Neptune

Docking Station with Detergent Dispenser 100-230 V 50-60Hz 3A

Registry build 21.09.26
3manufacturers in China registered for this device type
14catalogue numbers in this listing
9recalls on this code

Who Else Makes It

Concentrated in Zhejiang (1), Shandong (1), Guangdong (1).

Chinese manufacturers registered for FDA product code FYD
Manufacturer City Province Registered as Device types
Zhejiang Shuyou Surgical Instrument Co., Ltd. Huzhou Zhejiang Contract manufacturer 13
BIO Protech Yantai Inc Yantai Shandong Manufacturer 12
Wickimed (Huizhou) Medical Equipment Manufacturing Co., Ltd. Huizhou Guangdong Contract manufacturer 3

Record

Regulatory record for Neptune
Listed by Stryker GmbH, Switzerland
FDA product code FYD
Device type Apparatus, Exhaust, Surgical
Device class Class 2
Regulation 21 CFR 878.5070
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer
Record published 2019-10-17
Record revised 2020-01-20 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, serial number
Storage Handling environment atmospheric pressure 78 to 106 KiloPascal; Handling environment humidity 30 to 75 % RH; Handling environment temperature 10 to 35 °C
Packaging Pack of 24
Distribution end date 2021-03-25

Catalogue Numbers

Catalogue numbers for Neptune
Catalogue number Size Status
0703-045-002 In distribution
0700035000 In distribution
0702002000IT In distribution
0703-040-000 In distribution
0702002000KO In distribution
0702002000FI In distribution
0703001000 In distribution
0703-045-000 In distribution
0702002000NL In distribution
0703-045-003 In distribution
0702002000DA In distribution
0702002000PT In distribution
0700006000 Withdrawn
0700005000 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Microtek Microtek Medical LLC 57
Surgimedics® Coastal Life Technologies, Inc. 23
Virosafe ConMed Corporation 22
Buffalo Filter Buffalo Filter Co., Inc. 22
ACU-Evac Acuderm, Inc. 21
RapidVac Covidien LP 12
Megadyne Megadyne Medical Products, Inc. 12
Geiger Smoke Evacuator Filter Dermatologic LAB AND Supply, Inc. 12
Apparatus, Exhaust, Surgical Stryker GmbH 11
Apparatus, Exhaust, Surgical ConMed Corporation 10
Conmed Buffalo Filter ConMed Corporation 10
Steris I.C. Medical, Inc. 9

Showing 12 of 142. All products under Apparatus, Exhaust, Surgical

Recalls

4 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2015-07-20 Class II Nonconforming Material/Component The Fluid Coupling Sleeve, a component within the Neptune Waste Management System Docker, may be out of specification. This can cut or dislodge the PTFE seal and cause a leak between the Rover and Docker couplers during docking or leaking f 524, 237 of these are non-conforming 2016-11-07
2014-03-26 Class II Material/Component Contamination During packaging verification testing, a failure occurred due to cuts in the packaging potentially causing a breach in the sterile barrier. Additional testing identified microscopic aluminum metal shavings and foreign particles estimated i 35,310 unexpired units 2014-12-11
2012-06-08 Class I Labeling False and Misleading Stryker has received two reports of serious injury as a result of tissue damage associated with the use of the Neptune 2, including an event in which one customer connected the Neptune 2 System to a passive chest drainage tube post operativ 2657 2016-08-23
2012-06-08 Class I Labeling False and Misleading Stryker has received two reports of serious injury as a result of tissue damage associated with the use of the Neptune 2, including an event in which one customer connected the Neptune 2 System to a passive chest drainage tube post operativ 10,394 domestic, 276 international 2016-08-23
2012-06-08 Class I Labeling False and Misleading Stryker has received two reports of serious injury as a result of tissue damage associated with the use of the Neptune 2, including an event in which one customer connected the Neptune 2 System to a passive chest drainage tube post operativ 1075 2016-08-23
2012-06-08 Class I Labeling False and Misleading Stryker has received two reports of serious injury as a result of tissue damage associated with the use of the Neptune 2, including an event in which one customer connected the Neptune 2 System to a passive chest drainage tube post operativ 5925 domestic 2 international 2016-08-23
2004-10-12 Not classified Other The grounding pin may break inside of the electrical plug, resulting in a shock hazard. 365 2005-03-28
2004-10-12 Not classified Other The grounding pin may break inside of the electrical plug, resulting in a shock hazard. 1317 2005-03-28
2002-12-03 Not classified Other Cap may be cracked and fail, exposing O.R. staff to patient blood, and cause an unexpected loud noise in the O.R. 370 2003-07-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer