Xpert BCR-ABL Ultra
Xpert BCR-ABL Ultra measures BCR-ABL1 RNA relative to ABL RNA in peripheral blood from patients with diagnosed Philadelphia chromosome positive chronic myeloid leukemia. It monitors…
Xpert BCR-ABL Ultra measures BCR-ABL1 RNA relative to ABL RNA in peripheral blood from patients with diagnosed Philadelphia chromosome positive chronic myeloid leukemia. It monitors patients expressing e13a2 or e14a2 fusion transcripts during tyrosine kinase inhibitor treatment. The test reports results on the International Scale.
After initial sample preparation, a disposable cartridge runs on a compatible GeneXpert system. The instrument performs additional nucleic acid preparation, reverse transcription and quantitative real time PCR. Results include the BCR-ABL to ABL percentage and a molecular response value.
Listed Item
Xpert BCR-ABL Ultra test; 10 test kit
Test Scope
The assay does not distinguish between the two supported fusion transcript types and does not monitor other rare fusion transcripts. It is intended for monitoring and is not a test for diagnosing chronic myeloid leukemia.
Who Else Makes It
Registered in Jiangsu.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Suzhou Sniper Medical Technologies Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 4 |
Record
| Listed by | Cepheid, United States |
|---|---|
| FDA product code | OYX |
| Device type | Bcr/Abl1 Monitoring Test |
| Device class | Class 2 |
| Regulation | 21 CFR 866.6060 |
| Establishment | Contract manufacturer, Specification developer, Manufacturer, Exporter |
| 510(k) | K190076 |
| Record published | 2019-10-25 |
| Record revised | 2020-10-06 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Storage environment temperature 2 to 8 °C |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| GXBCRABL-US-10 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| MRDx BCR-ABL Test | Molecularmd Corporation | 1 |
| QuantideX qPCR BCR-ABL IS Kit | Asuragen, Inc. | 1 |
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K190076 | 2019-09-27 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Cepheid | 510(k) number | 2025-10-30 | Class II | Process design | Invitro diagnostic test kits with specimens that have elevated white blood cell count (>30,000 cell) may cause inaccurate results. | 6325 units |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2025-10-30 | Class II | Process design | Invitro diagnostic test kits with specimens that have elevated white blood cell count (>30,000 cell) may cause inaccurate results. | 4032 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.