DxFLEX

DxFLEX Flow Cytometer

Registry build 21.09.26
1manufacturer
1catalogue number
5510(k) clearances naming this product code
7recalls on this code

Who Else Makes It

Registered in Jiangsu.

Chinese manufacturers registered for FDA product code OYE
Manufacturer City Province Registered as Device types
Beckman Coulter Biotechnology (Suzhou) Co., Ltd. Suzhou Jiangsu Specification developer 2

Record

Regulatory record for DxFLEX
Listed by Beckman Coulter, Inc., United States
FDA product code OYE
Device type Flow Cytometric Reagents And Accessories.
Device class Class 2
Regulation 21 CFR 864.5220
Establishment Contract manufacturer, Specification developer, Manufacturer, Exporter
Record published 2025-09-02

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for DxFLEX
Catalogue number Size Status
C78500 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Navios EX Beckman Coulter Ireland Inc 7
BD FACSuite Becton, Dickinson AND Company 5
BD FACSLyric Becton, Dickinson AND Company 4
FACSCanto Becton, Dickinson AND Company 4
Navios Analysis Software Beckman Coulter Ireland Inc 3
FACSuite Becton, Dickinson AND Company 3
Flow Cytometric Reagents And Accessories. Becton, Dickinson AND Company 3
BD FACSDiva Becton, Dickinson AND Company 3
Navios Beckman Coulter Ireland Inc 3
BD FACSDiva™ Becton, Dickinson AND Company 2
FACSVia Becton, Dickinson AND Company 2
Navios tetra Software Beckman Coulter Ireland Inc 1

Showing 12 of 20. All products under Flow Cytometric Reagents And Accessories.

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K232600 2023-11-22
K162897 2017-06-23
K141932 2015-04-10
K130373 2013-09-18
K121445 2013-07-26

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of DxFLEX
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Beckman Coulter, Inc. UDI-DI 2025-09-22 Class II Under Investigation by firm Due to a software error code that crashes during acquisition on patient sample when running customer defined acquisition protocol. This may lead to delayed patient results. 25 units

Recalls

6 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-01-29 Class II Software design The device may process the same sample with two different sample IDs and sample information while using the single tube loader, which has the potential for erroneous results due to the mis-identification. 288 devices 2019-06-27
2017-10-02 Class II Software design The system may duplicate sample requests leading to sample misidentification when connected to a Laboratory Information System (LIS) 268 units 2019-05-08
2017-08-21 Class II Under Investigation by firm Beckman Coulter has identified that an incorrect setting using a proprietary software configuration tool can result in the Sample Prep Probe of the AQUIOS CL drawing aspirant from the wrong tube in a cassette which manifests in incorrect va 213 units (34 units in the US) 2023-09-27
2017-04-03 Class II Other Beckman Coulter has confirmed that the Export feature located in the Results area of the AQUIOS System software is not correctly exporting Tetra Combo CRD files. 188 units total (24 units in US) 2017-08-07
2016-10-19 Class II Under Investigation by firm Beckman Coulter is recalling the AQUIOS Lyse Reagent Kit because it may lead to an increased generation of notifications and flags when used on the AQUIOS CL when running the AQUIOS Tetra application. The issue could lead to an increase in 2367 units total (207 units in US) 2017-02-24
2016-09-06 Class II Software Design Change Beckman Coulter is recalling the AQUIOS CL System because the use of the reagent carousel can lead to misalignment of the carousel and damage to the prep probe. 148 units total (12 units in US) 2017-08-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.