Epidermal Growth Factor Receptor (Egfr)

2 catalogue numbers from ACI063CK, listed by Biocare Medical, LLC, United States, under Immunohistochemistry Reagents And Kits. 7 manufacturers in China are registered for this product code.

Registry build 21.09.26
7manufacturers in China registered for this device type
2catalogue numbers in this listing
9recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Jilin (1), Zhejiang (1).

Chinese manufacturers registered for FDA product code NJT
Manufacturer City Province Registered as Device types
Dirui Industrial Co., Ltd. Changchun Jilin Contract manufacturer 84
Zhejiang Gene Science Co., Ltd. Shaoxing Zhejiang Manufacturer 31
Shijiazhuang Hipro Biotechnology Co., Ltd. Shijiazhuang Hebei Manufacturer 22
Henan Celnovte Biotechnology Co., Ltd. Zhengzhou Henan Manufacturer 8
Shenzhen Dakewe BIO-Engineering Co., Ltd. Shenzhen Guangdong Manufacturer 7
Shenzhen Dartmon Biotechnology Co., Ltd. Shenzhen Guangdong Manufacturer 4
Fuzhou Maixin Biotech Co., Ltd. Fuzhou Fujian Manufacturer 3

Record

Regulatory record for Epidermal Growth Factor Receptor (Egfr)
Listed by Biocare Medical, LLC, United States
FDA product code NJT
Device type Immunohistochemistry Reagents And Kits
Device class Class 1
Regulation 21 CFR 864.1860
Establishment Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
Premarket notification Exempt
Record published 2022-09-23
Record revised 2023-04-26 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date
Storage Storage environment temperature 2 to 8 °C

Catalogue Numbers

Catalogue numbers for Epidermal Growth Factor Receptor (Egfr)
Catalogue number Size Status
ACI063CK In distribution
ACI063AK In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Diagnostic BioSystems Diagnostic Biosystems 2,453
Thermo Scientific Richard-Allan Scientific LLC 866
IHC Slmp, LLC 350
Tissue-Tek Genie® Sakura Finetek U.S.A., Inc. 330
Bond Leica Biosystems Newcastle Ltd 327
Novocastra Leica Biosystems Newcastle Ltd 272
Genemed® Sakura Finetek U.S.A., Inc. 167
Epredia Richard-Allan Scientific LLC 46
Prame [EPR20330] Biocare Medical, LLC 14
Cyclin D1 Biocare Medical, LLC 14
Napsin A Biocare Medical, LLC 13
Tissue-Tek Genie® DUO Sakura Finetek U.S.A., Inc. 13

Showing 12 of 3,569. All products under Immunohistochemistry Reagents And Kits

Recalls

6 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-10-10 Class II Pending Firm has identified product has no staining. If used, may result in invalid test results when used with controls in the clinical setting. Positive control would observe no staining. The clinical impact may result in the consumption of patie 8 2020-12-02
2018-04-24 Class II Material/Component Contamination Chromogen failed to develop due to a stability issue caused by environmental factors with a raw material in the Vulcan Fast Red Buffer. 43 units 2020-07-14
2018-03-15 Class II Other Immunohistochemistry device kits found to display incorrect staining pattern due to mislabeling of two components. 11 2020-04-22
2016-03-31 Class III Labeling mix-ups Biocare Medical has identified a single lot (082715) of its Mach 4 HRP Polymer kit in which some few Mach 4 Mouse Probe vials may have been mislabeled as HRP-Polymer. 93 2016-06-20
2015-09-08 Class II Device Design Certain catalog numbers and lots of Smooth Muscle Actin may stain some cell types that are typically expected to be negative for SMA. 151 units 2016-01-11
2015-05-06 Class III Labeling mix-ups Firm discovered that incorrect Instructions for Use were shipped with one lot of D2-40. 19 units 2015-06-04
2015-03-17 Class II Unknown/Undetermined by firm A drop in staining intensity over time has been observed. These lots may not meet their labeled shelf life. 44: 8 of lot 110912, 15 of lot 041913; 17 of lot 120310 and 2015-06-15
2014-12-12 Class II Incorrect or no expiration date Three lots of MUM-1 may not meet their labeled shelf life, as a drop in staining intensity over time has been observed. 59 2015-03-30
2012-03-13 Not classified Nonconforming Material/Component Reports of sporadic failure of specific lots of Vina Green Chromogen Kit, either through crystal formation that obscures positive staining, color not right, or a complete fading of staining by the chromogen. 74 kits 2012-09-20

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer