User-Fillable Reagent Bottle 5ml Capacity (Link)

Catalogue number SK200, listed by Agilent Technologies, Inc, United States, under Slide Stainer, Automated. 14 manufacturers in China are registered for this product code.

Registry build 21.09.26
14manufacturers in China registered for this device type
1catalogue number
4recalls on this code

Who Else Makes It

Concentrated in Shanghai (2), Jiangsu (2), Shandong (2).

Chinese manufacturers registered for FDA product code KPA
Manufacturer City Province Registered as Device types
Infitek Co., Ltd. Shanghai Shanghai Manufacturer 49
Diatrust Medical Co., Ltd. Nanjing Jiangsu Manufacturer 48
Labpeak Co., Ltd. Jinan Shandong Manufacturer 43
Scitek Global Co., Ltd. Jinan Shandong Manufacturer 43
Zhejiang Gene Science Co., Ltd. Shaoxing Zhejiang Manufacturer 31
AVE Science & Technology Co., Ltd. Changsha Hunan Manufacturer 22
Wuhan Landing Intelligence Medical Co., Ltd. Wuhan Hubei Manufacturer 17
Leica Instruments (Shanghai) Co., Ltd. Shanghai Shanghai Contract manufacturer 11
Dakewe(Shenzhen) Medical Equipment Co., Ltd. Shenzhen Guangdong Repacker / relabeller 9
Henan Celnovte Biotechnology Co., Ltd. Zhengzhou Henan Manufacturer 8
Hangzhou Healthsky Biotechnology Co., Ltd. Hangzhou Zhejiang Manufacturer 6
Jiangsu Medomics Medical Technology Co., Ltd. Nanjing Jiangsu Contract manufacturer 5

Showing 12 of 14. All 14 manufacturers in China registered for Slide Stainer, Automated

Record

Regulatory record for User-Fillable Reagent Bottle 5mL Capacity (Link)
Listed by Agilent Technologies, Inc, United States
FDA product code KPA
Device type Slide Stainer, Automated
Device class Class 1
Regulation 21 CFR 864.3800
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
Premarket notification Exempt
Record published 2020-09-17
Record revised 2021-01-22 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Label carries lot or batch number, expiry date
Storage Storage environment temperature 2 to 8 °C
Packaging Box of 25
Sizes Total volume 5 ml

Catalogue Numbers

Catalogue numbers for User-Fillable Reagent Bottle 5mL Capacity (Link)
Catalogue number Size Status
SK200 Total Volume 5 ml In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Epredia Shandon Diagnostics Limited 54
Thermo Fisher Shandon Diagnostics Limited 27
Bond Leica Biosystems Melbourne PTY Ltd 21
HistoPro® Rushabh Instruments, LLC 5
intelliPATH Plus Biocare Medical, LLC 4
Alinity Abbott Laboratories 4
intelliPATH MAX Biocare Medical, LLC 4
Bond Leica Biosystems Newcastle Ltd 4
Dako Agilent Technologies, Inc 3
Advia Autoslide® Slide Maker Stainer Siemens Healthcare Diagnostics Inc 3
Bond-Prime automated stainer Leica Biosystems Melbourne PTY Ltd 2
Decloaking Chamber™ NxGen Reconditioned Biocare Medical, LLC 2

Showing 12 of 153. All products under Slide Stainer, Automated

Recalls

4 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-04-02 Class II Device Design There is the potential for the front plexiglass door of the automated slide processing system to break causing potential injury. 1160 devices
2015-04-01 Class II Other If a user requests slides from the LIS or TPID, then updates a request by changing the test, the TRD software will reject the update. The LIS and printed slide label will display the updated test with the requested change, but the Omnis sys 33 (7 in U.S. and 26 Internationally) 2015-08-05
2015-02-12 Class II Nonconforming Material/Component A false negative result affecting the diagnosis may occur. A defect in the syringe assembly stopcock component may, in some circumstances, cause leakage of excess buffer onto slide location 34 on the AS480, or slide locations 35 and 36 on t 409 2016-02-11
2014-08-29 Class II Software change control Dako is recalling the Dako Link 4.0.3 software on the Dako Autostainer Link 48 because Dako has determined that an upgrade to this version of the software may cause premature rejection of reagent bottles or inadequate aspiration of reagent 191 units total (57 units in US) 2015-03-03

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer