Ellacor

12 pack Consumable Kit (Triple Needle Cartridge,V2) includes the following items: Needle Cartridge (EL-03N02) Biofilter Suction Tube Cleaning Cover (EL-CCV01) Tube Clip (EL-CLP01)

Registry build 21.09.26
10manufacturers in China registered for this device type
25catalogue numbers in this listing
2510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Beijing (4), Guangdong (4), Hebei (2). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code QAI
Manufacturer City Province Registered as Device types
PAN-International Precision Electronic Co., Ltd. Dongguan Guangdong Contract manufacturer 4
Beijing Spiritlaser Science & Technology Co., Ltd. Beijing Beijing Contract manufacturer 21
Beijing Winkonlaser Technology Limited Beijing Beijing Contract manufacturer 14
Dongguan King Medical Technology Co., Ltd. Dongguan Guangdong Contract manufacturer 14
Beijing Beautemax Technology Limited Beijing Beijing Contract manufacturer 13
Beijing Perfectlaser Technology Co., Ltd. Beijing Beijing Manufacturer 12
Hebei Lufen Tech Co., Limited Xingtai Hebei Contract manufacturer 12
Sanhe Jumei Technology Co., Ltd. Sanhe Hebei Manufacturer 12
Guangzhou Ekai Electronic Technology Co., Ltd. Guangzhou Guangdong Contract manufacturer 1
Guangdong Carain Beauty Equipment Co., Ltd. Foshan Guangdong Contract manufacturer 1

Record

Regulatory record for ellacor
Listed by Cytrellis Biosystems, Inc., United States
FDA product code QAI
Device type Powered Microneedle Device
Device class Class 2
Regulation 21 CFR 878.4430
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K202517
Record published 2024-01-03
Record revised 2025-03-27 (version 5)

Specifications

Specifications
MRI safety MR Unsafe
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date, manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for ellacor
Catalogue number Size Per pack Status
EL-CON02 In distribution
EL-SYS02 In distribution
EL-FTS01 In distribution
EL-KIT03 In distribution
EL-03N02 In distribution
EL-FTS01-R In distribution
EL-CON02-R In distribution
EL-CON01 In distribution
EL-KIT01 In distribution
EL-HPC02-R In distribution
EL-03N01 In distribution
EL-KIT02 In distribution
EL-KIT04 In distribution
EL-03N01 2 In distribution
EL-SYS02-R In distribution
EL-03N02 2 In distribution
EL-CLP01 6 In distribution
EL-03N02 In distribution
EL-CCV01 2 In distribution
EL-HPC01-R In distribution
EL-CCV01 6 In distribution
EL-CON01-R In distribution
EL-HPC01 In distribution
EL-HPC02 In distribution
EL-SYS01 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Collagen P.I.N. Induction Therapies, LLC 9
Footswitch Mt.derm GmbH 5
SkinPen Precision Elite Bellus Medical, LLC 4
Exceed Mt.derm GmbH 4
Safety Needle Cartridge 6-MNP 1.5 Exceed US Mt.derm GmbH 3
SkinPen Precision Treatment Kits Bellus Medical, LLC 3
CytoPen S2 Emage Medical, LLC 3
Dp4 Equipmed USA B.V. 3
PRO Pen Microneedling System Dermalogica, LLC 1
Xcellarispro Twist Control unit Dermaroller GmbH 1
Eclipse EVO Microneedling Cartridge Eclipse, Inc. 1
Eclipse MicroPen EVO Eclipse, Inc. 1

Showing 12 of 43. All products under Powered Microneedle Device

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252752 2025-10-30
K202517 2021-07-09

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of ellacor
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Cytrellis Biosystems, Inc. 510(k) number 2023-06-23 Class II Process control Potential failure of a bearing adhesive joint that can occur due to an assembly issue of the X/Y stage of the handpiece. If a broken glue bond were to occur, it could cause an overlap of cores, potentially leading to prolonged healing and i 127 systems
Cytrellis Biosystems, Inc. 510(k) number 2023-04-07 Class II Use error Irregular core patterns could cause potential overlap of cores at the 8% setting, potentially leading to prolonged healing, irregularities in patient skin texture post-treatment, and/or scarring. 89 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer