Endobutton
Endobutton CL Fixation Button With 25 MM Continuous Loop Suture
Who Else Makes It
Concentrated in Shanghai (2), Shandong (2), Fujian (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Arthrex (Shanghai) Co., Ltd. | Shanghai | Shanghai | Exporter | 38 |
| Shandong Haidike Medical Products Co., Ltd. | Heze | Shandong | Manufacturer | 22 |
| Xiamen Zhiyuan Medical Technology Co., Ltd. | Xiamen | Fujian | Contract manufacturer | 22 |
| Foosin Medical Supplies Inc.ltd | Weihai | Shandong | Manufacturer | 8 |
| ARC Medical Supplies (Beijing) Co., Ltd. | Beijing | Beijing | Manufacturer | 7 |
Record
| Listed by | Smith & Nephew, Inc., United States |
|---|---|
| FDA product code | GAT |
| Device type | Suture, Nonabsorbable, Synthetic, Polyethylene |
| Device class | Class 2 |
| Regulation | 21 CFR 878.5000 |
| Establishment | Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K980155 |
| Record published | 2015-08-30 |
| Record revised | 2023-09-07 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Distribution end date | 2017-04-03 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 7210086 | In distribution | |
| 7207324 | In distribution | |
| 72200153 | In distribution | |
| 72200154 | In distribution | |
| 72200148 | In distribution | |
| 7209352 | In distribution | |
| 7210084 | In distribution | |
| 7210085 | In distribution | |
| 7210083 | In distribution | |
| 72200149 | In distribution | |
| 72200151 | In distribution | |
| 7210080 | In distribution | |
| 7209353 | Withdrawn | |
| 7207326 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Premicron | B Braun Surgical SA | 1,377 |
| Deknatel | Teleflex Medical LLC | 1,198 |
| FlexiGRAFT® | LifeNet Health | 992 |
| DemeBOND | Demetech Corp. | 939 |
| Ti-Cron | Covidien LP | 482 |
| HS FIber | Riverpoint Medical LLC | 413 |
| Ethibond Excel | Ethicon, Inc. | 383 |
| Arthrex® | Arthrex, Inc. | 307 |
| Dagrofil | B Braun Surgical SA | 195 |
| WEGO-Polyester Nonabsorbable Surgical Suture With Needle | Foosin Medical Supplies Inc.ltd | 175 |
| Cardioxyl ® | Peters Surgical | 162 |
| Silkam | B Braun Surgical SA | 150 |
Showing 12 of 275. All products under Suture, Nonabsorbable, Synthetic, Polyethylene
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K203393 | 2021-02-01 |
| K132079 | 2013-12-05 |
| K132357 | 2013-10-30 |
| K121861 | 2012-10-18 |
| K092508 | 2010-01-28 |
| K072322 | 2007-09-18 |
| K052652 | 2005-10-21 |
| K041216 | 2004-06-07 |
| K040789 | 2004-06-04 |
| K984550 | 1999-03-01 |
| K980155 | 1998-04-01 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2015-04-30 | Class II | Package design/selection | Sterility of device maybe compromised | 202,279 units | 2017-09-19 |
| 2010-10-14 | Not classified | Device Design | FasT-Fix 360 Needle Delivery System may not allow the T-2 (anchor) to advance for implantation. | 621 units | 2012-05-09 |
| 2010-10-14 | Not classified | Device Design | FasT-Fix 360 Needle Delivery System may not allow the T-2 (anchor) to advance for implantation. | 53 units | 2012-05-09 |
| 2010-10-14 | Not classified | Device Design | FasT-Fix 360 Needle Delivery System may not allow the T-2 (anchor) to advance for implantation. | 130 units | 2012-05-09 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| N16374 | 1986-01-23 | PROLENE*POLYPROPYLENE SUTURE NONABSORBABLE SURG. S | Ethicon, Inc. |
| P810028 | 1984-12-17 | DEKLENE(TM) | Deknatel, Inc. |
| N17825 | 1981-09-24 | SURGILENE | Davis & Geck, Inc. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.