Automated Hematology Analyzer Poch-100i
pocH-100i (US)
3manufacturers in China registered for this device type
1catalogue number
4510(k) clearances naming this product code
1recall
Who Else Makes It
Concentrated in Guangdong (2), Jiangsu (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| VTech Communications Ltd | Dongguan | Guangdong | Contract manufacturer | 5 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| Onechipdx Biotech (Suzhou) Co., Ltd. | Suzhou | Jiangsu | Specification developer | 2 |
Record
| Listed by | Sysmex Corporation, Japan |
|---|---|
| FDA product code | GKZ |
| Device type | Counter, Differential Cell |
| Device class | Class 2 |
| Regulation | 21 CFR 864.5220 |
| Establishment | Manufacturer, Exporter |
| Record published | 2016-08-04 |
| Record revised | 2024-05-16 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 02318618 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| QBC Diagnostics | Drucker Diagnostics, LLC | 41 |
| Cell-DYN | Abbott Laboratories | 19 |
| Research and Diagnostic Systems | Research AND Diagnostic Systems, Inc. | 17 |
| Simultest | Becton, Dickinson AND Company | 10 |
| BD FACSCanto™ | Becton, Dickinson AND Company | 10 |
| FACSCanto | Becton, Dickinson AND Company | 7 |
| BD Multitest | Becton, Dickinson AND Company | 6 |
| Coulter AcT | Beckman Coulter, Inc. | 6 |
| BD™ Multi-Check | Becton, Dickinson AND Company | 6 |
| BD Tritest | Becton, Dickinson AND Company | 6 |
| Coulter LH | Beckman Coulter, Inc. | 5 |
| HemoScreen | Pixcell Medical Inc. | 5 |
Showing 12 of 245. All products under Counter, Differential Cell
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K992875 | 1999-11-09 |
| K971736 | 1997-08-26 |
| K945837 | 1995-06-09 |
| K943894 | 1995-02-03 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2014-12-18 | Class II | Device Design | There is a potential for elevated hemoglobin (Hgb) and impedance platelet count (PLT-I) values. | 1,137 units (US) 54 units (Canada) 9 inventory | 2016-07-25 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.