EA-36, -50, -65 and Modified EA are ready-to-use cytoplasmic counterstains used for gynecological and non-gynecological cytology specimens. These products contain common dyes and reagent solvents used in traditional EA formulations. A well-preserved or fixed slide with adequate exposure to 95% alcohol or a commercial spray fixative is highly recommended for optimal staining results. Cellular results are traditional as well, with basal or intermediate cells staining a blue-green hue and surface cells staining a pink-red hue. This multicolored effect is due to dye uptake by various cells and their affinities for the specific dyes. EA 50 is used in conjunction with OG-6 for the staining of gynecological specimens. It will provide a very traditional staining result with common staining hues and intensities. EA-50 can also be used for non-gynecological specimens however, although EA-65 is recommended.

4manufacturers in China registered for this device type
22catalogue numbers in this listing
1recall

Who Else Makes It

Concentrated in Zhejiang (2), Shandong (1), Hubei (1).

Chinese manufacturers registered for FDA product code HZJ
Manufacturer City Province Registered as Device types
Zhejiang Gene Science Co., Ltd. Shaoxing Zhejiang Manufacturer 31
Jinan Babio Biotechnology Co., Ltd. Jinan Shandong Manufacturer 25
Wuhan Landing Intelligence Medical Co., Ltd. Wuhan Hubei Manufacturer 17
Hangzhou Healthsky Biotechnology Co., Ltd. Hangzhou Zhejiang Manufacturer 6

Record

Regulatory record for Epredia
Listed by Richard-Allan Scientific LLC, United States
FDA product code HZJ
Device type Stain, Papanicolau
Device class Class 1
Regulation 21 CFR 864.1850
Establishment Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer
Premarket notification Exempt
Record published 2024-08-09

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Supplied as a kit Yes
Label carries lot or batch number, expiry date, manufacturing date
Distribution end date 2024-08-09

Catalogue Numbers

Catalogue numbers for Epredia
Catalogue number Size Status
Cyto-Stain G In distribution
EA-50 Papanicolaou Stain In distribution
Cyto-Stain ™ In distribution
Cyto-Stain ™ In distribution
EA-50 Papanicolaou Stain In distribution
EA-50 Papanicolaou Stain In distribution
EA-65 Papanicolaou Stain In distribution
EA-36 Papanicolaou Stain In distribution
Rapid Chrome™ Papanicolaou Staining Kit In distribution
EA-50 Papanicolaou Stain In distribution
EA-36 Papanicolaou Stain In distribution
Modified EA Papanicolaou Stain Withdrawn
OG-6 Papanicolaou Stain Withdrawn
Orange G-6 Papanicolaou Stain Withdrawn
EA-65 Papanicolaou Stain Withdrawn
Orange G-6 Papanicolaou Stain Withdrawn
EA-65 Papanicolaou Stain Withdrawn
EA-65 Papanicolaou Stain Withdrawn
EA-65 Papanicolaou Stain Withdrawn
Modified OG Papanicolaou Stain Withdrawn
OG-6 Papanicolaou Stain Withdrawn
OG-6 Papanicolaou Stain Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
ThinPrep Hologic, Inc. 7
Rowley Biochemical Hydrochloric Acid 0.25% Transene Company, Inc. 1
Rowley Biochemical Modified Orange G Transene Company, Inc. 1
Rowley Biochemical Scott’s Water Transene Company, Inc. 1
Rowley Biochemical EA Counterstain Transene Company, Inc. 1
Fisherbrand Fisher Scientific Company L.L.C. 1
Rowley Biochemical Orange G Transene Company, Inc. 1
Rowley Biochemical Harris Hematoxylin Transene Company, Inc. 1

Recalls

1 of these is Class III. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2015-02-19 Class III Error in labeling The case was correctly labeled as REF 7501R, however the gallon bottle was incorrectly labeled as REF 7501G Cyto-Stain G. The bottle label has the correct lot number of 313833 and EXP date 11/2016. The gallon bottle contains the correct i 132 2016-01-12

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer