Alinity M

Alinity m STI Application Specification File

Registry build 21.09.26
1manufacturer
4catalogue numbers in this listing
2510(k) clearances naming this product code
1recall

Who Else Makes It

Registered in Guangdong. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code QEP
Manufacturer City Province Registered as Device types
Hochuen Medical Technology Co., Ltd. Shenzhen Guangdong Contract manufacturer 20

Record

Regulatory record for Alinity m
Listed by Abbott Molecular, Inc., United States
FDA product code QEP
Device type Nucleic Acid Detection System For Non-Viral Microorganism(S) Causing Sexually Transmitted Infections
Device class Class 2
Regulation 21 CFR 866.3393
Establishment Specification developer, Manufacturer, Exporter
510(k) K202977
Record published 2022-05-19
Record revised 2025-05-21 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Single use Yes
Supplied as a kit Yes
Label carries lot or batch number, expiry date
Storage Storage environment temperature 2 to 8 °C
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Alinity m
Catalogue number Size Status
09N17-095 In distribution
09N18-001 In distribution
09N17-085 In distribution
09N17-03A In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Aptima Hologic, Inc. 5
Xpert CT/NG Cepheid 2
cobas® TV/MG Roche Molecular Systems, Inc. 2
Aptima Combo 2® Hologic, Inc. 2
cobas® TV/MG Positive Control Kit Roche Molecular Systems, Inc. 2
binx io Binx Health, Ltd. 1
Visby Medical Men’s Sexual Health Test Visby Medical, Inc. 1
BD COR CTGCTV2 US Becton, Dickinson AND Company 1

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K222379 2023-03-03
K202977 2022-04-29

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of Alinity m
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Abbott Molecular, Inc. UDI-DI 2024-09-12 Class II Device Design Abbott has identified an increase of incidences regarding Error Code (EC) 9198 (Positive control is non-reactive) while using the Alinity m HR HPV AMP Kit and Alinity m STI AMP Kit. Certain invalidated positive assay controls can be traced 15068 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer