Hemoccult
Hemoccult ICT Immunochemical Fecal Occult Blood Test Controls
Who Else Makes It
Concentrated in Zhejiang (2), Guangdong (1), Beijing (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Orient Gene Biotech | Huzhou | Zhejiang | Contract manufacturer | 86 |
| Hangzhou Genesis Biodetection & Biocontrol Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 5 |
| Guangzhou Wondfo Biotech Co., Ltd. | Guangzhou | Guangdong | Contract manufacturer | 44 |
| W.h.p.m. Bioresearch & Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 37 |
| Chong Qing Teco Huayi Pharm. Co. | Shapingba Dist. | Chongqing | Contract manufacturer | 18 |
Record
| Listed by | Beckman Coulter, Inc., United States |
|---|---|
| FDA product code | KHE |
| Device type | Reagent, Occult Blood |
| Device class | Class 2 |
| Regulation | 21 CFR 864.6550 |
| Establishment | Contract manufacturer, Specification developer, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2016-09-23 |
| Record revised | 2023-06-19 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 64130 | In distribution | |
| 395068 | In distribution | |
| A96636 | In distribution | |
| 61200 | In distribution | |
| 60152 | In distribution | |
| 395261 | In distribution | |
| 395065 | In distribution | |
| 64152 | In distribution | |
| 60151 | In distribution | |
| 395066 | In distribution | |
| 64151 | In distribution | |
| 63202 | In distribution | |
| 61100 | In distribution | |
| 62115 | In distribution | |
| 61130 | In distribution | |
| 395067 | In distribution | |
| 64115 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| OC-Light S | Polymedco Cancer Diagnostic Products LLC | 59 |
| McKesson | Mckesson Medical-Surgical Inc. | 21 |
| Hemosure | Hemosure Inc. | 21 |
| Henry Schein | Henry Schein, Inc. | 14 |
| PremierPro | Prestige Ameritech | 11 |
| hema-screen Specific | Immunostics, Inc. | 9 |
| InSure® ONE™ | Enterix Inc. | 8 |
| InSure FIT | Enterix Inc. | 7 |
| hema-screen | Immunostics, Inc. | 7 |
| ADS Medical | W.h.p.m., Inc. | 7 |
| QuickVue | Quidel Corp. | 6 |
| Medline | Medline Industries, Inc. | 5 |
Showing 12 of 135. All products under Reagent, Occult Blood
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K080812 | 2008-06-25 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2013-07-17 | Class II | Under Investigation by firm | Beckman Coulter has received a customer complaint that suggests trending of positive results has increased from approximately 4% to 1 0%. As a result of our investigation, Beckman Coulter has confirmed an increase in sensitivity at the bord | 68,116 units | 2014-10-24 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.