JAS Diagnostics

D3 Hematology Analyzer

Registry build 21.09.26
3manufacturers in China registered for this device type
1catalogue number
1510(k) clearance

Who Else Makes It

Concentrated in Guangdong (2), Jiangsu (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code GKZ
Manufacturer City Province Registered as Device types
VTech Communications Ltd Dongguan Guangdong Contract manufacturer 5
Shenzhen Mindray BIO-Medical Electronics Co., Ltd. Shenzhen Guangdong Specification developer 61
Onechipdx Biotech (Suzhou) Co., Ltd. Suzhou Jiangsu Specification developer 2

Record

Regulatory record for JAS Diagnostics
Listed by Drew Scientific, Ltd., United Kingdom
FDA product code GKZ
Device type Counter, Differential Cell
Device class Class 2
Regulation 21 CFR 864.5220
510(k) K071562
Record published 2016-09-09
Record revised 2023-08-03 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied as a kit Yes
Label carries lot or batch number
Storage Storage environment temperature 18 to 30 °C

Catalogue Numbers

Catalogue numbers for JAS Diagnostics
Catalogue number Size Status
BAS-9001-181 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
QBC Diagnostics Drucker Diagnostics, LLC 41
Cell-DYN Abbott Laboratories 19
Research and Diagnostic Systems Research AND Diagnostic Systems, Inc. 17
Simultest Becton, Dickinson AND Company 10
BD FACSCanto™ Becton, Dickinson AND Company 10
FACSCanto Becton, Dickinson AND Company 7
BD Multitest Becton, Dickinson AND Company 6
Coulter AcT Beckman Coulter, Inc. 6
BD™ Multi-Check Becton, Dickinson AND Company 6
BD Tritest Becton, Dickinson AND Company 6
Coulter LH Beckman Coulter, Inc. 5
HemoScreen Pixcell Medical Inc. 5

Showing 12 of 245. All products under Counter, Differential Cell

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K071562 2007-12-11

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of JAS Diagnostics
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
JAS Diagnostics/Drew Scientific 510(k) number 2017-04-21 Class II Material/Component Contamination May result in elevated platelet backgrounds during routine startup/background checks. 14,064 2020-01-06
JAS Diagnostics/Drew Scientific 510(k) number 2016-03-10 Class II Process control The reagent pack may result in elevated platelet background during Drew3 Hematology Analyzer routine check. 7,691 2019-08-21

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer