Neptune
Docking Station with Detergent Dispenser 100-230 V 50-60Hz 3A
Who Else Makes It
Concentrated in Zhejiang (1), Shandong (1), Guangdong (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Shuyou Surgical Instrument Co., Ltd. | Huzhou | Zhejiang | Contract manufacturer | 13 |
| BIO Protech Yantai Inc | Yantai | Shandong | Manufacturer | 12 |
| Wickimed (Huizhou) Medical Equipment Manufacturing Co., Ltd. | Huizhou | Guangdong | Contract manufacturer | 3 |
Record
| Listed by | Stryker GmbH, Switzerland |
|---|---|
| FDA product code | FYD |
| Device type | Apparatus, Exhaust, Surgical |
| Device class | Class 2 |
| Regulation | 21 CFR 878.5070 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| Record published | 2019-10-17 |
| Record revised | 2020-01-20 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, serial number |
| Storage | Handling environment atmospheric pressure 78 to 106 KiloPascal; Handling environment humidity 30 to 75 % RH; Handling environment temperature 10 to 35 °C |
| Packaging | Pack of 24 |
| Distribution end date | 2021-03-25 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 0703-045-002 | In distribution | |
| 0700035000 | In distribution | |
| 0702002000IT | In distribution | |
| 0703-040-000 | In distribution | |
| 0702002000KO | In distribution | |
| 0702002000FI | In distribution | |
| 0703001000 | In distribution | |
| 0703-045-000 | In distribution | |
| 0702002000NL | In distribution | |
| 0703-045-003 | In distribution | |
| 0702002000DA | In distribution | |
| 0702002000PT | In distribution | |
| 0700006000 | Withdrawn | |
| 0700005000 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Microtek | Microtek Medical LLC | 57 |
| Surgimedics® | Coastal Life Technologies, Inc. | 23 |
| Virosafe | ConMed Corporation | 22 |
| Buffalo Filter | Buffalo Filter Co., Inc. | 22 |
| ACU-Evac | Acuderm, Inc. | 21 |
| RapidVac | Covidien LP | 12 |
| Megadyne | Megadyne Medical Products, Inc. | 12 |
| Geiger Smoke Evacuator Filter | Dermatologic LAB AND Supply, Inc. | 12 |
| Apparatus, Exhaust, Surgical | Stryker GmbH | 11 |
| Apparatus, Exhaust, Surgical | ConMed Corporation | 10 |
| Conmed Buffalo Filter | ConMed Corporation | 10 |
| Steris | I.C. Medical, Inc. | 9 |
Showing 12 of 142. All products under Apparatus, Exhaust, Surgical
Recalls
4 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2015-07-20 | Class II | Nonconforming Material/Component | The Fluid Coupling Sleeve, a component within the Neptune Waste Management System Docker, may be out of specification. This can cut or dislodge the PTFE seal and cause a leak between the Rover and Docker couplers during docking or leaking f | 524, 237 of these are non-conforming | 2016-11-07 |
| 2014-03-26 | Class II | Material/Component Contamination | During packaging verification testing, a failure occurred due to cuts in the packaging potentially causing a breach in the sterile barrier. Additional testing identified microscopic aluminum metal shavings and foreign particles estimated i | 35,310 unexpired units | 2014-12-11 |
| 2012-06-08 | Class I | Labeling False and Misleading | Stryker has received two reports of serious injury as a result of tissue damage associated with the use of the Neptune 2, including an event in which one customer connected the Neptune 2 System to a passive chest drainage tube post operativ | 2657 | 2016-08-23 |
| 2012-06-08 | Class I | Labeling False and Misleading | Stryker has received two reports of serious injury as a result of tissue damage associated with the use of the Neptune 2, including an event in which one customer connected the Neptune 2 System to a passive chest drainage tube post operativ | 10,394 domestic, 276 international | 2016-08-23 |
| 2012-06-08 | Class I | Labeling False and Misleading | Stryker has received two reports of serious injury as a result of tissue damage associated with the use of the Neptune 2, including an event in which one customer connected the Neptune 2 System to a passive chest drainage tube post operativ | 1075 | 2016-08-23 |
| 2012-06-08 | Class I | Labeling False and Misleading | Stryker has received two reports of serious injury as a result of tissue damage associated with the use of the Neptune 2, including an event in which one customer connected the Neptune 2 System to a passive chest drainage tube post operativ | 5925 domestic 2 international | 2016-08-23 |
| 2004-10-12 | Not classified | Other | The grounding pin may break inside of the electrical plug, resulting in a shock hazard. | 365 | 2005-03-28 |
| 2004-10-12 | Not classified | Other | The grounding pin may break inside of the electrical plug, resulting in a shock hazard. | 1317 | 2005-03-28 |
| 2002-12-03 | Not classified | Other | Cap may be cracked and fail, exposing O.R. staff to patient blood, and cause an unexpected loud noise in the O.R. | 370 | 2003-07-07 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.