firm | Latex content in product was labeled incorrectly as latex free. | 12 cases (120 drapes) | 2024-06-05 |
| 2021-01-11 | Class II | Process control | Slits were identified in a low quantity of ORS-320 Slush + Warmer Disc Drapes from a single lot. A source for potential manufacturing error was identified and investigation is underway to prevent further recurrence. The slits may lead to a | 132 cases (3168 drapes) | 2023-01-09 |
| 2018-09-14 | Class II | Under Investigation by firm | The pouches of certain lots of product may have wrinkles along the pouch seal that could result in a channel within the seal. Should there be a channel in the pouch seal it may result in a breach in the sterility of the product. | 9,364 cases (46,820 eaches) | 2021-02-12 |
| 2018-09-14 | Class II | Under Investigation by firm | The pouches of certain lots of product may have wrinkles along the pouch seal that could result in a channel within the seal. Should there be a channel in the pouch seal it may result in a breach in the sterility of the product. | 344 cases (6,880 eaches) | 2021-02-12 |
| 2018-09-14 | Class II | Under Investigation by firm | The pouches of certain lots of product may have wrinkles along the pouch seal that could result in a channel within the seal. Should there be a channel in the pouch seal it may result in a breach in the sterility of the product. | 88 cases (1,760 eaches) | 2021-02-12 |
| 2018-09-14 | Class II | Under Investigation by firm | The pouches of certain lots of product may have wrinkles along the pouch seal that could result in a channel within the seal. Should there be a channel in the pouch seal it may result in a breach in the sterility of the product. | 4,861 cases (24,305 eaches) | 2021-02-12 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.