GEM Check Coag Control-Normal for ACT-LR
Catalogue number 06260060600, listed by Instrumentation Laboratory SPA, Italy, under Plasma, Coagulation Control. 3 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shandong (2), Shanghai (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Infitek Co., Ltd. | Shanghai | Shanghai | Manufacturer | 49 |
| Labpeak Co., Ltd. | Jinan | Shandong | Manufacturer | 43 |
| Scitek Global Co., Ltd. | Jinan | Shandong | Manufacturer | 43 |
Record
| Listed by | Instrumentation Laboratory SPA, Italy |
|---|---|
| FDA product code | GGN |
| Device type | Plasma, Coagulation Control |
| Device class | Class 2 |
| Regulation | 21 CFR 864.5425 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Record published | 2016-09-23 |
| Record revised | 2026-05-18 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 2 to 8 °C |
| Distribution end date | 2024-01-25 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 06260060600 | 15 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| George King Pooled Normal Plasma | George King BIO-Medical, Inc. | 15 |
| directCHECK Whole Blood Controls | Accriva Diagnostics, Inc. | 12 |
| Thermo Scientific Pacific Hemostasis® | Fisher Diagnostics | 8 |
| Lyphochek | Bio-Rad Laboratories Inc. | 8 |
| George King Single Donor Normal Plasma | George King BIO-Medical, Inc. | 7 |
| Validate | LGC Clinical Diagnostics, Inc. | 6 |
| George King Coumadin® Plasma | George King BIO-Medical, Inc. | 5 |
| Plasma, Coagulation Control | Medtronic, Inc. | 5 |
| Liquichek | Bio-Rad Laboratories Inc. | 5 |
| CueSee® Coag | Eurotrol B.V. | 5 |
| Rotem® | TEM Innovations GmbH | 4 |
| CRYOcheck™ Pooled Normal Plasma | Precision BioLogic Inc. | 4 |
Showing 12 of 129. All products under Plasma, Coagulation Control
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K133582 | 2014-08-15 |
| K113211 | 2012-01-04 |
| K090563 | 2009-10-09 |
| K082859 | 2008-12-19 |
| K030965 | 2003-06-06 |
| K021024 | 2002-05-16 |
| K021022 | 2002-05-14 |
| K021023 | 2002-05-14 |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. 3 are recorded with the root cause “No Marketing Application”: the device was distributed without the premarket submission its class requires, a compliance finding rather than a defect. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2013-11-15 | Class II | No Marketing Application | HemosIL Low, Abnormal, Normal Controls UNASSAYED (no-value assigned) lacks 510(k) approval | 84561 kits | 2014-03-25 |
| 2013-11-15 | Class II | No Marketing Application | HemosIL Low, Abnormal, Normal Controls UNASSAYED (no-value assigned) lacks 510(k) approval | 80319 Kits | 2014-03-25 |
| 2013-11-15 | Class II | No Marketing Application | HemosIL Low, Abnormal, Normal Controls UNASSAYED (no-value assigned) lacks 510(k) approval | 6504 kits | 2014-03-25 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.