Stat Profile

Prime Sensor Card CCS (High Volume)

Registry build 21.09.26
1manufacturer
2catalogue numbers in this listing
3510(k) clearances naming this product code

Who Else Makes It

Registered in Guangdong.

Chinese manufacturers registered for FDA product code GKF
Manufacturer City Province Registered as Device types
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56

Record

Regulatory record for Stat Profile
Listed by Nova Biomedical Corporation, United States
FDA product code GKF
Device type Instrument, Hematocrit, Automated
Device class Class 2
Regulation 21 CFR 864.5600
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K141907
Record published 2017-07-06
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date, serial number
Storage Storage environment humidity 20 to 85 % RH; Handling environment temperature 15 to 32 °C; Storage environment temperature 15 to 32 °C; Special storage condition: Without Condensation; Special storage condition: 0 ft to 12000 ft
Packaging Box, carton

Catalogue Numbers

Catalogue numbers for Stat Profile
Catalogue number Size Status
PRIME CCS In distribution
PRIME CCS In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
RAPIDPOINT®340/350 pH Electrode Siemens Healthcare Diagnostics Inc 1
RAPIDPoint® 400 Measurement Cartridge Siemens Healthcare Diagnostics Inc 1
UltraChek Reference Controls Low Separation Technology, Inc. 1
Rapidpoint® 340/350 Valve Module Siemens Healthcare Diagnostics Inc 1
UltraCrit (Refurbished) Separation Technology, Inc. 1
UltraCrit Cuvettes Separation Technology, Inc. 1
RAPIDSystems™ AutomaticQC Cartridge Siemens Healthcare Diagnostics Inc 1
UltraChek Reference Controls High Separation Technology, Inc. 1
UltraCrit Loaner Separation Technology, Inc. 1
UltraCrit QC Cuvettes Separation Technology, Inc. 1
UltraCrit Separation Technology, Inc. 1
UltraChek Reference Controls Normal Separation Technology, Inc. 1

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K981426 1998-05-12
K981427 1998-05-12
K981425 1998-05-12

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Stat Profile
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Nova Biomedical Corporation 510(k) number 2017-06-19 Class II Software design Software- scheduled A-QC analysis could initiate prior
to a patient result being released by the operator and result in the pending patient result being overwritten
with the A-QC test results.
179 units (US) and 904 (OUS) Total 1083 2018-08-14

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker