STS Adapter, 5cm

Stainless Steel Adapter, for WAL Applicator Short and Biofill Cannula, 5cm

Registry build 21.09.26
2manufacturers in China registered for this device type
1catalogue number
1510(k) clearance
1recall

Who Else Makes It

Concentrated in Jiangsu (1), Zhejiang (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code QPB
Manufacturer City Province Registered as Device types
Ningbo Shun YE Medical Company, Ltd. Cixi Ningbo Zhejiang Contract manufacturer 8
Jiangsu Caina Medical Co., Ltd. Jiangyin Jiangsu Contract manufacturer 20

Record

Regulatory record for STS Adapter, 5cm
Listed by Human MED AG, Germany
FDA product code QPB
Device type System, Suction, Lipoplasty For Removal
Device class Class 2
Regulation 21 CFR 878.5040
Establishment Manufacturer
510(k) K082025
Record published 2025-07-30

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number, serial number

Catalogue Numbers

Catalogue numbers for STS Adapter, 5cm
Catalogue number Size Status
STS Adapter, for WAL Applicator Short and Biofill Cannula, L=50 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Origins Solta Medical, Inc. 164
MicroAire® Microaire Surgical Instruments LLC 156
Tulip Gems™ Single-Use Tulip Medical Products, Inc. 53
Tulip Gems™ AlphaLuer Single-Use Tulip Medical Products, Inc. 33
Vaser Solta Medical, Inc. 20
System, Suction, Lipoplasty For Removal Black & Black Surgical, Inc. 12
WAL Cannula Human MED AG 7
Biofill cannula Human MED AG 6
WAL infiltration cannula Human MED AG 5
Ayon Ultrasound Assisted Liposuction Probe: 3.7mm diameter, 33cm length, 5 rings Apyx Medical Corporation 5
WAL irrigation/aspiration cannula Human MED AG 4
Black & Black Surgical, Inc. Black & Black Surgical, Inc. 4

Showing 12 of 66. All products under System, Suction, Lipoplasty For Removal

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K082025 2008-08-13

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of STS Adapter, 5cm
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Human MED AG 510(k) number 2024-10-18 Class II Process control The cannula tubes do not comply with the specification. The water jet emerging from the nozzle of the nonconforming cannulas may emerge as a spot jet rather than a fan-shaped spray jet. 775 devices

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer